ML20205H986

From kanterella
Jump to navigation Jump to search
Amended Tech Spec Page 3/4 6-50 Re Secondary Ventilation Sys Automatic Isolation Dampers.Page Inadvertently Omitted from 870315 Application for Amend to License NPF-57
ML20205H986
Person / Time
Site: Hope Creek 
Issue date: 03/26/1987
From:
Public Service Enterprise Group
To:
Shared Package
ML20205H972 List:
References
NUDOCS 8704010180
Download: ML20205H986 (1)


Text

..

TABLE 3.6.5.2-1 m>

SECONDARY CONTAINMENT VENTILATION SYSTEM AUTOMATIC ISOLATION DAMPERS ISOLATION GROUP NO. 19 MAXIMUM ISOLATION TIME DAMPER FUNCTION (Seconds) 1.

Reactor Building Ventilation Supply Damper HD-9370A

+7 2.

Reactor Buf1 ding Ventilation Supply Damper HD-9370B

  • 7 3.

Reactor Building Ventilation Exhaust Damper HD-9414A

+7 4.

Reactor Building Ventilation Exhaust Damper HD-94148 de-7 c.s l

8704010180 870326 DR ADOCK 05000354 PDR HOPE CREEK 3/4 6-50

--