NPDES Noncompliance Notification:On 850816,high Ph Discovered While Draining Steam Generator.Possibly Caused by Ammonia Used During Outage to Prevent Steam Generator Degradation
ML20205C685
Person / Time
Site: Cook  
Issue date: 09/10/1985
From: Will Smith
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
NUDOCS 8509230101
Download: ML20205C685 (2)


Text

l9 o

' IND NA & MICHIGAN ELECTRIC COMPANY C?HLl'"M' DONALD C. COOK NUCLEAR PLANT

, ff [L P.O. Box 458, Bridgman, Michigan 49106 my

- + ;

(616) 465-5901

7

?

!>~

Q}

eni September 10, 1985 (7 _h D " 3-II Mr. J.G. Keppler, Regional Administrator United States Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, IL 60137 Operating License DPR-58/74 i

Docket Nos. 50-315/50-316

Dear Mr. Keppler:

Pursuant to the requirements of Appendix B, Part II, Nonradiological, Environmental Protection Plan, Section 3.2, a copy of the report to the Michigan Water Resources Commission notifying them of a high pH while draining the steam generator on August 16, 1985, is cttached.

This report is required by Amendment No. 54 to Facility Operating License No. DPR-58 and Amendment No. 40 to Facility Operating License No. DPR-74 dated May 6, 1982.

j Sincerely, as/*----

M W.G. Smith, Jr.

Plant Manager

/bab Attachment cc:

John E. Dolan g92j0 ji5 M.P. Alexich g

PDR R.F. Kroeger H.B. Brugger R.W. Jurgensen NRC Resident Inspector R.C. Callen, MPSC G. Charnoff, Esq.

j J.M. Hennigan i

SEP1ojgg$

H.R. Denton, NRC rz J.F. Stietzel Dottie Sherman, ANI Library l

INPO PNSRC l g

-r h JC A.A. Blind hja.th

SW

@,*LINDIANA &_ MICHIGAN ELECTRIC COMPANY C NE SUMMIT SoVARE, P o box 60. FORT WAYNE. IN 46801 Tesoprone (219) 425-2111 RICHARD C. MENGE August 26, 1985 Vice President Paul D. Zugger, Executive Secretary Michigan Water Resources Commission Stevens D. Mason Building, Box 30026 Lansing, Michigan 48909

Dear Mr. Zugger:

RE: Donald C. Cook Nuclear Plant NPDES Permit No. 0005827 Steam Generator Blowdown Anticipating a return to service af ter a maintenance outage, the Number 23 steam generator in the Unit 2 nuclear steam supply system was drained. A grab sample of the effluent was found to have a pH of 10.63.

The elevated pH is likely due to the addition of ammonia used during the outage to prevent steam generator degradation.

Very truly yours, i

l:

Richard C. Menge Vice President RCM/df c:

W. G. Smith I certify under penalty of law that I have personally examined and am f amiliar with the information submitted on this and all attached documents; and based on my inquiry of those individuals immediately responsible for obtaining the information, I believe the submitted information is true, accurate and complete.

I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment.

$_ L A $.

(F Richard C. Menge