ML20205J673

From kanterella
Jump to navigation Jump to search
Further Response to FOIA Request for Records Re Seabrook Emergency Planning Sensitivity Study.Forwards App B & C Documents.App B Documents Available in Pdr.App C Documents Being Placed in PDR
ML20205J673
Person / Time
Site: Seabrook  
Issue date: 03/30/1987
From: Grimsley D
NRC OFFICE OF ADMINISTRATION (ADM)
To: Sholly S
MHB TECHNICAL ASSOCIATES
Shared Package
ML20205J677 List:
References
FOIA-87-7 NUDOCS 8704010383
Download: ML20205J673 (9)


Text

.-

f 3*g UNITED STATES 4

y p,

NUCLEAR REGULATORY COMMISSION 5

"l WASHINGTON, D. C. 20555 D

+...*

Mr. Steven C. Sholly 30 W MHB Technical Associates 1723 Hamilton Avenue, Suite K IN RESPONSE REFER San Jose, California 95125 TO F01A-87-7

Dear Mr. Sholly:

This is in further response to your letter dated December 29, 1986, in which you requested, pursuant to the Freedom of Information Act, three categories of records concerning the Seabrook Emergency Planning Sensitivity Study. My letter to you dated February 1, 1987, Appendix A, listing records being placed in the Public Document Room (PDR), 1717 H Street, NW, Washington, DC 20555, indicated that it completed action on your request. Additional records have since been located. The enclosed Appendices B and C, identify the related records. Appendix B records are already available in the PDR. Appendix C records are being placed in the PDR.

Certain records subject to your request were originated by the Federal Emergency Management Agency and are being referred to that agency for their releasability determination and direct response to you.

The search for and review of additional records subject to your request is continuing. As soon as our efforts are completed, we will notify you.

Sincerely, h

/ANP Donnie H. Grimsley, Director Division of Rules and Records Office of Administration i

l

Enclosures:

As stated 1

i 40

$ 870330 SHOLLY87-7 PDR

Re: F01A-87-7 APPENDIX B RECORDS MAINTAINED AMONG PDR FILES 1.

01/07/85 Letter to George Knighton from John DeVincentis Re:

Revised Response to Generic Letter 83-28 (Position 4.3);

Shunt' Trip Automation w/ enclosure name and address list

~

Acc. No. 8501090170 850107 2.

10/25/85 Letter to Robert Harrison from George Knighton Re: Interim Guidance on Emergency Planning Standard 10 CFR 50.47(b)(12) Regarding the Seabrook Nuclear Station, Units 1 and 2 w/ enclosure name and address list Acc. No. 8511010130 851025 3.

01/29/86 Letter to Vincent Noonan from John DeVincentis Re:

Response to Interim Guidance on Emergency Planning Standard 10 CFR 50.47(b)(12) Regarding Seabrook Station w/ enclosure name and address list Acc. No. 8602030055 860129 L

4.

02/18/86 Letter to H. Denton from George Thomas Re: Submittal by Applicants of Radiological Emergency Response Plans, State of New Hampshire and Affected New Hampshire Communities w/ enclosure name and address list l

Acc. No. 8602260328 860218 l

5.

03/00/86 Response to NRC/LLNL Review of Seabrook Station Probabilistic Safety Assessment Acc. No. 8605210289 860517 6.

03/00/86 Appendix A - Response to LLNL Draft Report Acc. No. 8605210296 860517 s

7.

03/00/86 Seabrook Station Emergency Classification System Cross i

Reference with Appendix I of NUREG-0654 l

Acc. No. 8604070105 860402 8.

03/05/86 Letter to H. Denton from Wendell Johnson Re: Radiological Emergency Response Plans, State of New Hampshire and Affected New Hampshire Communities: Additional Information w/ enclosure name and address list Acc. No. 8603110050 860305 9.

