_

October 25, 1988 Docket No. 50-368 Pr. T. Gene Campbell Vice President,fluclear Operations Arkansas Pcwer and Light Currpany P. O. Box 551 Little Rock, Arkansas 72203

Dear Mr. Campbell:

SUBJECT:

ItiPLEPEilTAT10ti 0F THI ACTION ITEM II.K.3.5, AUTOMATIC TRIP 0F REACTOR C00LAtiT PUMPS - ARKAllSAS flUCLEAR OttE, VillT it0. 2 (GEilERICLETTER86-06)(TACfi0.49676)

We have completed our evaluation of your responses to Generic Letter 86-C6, submitted in your letters dated flovember 24, 1986 and June 3,1988, regarding reactor coolant pump trip criteria for Arkansas !!uclear One, Unit 2.

We find your responses to be acceptable, and therefore conclude that you have satisfied the requirements of TMI Action Item II.K.3.5.

Copies of our related Safety Evaluation and the EG8G Technical Evaluation are enclosed.

Sincerely,

/s/

C. Craig Harbuck, Project Manager l

Prc'ect Directorate - IV Division el Reactor Projects - III, IV, V and Special Projects Office of fiuclear Reactor Regulation

Enclosures:

1.

Safety Evaluation 2.

EGAG TER cc w/ enclosures:

See next page DISTRIBUT10ft:

r D'o3etTITe7 ' '

PNoonan ACRS (10) ilRC PDR CHarbuck LRubenstein Local POR JCalvo SWu FD4 Reading OGC-Rockville CGrires EJordan Plant File LTR NNIE: AMEtiDMEllT ANO 2 PD4/LAQ }

PD4/Pfi& M PD4/D /

PHoonht(/

CHarbuck:

JCalvo h\\

N /ME8 to/1f/88 n/Ul88

\\

8G10310194 881023 POR ADOCK 05000368 P

PDC

j akse

[',,

UNITED STATES

[

NUCLEAR REGULATORY COMMISSION aI B

i wAsHWGTON, D. C. 20666 October 25, 1988 Docket flo. 50 ~;68 fir. T. Gene Campbell Vice President, Nuclear Operations Arkansas Power and Light Company P. O. Box 551 Little Rock, Arkansas 72203

Dear Mr. Campbell:

SUBJECT:

li'PLEl'EliTAT101. OF Ti'l ACTION ITEM ll.K.3.5. AUT0ftATIC TRIP OF REACTOR COOLANT PUtPS - ARKAl:SAS NUCLEAR ONE, UNIT NO. 2 (CEllERICLETTER86-06)(TACNO.49676)

)!c have completed our evaluation of your responses to Generic Letter 86-06, submitted iri ycur letters dated flovember 24, 1986 and June 3, 1988, regarding reacter coolant pump trip criteria for Arkansas !!uclear One, Unit 2.

We find your resporises to be acceptable, and therefore conclude that you have satisfied the requirements of TMI Action Item !!.K.3.5.

Copies of our related Safety Evaluation and the EGl.G Technical Evaluation arc enclosed.

Sincerely, ttc C. Craig Harbuck, Project !!anager Project Directorate - IV Division of Reactor Projects - !!!,

!Y, Y and Special Projects Office of Nuclear Reactor Regulation

Enclosures:

1.

Safety Evaluation 2.

EGl.G TER cc w/ enclosures:

See next page 9

j,

.a t

e F

Mr. T. Gene Campbell i

Arkansas Power & Light Corapany Arkansas Nuclear One, Unit 2 cc:

Mr. Dan R. Howard, Manager Mr. Charles B. Brinkman, Manager Licensing Washington Nuclear Operations Arkansas Ituclear One C-E Power Systems P. 0.-Box 608 7910 Woodmont Avenue i

Russellville, Arkansas 72801 Suite 1310 I

Bethesda, Maryland 20814 j

tir. James it. Levine, Executive Director i

Site Nuclear Operations Honorable William Abernathy Arkansas liuclear One County Judge of Pope County P. O. Box 608 Pope County Courthouse Russellville, Arkansas 72801 Russellville, Arkansas 72801 Mr. llicholas S. Reynolds'

- Bishop, Cook, Percell & Reynolds 1400 L Street, !!.W.

Washington. 0.C.

20005-3502 Regional Administrator, Region IV U.S. Nuclear Regulatory Comission Office of Executive Cirector for Operations 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 Senior Resident Inspector U.S. l;uclear Regulatory Corcraission 1 Huclear Plcnt Road Russellville, Arkansas 72801 Ms. Greta Dieus, Director Division of Environraental Health Protection Arkansas Departner,t of Health 4815 West Markan Street Little Rock, Arkansas 72701

!!r. Robert B. Borsum Babcock & Wilcox Nuclear Power Generation Division 1700 Rockville Pike, Suite 525 Rockville, Maryland 20852