ML20205D486
| ML20205D486 | |
| Person / Time | |
|---|---|
| Site: | Vogtle |
| Issue date: | 07/29/1986 |
| From: | Brownlee V NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| To: | |
| Shared Package | |
| ML20205D492 | List: |
| References | |
| 50-424-86-25, 50-424-86-56, NUDOCS 8608180055 | |
| Download: ML20205D486 (1) | |
Text
..
UNITE 3 STATES
' * /ge# #84g 'o NUCLEAR REGULATORY COMMISSION
',d
.[
o R EGION 11 g
j 101 MARIETTA STREET, N.W.
ATLANTA. GEORGI A 30323
/
Report Nos.:
50-424/86-56 and 50-425/86-25 Licensee: Georgia Power Company P. O. Box 4545 Atlanta, GA 30302 Docket Nos.:
50-424 and 50-425 License Nos.: CPPR-108 and CPPR-109 Facility Name: Vogtle 1 and 2 InspectionConducyd: June 16-20, 1986 Ins ector:
so u M b^
7 W. P. Kle1Morge
'Date AigrTed Accompanying Perso el:
._t. Jones PE, Ph.D. EG&G - Idaho, Inc.
/
-l Or c
s App ove by:
M
~,asow n/
7/ _
d (-,
J.'J. BlikY, Section Chief
/ Date Signed Engineering Branch
[
Division of Reactor Safety
SUMMARY
Scope:
This special announced inspection involved in the areas of licensee actions on previous enforcement matters (92701B) (92702B), housekeeping (548348),
material identification and control (429028), material control (429408), and review of readiness review module 18A heating ventilating and air-conditioning (HVAC).
Results:
No violations were identified. One deviation was identified - Failure to revise FSAR as committed, paragraph 3a.
C600100055 060729 PDR ADOCK 05000424 0
PDR I
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _