ML20204F944
| ML20204F944 | |
| Person / Time | |
|---|---|
| Site: | Catawba |
| Issue date: | 06/03/1982 |
| From: | Parker W DUKE POWER CO. |
| To: | Adensam E, Harold Denton Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML20204F949 | List: |
| References | |
| NUDOCS 8305020326 | |
| Download: ML20204F944 (2) | |
Text
F DUKE POWER COMPANY Powra 13camixo 402 Sourn Gnuacu Srneer, Cruumire. N. C. ana4a WI L LI AM O. PA R M E R. J R.
v.c,e....or,
June 3, 1982 tctc -o c:^ ca 7o4 Strans PaoowcTion 373-4083 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Attention: Ms. E. G. Adensam, Chief Licensing Branch No. 4 Re:
Catawba Nuclear Station Docket Nos. 50-413 and 50-414
Dear Mr. Denton:
Elinor G. Adensam's letter of May 4,1982 requested additional information in regards to containment pressure boundary fracture toughness. Attached is Duke Power Company's response.
Very truly yours, n
_- 6
)
William 0. Parker, Jr.
ROS/php Attachment cc: Mr. J. P. O'Reilly Mr. P. K. Van Doorn Mr. R. Guild Palmetto Alliance Mr. J. L. Riley Mr. H. A. Presler i:
$ actShlo col
- 7g,MS/C A
8305020326 820603 PDR ADDCK 05000413 A
O
- O CATAWBA NUCLEAR STATION CONTAINMENT PRESSURE B0UNDARY FRACTURE TOUGHNESS DATA
- 1) Fabrication Code a) Containment Vessel Plate: ASME Code 1971 Edition through Summer 1972 addenda, Subsection NE, paragraph NE-2350 b) Containment Vessel Welds: ASME Code (as above), Subsection NE, paragraph NE-4335 c) Personnel Locks: ASME Code (as above), Subsection NE, paragraph 2350 d)
Equipment Hatch: ASME Code (as above), Subsection NE, paragraph NE-2300 e) Piping Penetrations: ASME Code 1974 Edition through Summer 1974 addenda, Subsection NC, paragraph NC-2311
- 2) Materials Test Data:
In storage at the Catawba site *
- 3) Lowest Service Metal Temperatures Item Specification Actual Charpy Test U
U Containment plates OF 49 F
-30 F-Containment welds 10 49
-20 Personnel Locks 48 49 18 Equipment Hatch 0
49
-30 Piping Penetrations (stubends) 10 49
-30
- 4) As-Built Information for Flued Heads This data is given on the following drawings.
Penetration Drawing Type I CNM-1206.00-0010 Type II CNM-1206.00-0011 Type III Ser 1 CNM-1206.00-0012 Type III Ser. 3 CNM-1206.00-0048 d