ML20204G563

From kanterella
Jump to navigation Jump to search
Provides Simulation Facility Certification Four Yr Rept, Identifying Uncorrected Performance Test Failures & Providing Schedule for Correction of Failures.Plant Procedure SO23-XXI-3.1.2 Simulator...Scheduling Encl
ML20204G563
Person / Time
Site: San Onofre  Southern California Edison icon.png
Issue date: 03/12/1999
From: Scherer A
SOUTHERN CALIFORNIA EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20204G565 List:
References
NUDOCS 9903260180
Download: ML20204G563 (3)


Text

..

f 4... ~

h5 A. Edward Scherer s '

SOUllflRN Calif 0RNIA t!""=6.m, EDISON an uns<>s mumlow c%

March 12,1999 U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555

Subject:

Docket Nos. 50-361 and 50-362 Simulation Facility Certification Four Year Report San Onofre Nuclear Generating Station, Units 2 and 3

Reference:

1. Letter R. M. Rosenblum (SCE) to Document Control Desk (NRC),

" Simulation Facility Certification, San Onofre Nuclear Generating Station, Units 2 and 3," dated March 22,1991

)

i

2. Letter, W.C. Marsh (SCE) to Document Control Desk (NRC),

" Simulation Facility Certification Four Year Report, San Onofre Nuclear Generating Station, Units 2 and 3 " dated February 24,1995 l

By letter dated March 22,1991, Southern California Edison (SCE) submitted i

the Simulation Facility Certification letter as required by 10 CFR 55.45(b) (5) (i). In j

accordance with 10 CFR 55.45(b) (5) (ii), SCE is required to " Submit, every four years on the anniversary of the certification, a report to the Commission which identifies any uncorrected performance test failures, and submit a schedule for correction of such performance test failures, if any." This letter provides the report due on March 22,1999 (Attachment).

' All performance testing scheduled between March 22,1995 and March 22,1999 has been completed, and there is no uncorrected performance test failure for the simulator.

Thus, a correction schedule is not needed.

10 CFR 55.45(b) (5) (vi) requires that a certification report *..must include a description of performance ter, ting completed for the simulation facility, and must include a description of the performance tests, if different, to be conducted on the simulation facility during the subsequent four-year period, and a schedule for the conduct of f

approximately 25 percent of the performance tests per year for the subsequent four years."

9903260180 990312 P PDR ADOCK 05000361 R

PDR j P. O. Box 128 San Clemente. CA 926744)128 949-368-7501

~ Fax 949-368-7575

Documsnt Cohtrol Desk March 12,1999 San Onofre procedure, SO23-XXI-3.1.2, " Simulator Performance Test Scheduling,"

included in the Attachment, describes the performance testing completed since March 22,1995. SCE will use the schedule in this procedure for required simulator performance testing for the upcoming four-year period.

If you have any questions regarding this subject, please let me know.

Sincerely, Attachment cc:

E. W. Merschoff, Regional Administrator, Region IV J. L. Pellet, Chief, Operations Branch, NRC Region IV J. W. Clifford, NRC Project Manager, San Onofre, Units 2 & 3 (w/ enclosures)

J. A. Sloan, NRC Senior Resident inspector, San Onofre, Units 2 & 3 (w/o enclosures) i i

. -.