Text

-------- ---- -- -------- ---- -------- ---------------b U.S. NUCLEAR REGULATORY CcMMISS12N I

m % eis CERTIFICATE CF COMPLIANCE I

inne to cmi FOR RADIOACTIVE MATERIALS PACKA0ES

[

NUMBER D REVISION NUMBER

c. PACKAGE IDENTIFICATION NUMBER d PAGE NUMBER
e. TOTAL NUM8ER RAGES I

1.e.CERTIF$W1 4

USA /9181/B(U) 1 2

I I

racAuste I
a. This certefecate is issued to certify that the packaging and contents desenbed in item 5 below, meets the applicable safety standards set forth in Title 10. Code.

l cf Federal Regulations. Part 71," Packaging and Transportation of Radioactive Material."

I I

b. This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other I

apphcabie reguistory agenc es. inciuding the government of any country through or into which the package will be transported.

I I

l 3 rsisggriggs;ssjuty Tse sAsis or A sArcry ANAtysis Regigt,Ngggsysgoga pygioN

}

I I

I Nuclear Packaging, Inc.

Nuclear Packaging, Inc. application dated I

1010 South 336th Street dated March 31, 1983, as supplemented.

l Federal Way, WA 98003 711 181 b

^

l

c. ooexer NuMeeR
  • 9

~

to is conditional upon fulfiHing the requ te.rr rits of 10 CFR Part 71. as apphcable, and the conditions specified below.

c

, 3, 7

I s.

3 f

(a) Packaging i

e.,

.' s I

(1) Model Nos.: PAS;2 and PAS-2A I-I t

M f

l (2) Description a

L Thefpackaging consists of an outer overpack, inner overpack, optional

[

i l

secondary containment. vessel (Model_No. PAS-2A), sample, shield, and a E

I sample vial.' ' The outer foam filled-overpack is constructed identical

[

l to the Model.xNo. N-55 love'rpack;(Docket.No. 71-907D), 32" OD x 48" high.

~

g I

The ' inner overpack consists (ofda; Department of Transportation Speciff-t l

cation,17H steel! drum linedIwith rigid polyurethane foam cut to fit t

the outside 'dimens' ions of-the' secondary containment vessel. The t

i i

optional'secondarf"coritainment' vessel'is: fabricated from carbon or

[

l stainless steel'(17.7" OD x 24 3/4" high)'and is provided with a Viton L

I 0-ring and>eight, 5/16" cap screws. The secondary containment vessel l

I is equipped +with a test port. The sample shield consists of a lead g

l filled steel weldment (16.5" OD x 22.75" high)/provided with four t

shielded wall penetrations and a shielded lid'(all gasketed with Viton p

i l

0-rings). The 3-3/,4"-ID x 8-1/4" high sample shield cavity contains a E

I valved sample vial surrounded by absorbent vermiculite and lead shot.

I I

The vial may contain about 50 milliliters of liquid (reactor coolant

[

I water sample). The gross weight of the package is approximately 2,400 e

pounds.

[

i (3) Drawings I

i (h

I The packages are constructed in accordance with Nuclear Packaging, Inc. Drawing Nos.: X-20-220D, Sheets 1 through 4, Rev. G and X l lI l

200D, Rev. C.

l I

I f

l 8703300309 870324 PDR ADOCK 07109181 g

I C

PDR p

3 i

~ ' '

~'#*"#'*""**

~

CONDITIONS (continued) 1 Pagm 2 - Certificate No. 9181 - Revision No. 4 - Docket No. 71-9181 5.

(b) Contents (1) Type and form of material Radioactive material in the fonn of liquid coolant sample obtained from a reactor coolant system.

(2) Maximum quantity of material per package 50 milliliters with a thermal heat load not to exceed 3.0 watts.

6.

In addition to the requirements pf gSubparttGyof 0 CFR Part 71, each package prior to first use must meet the acc'ptance tbsts and fjteria specified in Section 8.1, e

must be maintained in accordadce' with Section 8.,4pg prepared for shipment in accordance with Section.7.0'of the application. The sample vial must be annually leak tested to the repirements of LT-12 (Appendix 8.3.*2g tance in NUPAC's test, Assembly Helih, Sniffer Test for the 7.

The statement of acc NUPACPAS-2 Packaging (5>1(LT-16,Rev.2, March,941984) must be replaced by the following acceptance criter.f aQFor each assembly /tojhave an, acceptably low leagage rate, the detection @quipinentraust)befcapable of detecting a leak of criteria prior t6dfirst use risin'oti acc'.le'akage\\ratidreater thali)the acceptance 10 scc /sec or sinaller. Anyfddtec' ed t

eptable.)

~

(v Z N f"~~T (jtC j:4 Prior to first u'se of eachlpackfge.jtherleakLtes'tispec/,ified aT Notes 8 and 14 on L.-

l 8.

s Drawing No. X-20L220D, Rev! G must.be 'pbefo'rined?as Teg/uired.< '

MN "

dji s i { {i s:

}:

C#

r 9.

The package authorized by this5 certificate is,herebyf approved for use under the

^

3 general license provisions!of 10sCFR 971.12., '7:d pf s,-

u-y";

,, a

(

l Q'[

10. Expiration date: Marchfl,1989.

s

. p.

'/

, REFERENCES N

s,

,-4

ym Nuclear Packaging, Inc. application dated. March 31, 1983.

Supplements dated: September 9, 1983; February 17, March 9, and December 19, 1984; April 9,1985; June 2,1986; and February 11, 1987.

l :

FOR THE U.S. NUCLEAR REGULATORY COMMISSION 644 L4 Charles E. MacDo Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety, NMSS Date:

MAR 3 4 W h

-_____________________w_-__##________________________;

p "8 Eg-

+

~e UNITED STATES

[

k NUCLEAR REGULATORY COMMISSION' 5

j WA5HINGTON, D. C. 20566

~s.,...../

Transportation Certification Branch A) proval Record Model Nos.

)AS-2 and PAS-2A Package Docket No.' 71-9181 By application dated June 2, 1986, Nuclear Packaging, Inc. requested that the certificate of compliance be amended to reference the latest revision of packaging drawings. The appifcant has revised Drawing No. X-20-220D, Sheets 1 through 4, Revision G to add an optional valve operator guard that separates the lead shot from the valve operator.

The NRC staff agrees with the applicant that this change has no effect on the package's ability to meet the requirements of 10 CFR Part 71.

W

^ Charles E. MacDo a d, Chief Transportation Certification Branch Division of Fuel Cycle and

l Material Safety, NMSS Date:

MAR 2 4 M7 l

l l

l l