03/11/86 Letter to H. Denton from William Derrickson Re: Radio-logical Emergency Response Plans State of New Hampshire and Affected New Hampshire Communities: Additional Information w/ enclosure name and address list Acc. No. 8603130065 860311 q

i i

3 I

. ~.

i

10. 03/12/86 Letter to Vincent Noonan from John DeVincentis Re:

Additional Response to Interim Guidance on Emergency Planning Standard 10 CFR 50.47(b)(12) Regarding Seabrook Station Acc. No. 8603140058 860312

11. 03/17/86 Letter to Robert Harrison from Victor Nerses Re: Request for Additional Information - Emergency Action Levels Acc. No. 8603250327 860317
12. 04/02/86 Letter to Vincent Noonan from John DeVincentis Re:

Emergency Classification System w/ enclosure name and address list Acc. No. 8604070098 860402

13. 04/09/86 Letter to H. Denton from William Derrickson Re: Radiolog-ical Emergency Response Plans, State of New Hampshire and Affected New Hampshire Communities: Additional Information w/ enclosure'name and address. list Acc. No. 8604110996 860409
14. 04/18/86 Letter to Vincent Noonan from J. DeVincentis Re: Radio-logical Emergency Plan w/ enclosure name and address list 4

Acc. No. 8604280033 860418

15. 04/11/86 Letter to Vincent Noonan from William Derrickson Re:

Amendment 58 to the March 30, 1973 Application to Construct and Operate Seabrook Station Units 1 and 2 w/ enclosure name and address list Acc. No. 8604180161 860411 i

l

16. 04/25/86 Letter to H. Denton from George Thomas Re: Radiological l

Emergency Response Plans, State of New Hampshire and Affected New Hampshire Communities: Additional Information w/ enclosure name and address list

~

Acc. No. 8604290212 860425

17. 05/15/86 Letter to Robert Harrison from Thomas Martin Re:

j Inspection Report No. 50-443/86-18 w/ enclosure NRC j

Region I Inspection Report No. 50-443/86-18 i

Acc. No. 8605280021

18. 05/17/86 Letter to Vincent Noonan from John DeVincentis Re:

Response to NRC/LLNL Draft Review of SSPSA w/ enclosure name and address list Acc. No. 8605210279 860517

19. 05/20/86 Letter to H. Denton from William Derrickson Re: Radio-logical Emergency Response Plans, State of New Hampshire and-Affected New Hampshire Connunities: Additional Information w/ enclosure name and address list l

Acc. No. 8605230256 860520 l

20. 06/02/86 Letter to Vincent Noonan from George Thomas Re:

Amendment 59 to the March 30, 1973 Application to I

Construct and Operate Seabrook Station Units 1 and 2 w/ enclosures name and address list and Instructions for Updating Seabrook Station FSAR Amendment 59, l

Nay 1986 Acc No. 8606060195 860602 l

l

21. 06/06/86 Letter to H. Denton from William Derrickson Re: Radio-logical Emergency Response Plans, State of New Hampshire and Affected New Hampshire Communities: Additional Information w/ enclosures name and address list and RERP Notice of Revision Acc. No. 8606240074 860606
22. 06/11/86 Letter to Robert Harrison from Vincent Noonan Re: Issuance of Supplement No. 4 to the Safety Evaluation Related to Operation of the Seabrook Station, Units 1 and 2 Acc. No. 8606200242 860611 a
23. 06/13/86 Letter to H. Denton from William Derrickson Re: Radio-logical Emergency Response Plans, State of New Hampshire and Affected New Hampshire Communities: Additional l

Information w/ enclosure name and address list j

Acc. No. 8606170171 860613

24. 06/27/86 Letter to Vincent Noonan from George Thomas Re: Generic Letter 83-28; Additional Information w/ enclosure name and address list Acc. No. 8607010269 860627
25. 07/03/86 Letter to Robert Harrison from Edward Wenzinger Re:

j Inspection No. 50-443/86-20 w/ enclosure NRC Region I, Inspection Report No. 50-443/86-20 l

26. 07/16/86 Letter to Robert Harrison from Thomas Martin Re:

