_ - _ _ _ _ _ _ _ _ _ _ _

O ENCLOSURE 1 NOTICE OF VIOLATION 4

Tennessee Valley Authority Docket Nos. 50-259, 50-260, 50-296 Browns Ferry License Nos. DPR-33, DPR-62, DPR-68 The following violation was identified during an inspection conducted on March 10-12, 1986. The Severity Level was assigned in accordance with the NRC Enforcement Policy (10 CFR Part 2, Appendix C).

Technical Specification 6.3 required that detailed radiation control procedures be. prepared, approved, and adhered to.

Plant procedure BF RCI-8, Radiobioassay Program, required a current whole body count prior to entry into a contamination zone.

Plant procedure BF RCI-9, Radiation Work Permits, required current General Employee Level II training prior to entering an area requiring a radiation work permit.

Contrary to the above, during the period September 1,1985 to February 28, 1986, the licensee failed to adhere to radiation control procedures in that:

a.

Forty licensee employees entered radiation work permit areas without J

the training required by plant procedure RCI-9.

b.

Nineteen licensee employees entered contamination zones without current whole body counts as required by plant procedure RCI-8.

This is a Severity Level IV violation (Supplement IV).

Pursuant to 10 CFR 2.201, you are required to submit to this office within 30 days of the date of this Notice, a written statement or explanation in reply, including:

(1) admission or denial of the alleged violations; (2) the reasons for the violations if admitted; (3) the corrective steps which have been taken and the results achieved; (4) corrective steps which will be taken to avoid further violations; and (5) the date when full compliance will be achieved.