Person / Time
Site: Prairie Island  
Issue date: 08/12/1986
From: Norelius C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Larson C
NORTHERN STATES POWER CO.
References
IEB-85-003, IEB-85-3, NUDOCS 8608180386
Download: ML20205E507 (2)


Text

,.-

AUG I 2 1986 i

Docket No. 50-282 Docket No. 50-306 Northern States Power Company ATTN: Mr. C. E. Larson Vice President of Nuclear Generation 414 Nicollet Mall Minneapolis, MN 55401

\\

Gentlemen:

The preliminary review of your initial response to IE Bulletin 85-03

" Motor-0perated Valve Common Mode Failures During Plant Transients Due To Improper Switch Settings" indicates that it does not contain an adequate description of the program to assure valve operability as requested by Action Item e of the Bulletin. The program description in your response is little more than a paraphrase of the Bulletin's requirements. Additional information is requested within one month of receipt of this letter.

Responses may be submitted as specified in IE Bulletin 85-03, page 6, i.e.:

"The written reports shall be submitted to the appropriate Regional Administrator under oath or affirmation under provisions of Section 182a, Atomic Energy Act of 1954, as amended. Also, the original copy of the cover letters and a copy of the report shall be transmitted to the U.S. Nuclear Regulatory Commission Document Control Desk, Washington, DC 20555 for reproduction and distribution."

uestions addressing this issue may be forwarded to Richard J. Kiessel, IE 301)492-8119.

Sincerely, Charles E. Norelius, Director Division of Reactor Projects l

See Attached Distribution lh f

ejke rer

'RIIJ I

RII RIII B

rq s

He f(

Et8/N2 N s

8/

6

/P ffpff gfy {('L g G i

F603180386 860812

,O DR ADOCK 0500 2

_gy

. i AUG 12 1985 C. E. Larson.

Distribution cc:

E. L. Watzl, Plant Manager DCS/RSB (RIDS)

Licensing Fee Management Branch Resident Inspector, RTII Prairie Island Resident Inspector, RIII Monticello John W. Ferman, Ph.D.,

t Nuclear Engineer, MPCA 4

9

_ _, -....., -.