Inspection Report No. 50-443/86-30 Acc. No. 8607220400

27. 07/21/86 Letter to Vincent Noonan from John DeVincentis Re:

1 Seabrook Station Probabilistic Safety Assessment Update i

w/ enclosure name and address list Acc. No. 8607240181 860721

{

28. 07/29/86 Letter to Vincent Noonan from George Thomas Re: Seabrook i

Station Probabilistic Safety Assessment Update Acc No. 8607310157 i

29. 08/11/86 Note to Themis Speis to Tom Novak Re: Review of the Seabrook EPZ Submittal Acc. No. 8608190179
30. 09/10/86 Letter to Edward Markey from Lando Zech Re: Emergency Planning Zone w/ enclosures Meetings and Discussions.

Internal Meetings, Public Document, Internal Documents.

List of Calvert Cliffs Documents Acc. No. 8609230116

31. 09/15/86 Letter to Gordon Humphrey from Victor Stello Re:

j Constituent Letters w/ enclosures Nuclear Industry Safety.

Emergency Planning Issues Acc. No. 8609230053 i

)

i 1

i l

32. 09/26/86 ACRS Subcommittee on Severe Accidents and Subcommittee on Occupational and Environmental Protection Systems Acc. No. 8610090005 33.

11/03/86 Letter from Edward Markey to Chairman Zech,

Subject:

Question on Seabrook Acc. No. 8611190389

34. 11/14/86 Letter from Stello to Markey Re: Responses to Questions 1

- 19, and 21 - 24 of Markey's 11/3/86 Acc. No.

8611190375/CF 35.

12/03/86 Letter from Markey to Zech Re: Lack of Response to Markey's 11/20/86 letter Acc. No. 8612120130 36.

12/05/86 Letter from Zech to Markey Re: Request to Stop Work on BWL "Seabrook Station Probablistic Safety Assessment Update". Acc. No. 8612120108

37. 01/13/87 Letter from Markey to Zech Re: Questions on 11/18/86 Hearing on Emergency Planning Issues / Pertaining to Seabrook Acc. No. 8701200140
38. 01/14/87 Letter from Markey to Chairman Zech Re: Lack of Notice of Schedules Meetings between NRC Staff and Public Service of New Hampshire Acc. No. 8702090052
39. 01/20/87 Letter from Chairman Zech to Markey Re: Allegations of l

Drug and Alcohol Abuse at the Seabrook Construction l

Site Acc. No. 8701300213 Also, publicly available are:

A.

The Federal Register, Vol. 50, No. 98, Tuesday, May 21, 1985/ Rules & Records. Pages 20892 - 20894 B.

The Federal Register, Vol. 51, No. 44, March 6,1986/

Rules & Records.

Pages 7744-7767

Re: FOIA-87-7 Appendix C Records Maintained in the PDR Under the Request Number 1.

Undated and 5 to letter, dated 9-10-86, from Zech to Markey. Reference Appendix B, Acc. No. 8609230116 (3 pages) 2.

Undated Generic Letter 83-28 Sunnary Status (15 pages) 3.

Undated Handwritten Notes Re: ACRS (1 page) i 4.

Undated Handwritten Notes Re: Bill Sanchez (1 page) 5.

Undated NRC Staff Review of Seabrook EPZ Study (3 pages) 6.

Undated NRC Staff Presentation to the ACRS on the Review Plan for the Seabrook Emergency Planning Sensitivity Study (5 pages) 7.

Undated Distance of Intake and Discharge Structures from Mass Coast (1 page) 8.

Undated Documents Submitted by Seabrook to Update the PSA in 1986 (1 page) 9.

