I MEMORANDUM To:
Steve Baggett From: Karl Von Ahn 3
Date: December 10,1998
)
{
Review of 98 Amendment to NR-345-D-104-S for Hauni Richmond's cigarette density gaugc Listed below are three comments and issues I would bring up after reviewing the document as a second reviewer.
Page 3 of SSD certificate The device's external label includes the sealed source's model and serial number. Upon replacement of a sealed source - where would a specifically licensed person acquire a replacement label containing all the correct information? Since the aluminum label is riveted onto the device -
how would the label be removed and reattached?
i Page 4 of SSD certificate j
The table for external radiation levels appears to have a conversion error in converting UR/hr to uSv/hr, The numerical value of the uSv/hr should be ten times greater than the numerical value of mR/hr not the other way around.
Page 4 of SSD certificate Under quality essurance - the word " periodic" should be replaced by the "at least once every. "
in reference to the distributor auditing the manufacturer's QA program. " Periodic" is too vague.
98-79.wpd KVA DRAFT 9904120300 990407 PDR RC PUR g
,..,