Text

-

FEB 02 M3 Docket No.

99900403/82-03 General Electric Company Nuclear Energy Business Operations ATTN:

Mr. W. H. Bruggeman Vice President and General Manager 175 Curtner Avenue San Jose, CA 95125 Gentlemen:

This refers to the inspection conducted by Mr. D. D. Chamberlain of this office on June 28-July 1, and July 13-15, 1982, of your facility at San Jose, California, and to the discussions of our findings with Mr. A. Breed and members of your staff at the conclusion of the inspection.

This inspection was conducted to evaluate the General Electric Company's handling of a former employee's concerns regarding Mark III containment design issues with respect to 10 CFR Part 21 reporting requirements and to determine if the GE design process requirements were implemented in the disposition of the issues.

During this inspection it was found that you failed to meet certain commit-ments in your Topical Report No. NED0-11209-04A.

The specific findings and references to the pertinent requirements are identified in the enclosures to this letter.

Please provide us within 30 days from the date of this letter a written state-ment containing: (1) a description of steps that have been or will be taken'to correct these items; (2) a description of steps that have been or will be taken to prevent recurrence; and (3) the dates your corrective actions and pre-ventive measures were or will be completed.

Consideration may be given to extending your response time for good cause shown.

The response requested by this letter is not subject to the clearance pro-cedures of the Office of Management and Budget as required by the Paperwork Reduction Act of 1980, PL 96-511.

l RIV CI: RSS SC:RSS BC:VPB D:EISid, RA: RIVp DDChamberlain/rf CJHale UPotapovs EHJohnson JTCollt 8/17/82 8//1 /82 8//7/82

.8/)/82

-8/F/52 7

-c8 rc sa Yjfwjy ya 96 8305020289 830202 PDR GA999 ENVGENE 99900403 PDR

r

.i c 6

General Electric Company In accordance with 10 CFR 2.790 of-the Commission's regulations, a copy of this letter and the enclosed inspection report will be placed in the NRC's Public Document Room.

If this report contains any information that you believe to be exempt from disclosure under 10 CFR 9.5(a)(4), it is necessary that you (a) notify this office by telephone within 10 days from the date of this letter of your intention to file a request for withholding; and (b) submit within 25 days from the date of this letter a written application to this office to withhold such information.

If your receipt of this letter has been delayed such that less than 7 days are available for your review, please notify this office promptly so that a new due date may be established.

Consistent with Section 2.790(b)(1), any such application must be accompanied by an affidavit executed by the owner of the information which identifies the document or part sought to be withheld, and which contains a full statement of the reasons on the basis which it is claimed that the information should be withheld from public disclosure.

This section further requires the statement to address with specificity the considerations listed in 10 CFR 2.790(b)(4).

The information sought to be withheld shall be incorporated as far as possible ireto a separate part of the affidavit.

If we do not hear from you in this regard within the specified periods noted above, the report will be placed in the Public Document Room.

Should you have any questions concerning this inspection, we will be pleased to discuss them with you.

Sincerel),

OdC f Sg 3 Sn d b' s

/

l u POTAPO/S" Uldis Potapovs, Chief Vendor Program Branch

Enclosures:

1.

Appendix A - Notice of Nonconformance 2.

Appendix B - Inspection Report No. 99900403/82-03 3.

Appendix C - Inspection Data Sheets (8 Pages) l l

bcc:

IE Files AE00 NRC:PDR QAB Reg. Administrators, I, II, III, IV, V EHJohnson, RIV w