Undated Technical Evaluation of the EPZ Sensitivity Study for Seabrook (2 pages)

10. Undated Containment Leakage and Technical Specification Limits (4pages) 11.

10/29/86 Emergency Planning - Adequacy of Emergency Planning Zone Distances (30pages)

12. Undated Documents from the Files of Warren C. Lyon (15 pages)
13. 09/05/84 Letter to Gregory Ogeka from Robert Bernero Re: BNL Technical Assistance to the Division of Systems Integration, NRR, NRC, " Review of the Probabilistic Risk Assessment for the Seabrook Nuclear Power Plant" (3 pages) 14 09/05/84 Standard Order for DOE Work to Brookhaven Re: Review of the Probabilistic Risk Assessment for the Seabrook Nuclear Power Plant (1 page)

O i

Re: F01A-87-7

15. 09/21/84 Project and Budget Proposal for NRC Work Re: Review of the PRA for the Seabrook Nuclear Power Plant (10 pages) 16.

10/22/84 Memo to J. Funches-from Robert Bernero Re: BNL Technical Assistance to the Division of Systems Integration, Office of Nuclear Reactor Regulation, NRR, NRC

" Review of the PRA for the Seabrook Nuclear Power Plant" (1 page) 17.

10/22/84 Letter to Gregory Ogeka from Robert Bernero Re: BNL Technical Assistance to the Division of Systems Integration, Office of Nuclear Reactor Regulation, NRR, NRC

" Review of the PRA for the Seabrook Nuclear Power Plant (1 page)

18. 08/22/84 Memo to Robert Bernero from Brian Sheron Re: Advanced Funding Request for FIN No. A3778, " Review of the Probabilistic Risk Assessment for the Seabrook Nuclear Power Plant" (1 page)
19. 10/22/84 Standard Order for DOE Work Re: Review of the Probabilistic Risk Assessment for the Seabrook Nuclear Power Plant (1 page) t
20. 03/12/85 Source Terms An NRC Perspective by Robert Bernero (22 pages)
21. 04/04/85 Letter to Robert Harrison from George Knighton Re: Seabrook PSA Review w/ enclosures address list and Staff Summary Review of the Seabrook PSA (24 pages)
22. 05/08/85 Letter to Philips Ahrens from Victor Nerses Re: Meeting Notice; Docket Nos. 50-443 and 50-444 (1 page)
23. 07/15/85 Summary of FY 85 Costs - Review of PRA for Seabrook NPP (2pages)
24. 08/06/85 Letter to Gregory Ogeka from Robert Bernero Re: BNL Technical Assistance to the Division of Systems Integration, " Review of the Probabilistic Risk Assessnent for the Seabrook Nuclear Power Plant" w/ enclosures Statement of Work Modification and Standard Order for DOE Work (3 pages) 25.

12/02/85 Topics - RES 1985 Combined Third and Fourth Quarter Program l

Review (1 page) e

26. 03/17/86 Letter to Robert Harrison from Victor Nerses Re: Request for Additional Information - Emergency Action Levels w/ enclosure Comments on EALs (6 pages)
27. 04/29/86 Memo to Edward Thomas from William Lazarus Re: Clarification of Requirement for Ingestion Exposure Pathway Participation l

in Emergency Exercises (1 page)

28. 05/00/86 Handwritten Note from Jim McKnight w/ enclosure Instructions for Updating Seabrook Station FSAR (7 pages) i t

