Forwards IE Bulletin 78-12A,suppl to IE Bulletin 78-12. W/Encl ANO:7811300055
ML20204C889
Person / Time
Site: Monticello, Prairie Island  
Issue date: 11/24/1978
From: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Wachter L
NORTHERN STATES POWER CO.
References
NUDOCS 7812050278
Download: ML20204C889 (1)


Text

.

.4,

...~L.

.-M~,--~.L-

<--s i

a

.m a p#

UNITED STATES 8

t 4

NUCLEAR REGULATORY COMMISSION yj

,, d[,, g R EGION ill g

799 ROOSEVELT ROAD e

y,,

OLEN ELLYN,ILLINol8 60137 Docket No. 50-263 NOV 2.4.378

~

Docket No. 50-282 Docket No. 50-306 Northern States Power Company ATTN:

Mr. Leo Wachter Vice President Power Production and System Operation 414 Nicollet Mall Minneapolis, MN 55401 Gentlemen:

Enclosed is a supplement (lE Bulletin No.78-12A) to IE Bulletin No. 78-12 which requires action by you with regard to your power reactor facilities with an operating license or a construction permit.

Should you have any questions regarding this Bulletin or the actions required by you, please contact this office.

l Sincerely, pp er Director

Enclosures:

1. IE Bulletin 78-12A j
2. List of IE Bulletins Issued in 1978 cc w/encls:

Mr. L. R. Eliason, Plant Manager j

Mr. F. P. Tierney, Jr.,

Plant Manager Central Files Director, NRR/DPM Director, NRR/ DOR PDR Local PDR NSIC TIC Anthony Roisman, Esq.,

Attorney John W. Ferman, Ph.D.

Nuclear Engineer 781aos oT73 GL i

..__J.-..

i.

I U.S. NUCLEAR REGULATORY COMMISSION I

OFFICE OF INSPECTION AND ENFORCEMENT REGION 111 November 24, 1978 IE Bulletin No.78-12A ATYPICAL WELD MATERIAL IN REACTOR PRESSURE VESSEL WELDS Description of Circumstances:

This Bulletin is a supplement to IE Bulletin 78-12, issued on September 29, 1978, and the two documents should be considered together.

Bulletin 78-12 described the use of weld wire that failed to meet all specified chemical properties in welds of twelve identified reactor pressure vessels. Use of the atypical weld material in vessel weldments causes them to have higher than normal nil-ductility transition te'rperature characteristics which in turn requires more conservative pressure / tempera-ture operating limits.

Bulletin 78-12 was issued for the purpose of verifying that similar atypical veld tr.aterial was not also supplied to other vessel manufacturers and used in reactor pressure vessel fabrication. Recognizing that the scope of the record review required is extensive and time consuring, and to assure that responses provided are meaningful, the requirements of Bulletin 78-12 are being nodified.

Action To Be Taken By Licensees and Permit Nolders:

For all power reactor facilities with an operating license or a c.onstruction permit, except those already identified as possibly having 9 typical weld :.aterial.1/

i l

he twelve nuclear units identified as having possible atypical pressure vessel veldsents are: Three Mile Island Unit Nos.' I and 2,

-- - Crystal River Unit No. 3, Arkansas Nuclear One Unit No.1, Oconee

. Unit No. 3, Rancho Seco Unit No.1, Midland Unit No.1. Quad Cities

.e Unit No. 2 Browns Ferry Unit No.1, Turkey Point Unit No. 4 and Zion Unit Nos. I and 2.

0 e 4 k

9

.f

.,_j'%

f iOO 1

'7?

r y

T

.r

a f

1 IE Bulletin No.78-12A 2-November 24, 1978

,1 Provideellinformationavailableonveldmateria{/susedforeach 1.

reactor vessel primary boundary ferritic weldmente (Items Ic, Id, 2a, 2b, first sentence of 2c, 3 and 4 of Bulletin 78-12.) This I

information may be provided to NRC through the vessel manufacturers or suppliers as appropriate to prevent duplication of data.

