yT
[ preg D
NUCLEAR REGULATORY COMMISSION
o
"
y
REGION ll
g
y
,j
101 MARIETTA STREET,N.W.
- i
e
ATLANTA, GEORGI A 30323
\\,
/
AUG O 7 fo86
+...+
-
Report Nos.:
50-280/86-16 and 50-281/86-16
Licensee:
Virginia Electric and Power Company
P. O. Box 26666
Richmond, VA 23261
Docket Nos.:
50-280 and 50-281
License Nos.:
Facility Name:
Surry 1 and 2
Inspection Condu- d:
uly 7-11, 1986
Inspector:
/
VCk
f/f')b
Y$hh
A.TiTiman,fhyticalsecurityInspector
Date Signett
Approved
by: bl
tM
Q [36 M6.
.
D.
R.
McGuireM Chief, Physic 41( }Secdrity Section
Date Signed
Nuclear Materials Safety and SafWguards Branch
Division of Radiation Safety and Safeguards
SUMARY
Scope:
This unannounced physical security inspection included a review and
examination of the licensee's:
Security Plan and Implementing Procedures;
Management Effectiveness - Security Program; Security Organization; Physical
Barriers - Vital Areas; Compensatory Measures; Assessment Aids; Access Control -
Personnel; Detection Aids
Protected Area; and Personnel Training and
-
Qualification - General Requirements.
Results:
The licensee was found to be in compliance with regulatory
requirements in the areas inspected with the exception of the following:
Failure to provide adequate intrusion detection capability for the protected
area.