i

F01A-87-7

29. 06/11/86 Letter to Robert Harrison from Vincent Noonan Re: Issuance of Suppl. No. 4 to SER Related to Operation of the Seabrook Station, Units 1 and 2 w/ enclosure name and address list (4pages)
30. 07/29/86 Memo to Vincent Noonan from Elizabeth Doolittle Re: Forth-coming Meeting with Public Service Company of New Hampshire to Discuss Seabrook Risk Management and Emergency Planning Study w/ enclosure name and address list (3 pages)
31. 09/11/86 Memo to Public Service Co. of New Hampshire from Elizabeth Doolittle Re: Sumary of Seabrook Site Visit to Examine Various Plant Features w/ enclosure name address list (6 pages)
32. 09/12/86 Meeting Schedule - Joint Meeting of ACRS on Seabrook Station, Occupational and Environmental Protection Systems and Severe Accidents (2 pages)
33. 09/20/86 News Release from Governor Michael Dukakis (27 pages)
34. Undated Questions Re: Low Power License (8 pages)
35. 09/23/86 Handwritten Notes Re: ACRS (2 pages)
36. 09/24/86 Questions and Answers Re: Seabrook (4 pages)
37. 09/24/86 Questions and Answers Re: Chernobyl (6 pages)
38. 09/25/86 Letter to William Kerr from Paul McEachern Re: Emergency Planning Zone for Seabrook (1 page)
39. 09/25/86 Memo to Thomas Novak from Themis Speis Re: Additional Coments on the "BNL Review of Seabrook Emergency Planning Study" (3 pages)
40. 09/24/86 Handwritten Notes Re: NoonanandLong(1page) 41 09/25/86 Handwritten Notes Re: ACRS (2 pages)
42. 09/26/86 Handwritten Notes Re: Seabrook ACRS (11 pages)
43. 09/29/86 Note to B. Sheron, Z Rosztoczy, J. Lyons, H. Denton, and V. Noonan from R. Hernan Re: AIR Paper on EPZ VS Source Term (1page) 44.

10/08/86 Letter to Robert Harrison from Steven Long Re: Request for Additional Information for Seabrook Station, Units 1 and 2, Emergency Planning Sensitivity Study w/ enclosures name and address list and Request for Additional Information (7 pages)

i d

F01A-87-7 45, 10/C8/86 Handwritten Notes Re: Noonan, Nerses and Long (2 pages) 46.

10/09/86 Coments and Questions Pertinent to Emergency Planning Zone Evaluation Reactor Systems Branch (9 pages) 47.

10/15/86 Purpose and Agenda Trip to Seabrook Station and to Brookhaven National Laboratory (1 page) 48.

10/21/86 Memo to Victor Nerses from Carl Berlinger Re: Seabrook Station Risk Evaluation Pertinent to Emergency Planning (2pages) 49.

10/21/86 Technical Evaluation of the EPZ Sensitivity Study for Seabrook (2pages) 50.

10/22/86 Agenda for Briefing on Review of Seabrook EPZ Study (1 page) 51.

10/23/86 Letter to Robert Harrison from Steven Long Re: Request for Additional Information for Seabrook, Units 1 and 2, Emergency Planning Sensitivity Study w/ enclosure Request for Additional Infomation (10 pages) 52.

10/24/86 Memo to Vincent Noonan from Steven Long Re: Status of NRC Review of Seabrook Emergency Planning Sensitivity Study w/ enclosure Status of NRC Staff Review of Seabrook Emergency Planning Sensitivity Study (3 pages) 53.

10/29/86 Note to Sheldon Schwartz from Leonard Re: Chernobyl Implica-tions Assessment w/ enclosure Adequacy of EPZ Distances (11 pages) 54.

10/30/86 Memo to Raymond Fraley from Themis Sp(ets Re:1page)

Chernobyl Information for Subcomittee Review 55.

10/30/86 Handwritten Notes Re: Jane Dowdy's Preparation for Draft Report (1 page) 56.

11/03/86 Handwritten Note to Beth from Steve Long Re: Oral Questions (1 page) 57.

11/03/86 Emergency Planning and Emergency Planning Zone Chart (12 pages) 58.

11/10/86 Questions and Answers Re: Public Service of New Hampshire (60pages)

.t 59.

11/13/86 Memo to E. Fay from T. Rehm Re: Markey Subcomittee Request

'y for Notes of Seabrook Meetings (1 page) 60.

11/18/86 Note to E. Fay from T. Rehm Re: Markey Sub-Committee Request for Notes of Seabrook Meetings (1 page)

gg TECHNICAL CONSULTANTS ON ENERGY ASSOCIATES

- ^ '

1723 Harnalton Avenue-Suite K Dale G Bndenbaugh San Jose, CaMornia 95125 Rochard B. Hubbard Phone:(408) 266 2716 Gregory C. Minor 25 December 1986 FRf.EDOM OF lHf0%*eOOM Mr. Donnie H. Grimsley, Director ACT REQUEST Division of Rules and Records Office of Administration U.S. Nuclear Regulatory Commission

/

d9 Washington, D.C.

