c%,

'

.. o

,

.

,

,

.'

. .

. .

6

0CT 2 7 508

In Reply. Refer To:-

Dockets:

50-445/88-67

.

50-446/88-63

i

TU Electric

ATTN:

Mr. W. G. Counsil

' Executive Vice President

400 North Olive Street, Lock Box 81

,

Dallas,. Texas

75201

Gentlemen:

This refers to the inspection conducted by Mr. H. S. Phillips

during the period September 9 through October 4,

1988, of

activities authorized by NRC Construction Permits CPPR-126 and

CPPR-127 for the Comanche Peak Steam Electric Station, Units 1

and 2, and to the discussion of our findings with you and other

members of your staff at the conclusion of the inspection.

The enclosed copy of our inspection report idensifies areas

examined during the inspection.

Within those areas, the inspection

consisted of selective examination of procedures and representative

records, interviews with personnel, and observations by the

inspectors.

'

Within the scope of the inspection, no violations or deviations

woro identified.

In accordanco with 10 CFR 2.790 of the Commission's regulations, a

copy of this letter and the enclosed inspection report will be

placed in the NRC Public Document Room.

'

Should you have any questions concerning this inspection, we will

be pleased to discuss them with you.

Sincoroly,

ORIGINAL stCliED BY B T W^ENIC"

L

n

R. F. Warnick, Assistant Director

848

for Inspection Programs

!

l g80-

Comancho Peak Project Division

[

gg

Office of Special Projects

,

00

,

Enclosure:

!

'

dd

Inspection Repor;t 50-445/88-67; 50-446/88-63

{

~8

h4

cc w/ enclosure:

'

SeencJx page

-

55

T

RVl0 hf

12RO

(

WAO

IP:CPPDaOSP

IP:CPPD CSP

AD IP:CPPD:OSP

/

,

SPhillips

HLivormoro

RWarnick

/

!

10/>4/88

10/z7/88

10/27/88

i

i

I

,

-

-

.

.

..

-

.

,.o',0g

.

9""9W4

+*9

  1. o

UNITED STATES

.

!

g

NUCLEAR REGULATORY COMMISSION

n

%

WASHING TON. O. C. 20555

\\,,,,,,

OCT 2 71988

In Reply Refer To:

Dockets:

50-445/88-67

50-446/88-63

TU Electric

l

ATTN:

Mr. W. G. Counsil

'

Executive Vice President

400 North Olive Street, Lock Box 81

Dallas, Texas

75201

Gentlemen

This refers to the inspection conducted by Mr. H. S. Phillips

during the period September 9 through October 4, 1988, of

activities authori ed by NRC Construction Permits CPPR-126 and

CPPR-127 for the Comanche Peak Steam Electric Station, Units 1

cnd 2, and to the discussion of our findings with you and other

members of your staff at the conclusion of the inspection.

The enclosed copy of our inspection report identifies areas

examined during the inspection.

Within these areas, the inspection

,

consisted of selectivo examination of procedures and representative

records, interviews with personnel, and observations by the

inspectors.

Within the scope of the inspection, no violations or deviations

wore identified.

In accordance with 10 CFR 2.790 of the Commission's regulations, a

copy of this letter and the onclosed inspection report will be

.

(

placed in the NRC Public Document Room.

Should you have any questions concerning this inspection, we will

!

be pleased to discuss them with you.

Sincerely,

l

R Y l.U Y

R. F. Warnick, Assistant Director

for Inspection Programs

'

Comancho Peak Project Divi.sion

Office of Special Projects

'

Enclosure:

Inspection Report 50-445/88-67; 50-446/88-63

l

cc w/onclosuro:

See next page

- - -

-

.

-

I~

,,

' TU El'ectric

cc w/ enclosure:

Roger D. Walker

Nancy H. Williams

Manager, Nuclear Licensing

CYGNA Energy Services

TU Electric

Suite 390

Skyway Tower

2121 N. California Blvd

400 North Olive Street, L.B. 81

Walnut Creek, CA

94596

Dallas, TX

75201

Robert A. Wooldridge, Esq.