2.

Correlation of specific heat, lot or batch to specific weldments in specific vessels is not required at this time.

(Last sentence of Item 2c, Bulletin 78-12.) However, each licensee is required to verify that the veld materials information provided to the NRC under Item 1 does in fact cover each reactor vessel for which the licensee is responsible.

3.

Responses to item 1 above shall be submitted in writing within 120 days of the date of this Bulletin supplement. Reports should be submitted to the Director of the appropriate NRC Regional Office and a copy should be forwarded to the U.S. Nuclear Regulatory Commission, Office of Inspection and Enforcement, Division of Reactor Construction Inspection, Washington, D.C.

20555.

Approved by GAO, B180225 (R0072);' clearance expires 7/31/80. Approval was given under a blanket clearance specifically for identified generic problems.

'1/ Veld material information submitted will be evaluated by NRC. ' Requests for further information will be dependent upon results of these evalus-tions. Additional requests or instructions will be issued following

'hese evaluations.

t

-m- - - -

v t avgww e up.

+=wi c'

e e r w e p's

< r v' y.

e w 4

W E4

lpl J

-l 1

'?

i IE Bulletin No.78-12A Date: November 24, 1978 LISTING OF IE BULLETINS ISSUED IN 1978 i

Bulletin Subject Date Issued Issued To No.

78-01 Flammable Contact -

1/16/78 All Power Reactor Arm Retainers in G.E.

Facilities with an CR120A Relays OL or CP 78-02 Terminal Block 1/30/78 All Power Reactor Qualification Facilities with an OL or CP j

78-03 Potential Explosive 2/8/78 All BWR Power Gas Mixture Accumula-Reactor Facilities tions Associated with with an OL or CP BWR Offgas System i

Operations I

78-04 Environmental Quali-2/21/78 All Power Reactor fication of Certain Facilities with an Stem Mounted Limit OL or CP Switches Inside Reactor Containment 78-05 Malfunctioning of 4/14/78 All Power Reactor Circuit Breaker Facilities with an Auxiliary Contact OL or CP Mechanism-General Model CR105X 78-06 Defective Cutler-5/31/78 All Power Reactor Hammer, Type M Relays Facilities with an With DC Coils OL or CP 78-07 Protection afforded 6712/78 All Power Reactor by Air-Line Respirators Facilities with an and Supplied-Air Hoods OL, all class E and F Research Leactors with an OL, all Fuel Cycle Facilities with an OL, and all Priority' 1 Material Licensees

~

Page 1 of 2 A

4 w.p

,,qq, e, 5%

    • w w= W +.****+^

~

3 O

1

' i, IE Bulletin No.78-12A Date: November 24, 1978 LISTING OF IE BULLETINS ISSUED IN 1978 Bulletin Subj ect Date Issued Issued To No.

78-08 Radiation Levels from 6/12/78 All Power and Fuel Element Transfer Research Reactor Tubes Facilities with a Fuel Element transfer tube and an OL.

i 78-09 BWR Drywell Leakage 6/14/78 All BWR Power Paths Associated with Reactor Facilities Inadequate Drywell with an OL or CP Closures 78-10 Bergen-Paterson 6/27/78 All BWR Power Hydraulic Shock Reactor Facilities Suppressor Accumulator with an OL or CP Spring Coils 78-11 Examination of Mark I 7/21/78 BWR Power Reactor Containment Torus Facilities for Welds action: Peach Bottom 2 and 3, Quad Cities 1 and 2, Hatch 1, Monti-cello and Vermont Yankee 3

78-12 Atypical Weld Material 9/29/78 All Power Reactor in Reactor Pressure Facilities

  • th an Vessel Welds OL or CP 78-13 Failures in Source Heads 10/27/78 All General and of Kay-Ray Inc., Cauges Specific Licensees Models 7050, 7050B, 7051 with Kay-Ray Gauges 7051B, 7060, 7060B, 7061 and 7061B

~

Page 2 of 2 i

.'