20555

/

  1. /

RE:

FOIA Request for Records Related to NRC Staff and Brookhaven National Laboratory Review of PLG-0432, PLG-0465, and NTS 1589.01

Dear Mr. Grimsley:

Pursuant to the Freedom of Information Act, please make available for public inspection and copying at the Commission's Washington, D.C., Public Document Room, records in the following categories:

A.

All records in the possession and/or control of the U.S. Nuclear Regulatory Commission which review, critique, comment upon, or otherwise discuss the Seat rook Station Risk Management and Emergency Planning Stud,y (PLG-0432, December 1985), the Seabrook Station Emergency Planning Sensitivity Study (PLG-0 465, April 19 86), and Seismic Fragilities of Structures and Components at the Seabrook Generating Station, Units 1 and 2 (NTS 1589.01, Rev. 1, NTS Engineering, June 1986).

B.

All records in the possession and/or control of the U.S. Nuclear Regulatory Commission which discuss the scope of work, funding, and manpower levels (including man-hour estimates and staffing levels) related to any reviews of the three named studies referenced in "A" above.

C.

All records in the possession and/or control of the U.S. Nuclear Regulatory Commission which discuss the validity of the results and/or which estimate the uncertainty in the results of the three named studies referenced in "A"

above.

415,54?4>eecl s

21 Mr. Donnie H. Grimsley )3' December 1986 If there are any questions concerning this request, please contact me at (408) 266-2716.

Your prompt attention to this request will be appreciated.

If the nature of your document search is such that it appears that the 10-day response time provided for in the NRC's regulations cannot be met, please pro' vide such partial responses as can be made as documents subject to this request become available for release.

Sincerely, lA 50 Steven C. Sholly Associate Consultant

l.

(

List nf Internal Documents - Seabrook 09/09/85 Notes on conference call with Nerses. Perlis and Dignan to discuss EP from Massachusetts.

10/10/85 Notes on conference call with Nerses, Perlis, Dignan, Cunningham, i

Reis, Christenbury Turk, Scinto to discuss reduction of EPZ.

j 10/11/85 Notes of conference call with Bernero, Derrickson, Nerses to discuss Seabrook approach on demonstrating ability to reduce EPZ.

07/25/86 Notes on staff meetin's with Noonan and Doolittle.

07/25/86 Notes on meeting with Bernero, Novak, Rossi, Benaroya, Noonan, Crocker.

Israel, Matthews, Perlis, Doolittle to discuss content of study.

07/29/86 Notes on staff meeting with Novak, Rossi Doolittle.

07/29/86 Notes on meeting with Jordan Doolittle, Long, Rossi Novak, Matthews, Kantor, Benaroya, Crocker to discuss cor. tent of study.

07/30/86 Notes on staff meeting with Novak, Rossi, Doolittle.

07/30/86 Notes.on staff meeting with Noonan and Doolittle to discuss plans fer August 26, 1986 meeting.

08/05/86 Notes to prepare for EDO briefing on 8/5/86.

08/06/86 Notes on meeting with T. Pratt, C. Hofmayer, Novak, Rossi, Benaroya, Doolittle, Noonan, Fioravante to discuss BNL scope of work.

08/06/86 Draft BNL Scope of Work: Review of the Emergency Planning Sensi-i tivity Study for Seabrook, Project Description.

08/06/86 Draft BNL Scope of Work: Review of the Emergency Planning Sensi-i tivity Study for Seabrook, Project Description.

08/06/86 Notes on meeting with PSNH to discuss contents of study. '

08/12/86 Notes on staff meeting with Novak, Rossi, Nocnan, Benaroya, Long, Doolittle to discuss BNL review and memo to go to Denton on status i

of review of study.

fc JA ~~ V l' 7

&kl f

6lI

4 N

2-08/12/86 Memo for Denton from Novak, Review of EPZ Sensitivity Study for Seabrook, dated 8/12/86.