Juanita Ellis

Worsham, Forsythe, sampels

President - CASE

and Wooldridge

1426 South Polk Street

2001 Bryan Tower

Dallas, TX

75224

Suite 2500

Dallas, TX

75201

Susan M. Theisen

Assistant Attorney General

Mr. Homer C. Schmidt

[

Environmental Protection Division

Director of Nuclear

l

P.O. Box 12548, Capitol Station

Services

'

Austin, TX

78711-1548

TU Electric

Skyway Tower

i

Jack R. Newnin, Esq.

400 N. Olive St., L.B.

81

!

'

Newman & Holtzinger, P.C.

Dallas, TX

75201

1615 L Street, NW, Suite 1000

Washington, D.C.

20036

Mr. J. L. Vota

Westinghouse Electric

GDS Associates, Inc.

Corporation

1850 Parkway Place, Suite 720

Post Office Box 355

l

Marietta, GA

30067-8237

Pittsburgh, PA

15230

l

-

Mr. R. W.

Ackley

Lanny A. Sinkin

Stone & Webster Engineering

Christic Institute

I

Corporation Project Mgr.

1324 N. Capitol Street

CPSES

Washington, DC

20002

.

P. O. Box 1002

[

Glen Rose, Texas

76043

David R. Pigott, Esq.

Orrick, Herrington & Sutcliffe

Anthony Z. Roisman, Esq.

600 Montgomery Street

.

Suite 600

San Francisco, CA

94111

!

1401 New York Avenue, NW

Washingtca, DC

20005

Robert Jablon

Bonnie S. Blair

,

Ms. Billie Pirner Garde, Esq.

Spiegel & McDiarmid

?

Government Accountability Project

1350 New York Avenue, NW

!

Midwest Office

Washington, DC

20005-4798

!

'

104 East Wisconsin Avenue

Appleton, WI

54911

TU Electric

,

c/o Bethesda Licensing

l

Regional Administrator, Region IV

3 Metro Center, Suite 610

-

U.S. Nuclear Regulatory Commission

Bethesda, MD

20814

611 Ryan Plaza Drive, Suite 1000

Arlington, Texas

76011

i

'

- .

,,

--

.

.

.

,

U

,*

6

,

"

  • TU 'El'ectric

!

I

cc w/ enclosures

(continued)

,

George A. Parker, Chairman

!

Public Utility Committee

senior citizens Alliance of

L

Tarrant County, Inc.

i

6048 Wonder Drive

Fort Worth, ,1DC - 76133

j

Joseph F. Fulbright

<

.

Fulbright.&'Jaworski

[

1301 McKinney Street

t

Houston, TX

77010

'

William A. Burchette, Esq.

Counsel for Tex-La Electric

Cooperative of Texas

Heron, Burchette, Ruckert &

l

Rothwell

.

'

Suite 700

1025 Thoma's Jefferson St., NW

Washington, DC

20007

'

Texas Radiation Control

Program Director

Texas Department of Health

-

1100 West 49th Street

i

Austin, TX

78756

'

!

t

i

I

i

I

t

I

i

i

?

..

!

i

t

b

.

'

i

.

. .

.

. .

. .

. . .

.

0 .,

o

,o

,

.

.

.

50-445/$$~$7s 50-446/gg-4 5

1

-

l

DISTRIBUTION:

4TDidlietiYilisf(50-445/446)]'/

NRC PDR

LPDR

CPPD-JA

CPPD

tading (H(f)

OSP Reading

  • Site Reading File

R. Warnick

  • J. Wiebe
  • H. Livermore
  • MIS System, RIV
  • RSTS Operator, RIV

DRP, RIV

..

RIV Docket File

  • L.

Shea, ARM /LFMB

J. Taylor

'?

J. Partlow

C. Grimes

i

P. McKee

J. Lyons

J. Wilson

M. Malloy

J. Moore, OGC-WF

J. Gilliland, RIV

D. Crutchfield

E. Jordan

.

B. Grimes

B. Hayes

  • w/766

4

!

i

l

l

1

Y

.