08/13/86 Notes on call from David Tirrell, Wysockt, to Doolittle to discuss SeabrookStudy(AP).

Notes on calls from Judy Abel to Doolittle (Haverhill Gazzette).

Notes on call from J. Quinn (PSNH) to E. Doolittle to discuss views on scope of work.

NotesoncallfromRegionI(K. Abraham) toe.Doolittletodiscuss contents of study.

Notes on call from W. Derriksnn to E. Doolittle to discuss PSNH views on scope of work.

08/14/86 Notes on meeting held at BNL with PSNH to discuss containment strength /

aspects of the study.

08/15/86 Memo from McCreless to ACRS members dated August 15, 1986 List of ACRS Subcommittee Meetings Scheduled Through January 22, 1987.

08/19/86 Draft memo from Warren C. Lyon to Carl Berlinger Review of Seabrook Documents Pertaining to Change in Emergency Plann,ing Zone Si:e.

08/20/86 Notes on conference call with Tingle, Woodard, Fleming, Sweeny, Moody, Li to discuss consequence analysis aspect of study..

08/27/86 Notes on meeting with PSNH and BNL to discuss plant model and Event V.-

aspect of study.

08/28/86 Notes on discussion with Barrett and Doolittle regarding 08/27/85 meeting.

09/02/86 Notes on meeting with Long, Doolittle, Bagchi, Soffer, Newberry, Lyon, Tingle, Shapaker, Perlis to discuss staff's scope of wot k.

O e

  • s lt i

^

Documents Concerning EPZ Reduction at Calvert Cliffs i

r Letter from A. E. Lundvall, BG8E to NRC, " Request for EFem 1.

November 18, 1985.

" Reduction in Memorandum from H. R. Denton, NRR to G. H. Cunningham, ELD 1

11, 1985.

the EPZ for Calvert Cliffs", December 2.

MA,"Calvert Memorandum from D. B. Matthews, NRC to R.

b 18,1985.

1 l

3.

t to l

Letter from A. C. Thadant NRC to Mr. Steven Aftergood, Comit 31,1985.

4.

Bridge the Gap, December l

t Memorandum from G. H. Cunningham, ELD to H. R. Denton, N ile Plume-Cliffs Nuclear Power Plant - Recuest for Exem J

0 j

5.

l 31, 1985, Appendix E," December l

f Letter from W. J. Dircks, NRC to Congressman Roy Dyson, U.

l i

Representatives, January 3, 1986.

l 6.

t on Memorandum from T. E. Murley, Region I to H. R. Denton, N J

6,1986.

Calvert Cliffs Emergency Planning Zone Exemption Recuest". J 7.

Letter from J. A. Tiernan, BG&E to NRC, " Request for Amen 1

P.

January 10, 1986.

i in l

Memorandum from R. B. Minogue, RES to H. R. Denten, NRR 27, 1986.

Emergency Planning Zone for Calvert Cliffs", January 4

9.

l Cliffs l

Note from G. H. Cunningham, ELD to H. R. Denton, NRR, "Cal f

10.

27,1986.

14,1986.

EPZ", January Letter from H. R. Denton, NRC to J. A. Tiernan, BG&E, February 1

11.

Letter from J. A. Tiernan, BG&E to NRC, " Reduction of the E i

Planning Zone" March 27,1986.

12.

I BGAE technical memorandum, April 1, 1986.

h VA, Letter from H. R. Denton, NRC to Mr. Gary D. Knight, Falls C 13.

r 14 April 1, 1986.

i Agenda and slides from BG8E/NRC meeting, April 2, 19C6.

l Reno, Nevada, June 15 19, 1986 I

45.

Paper presented at 1986 ANS Annual Meeting,k, BG&E.

1 by J. E. Metcalf, $8W, S. Mirsky and T. Coo 16.

l f

I l

--