| Site: | Callaway |
| Issue date: | 04/17/1986 |
| From: | Randolph G UNION ELECTRIC CO. |
| To: | James Keppler NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| References | |
| 86-02, 86-2, ULNRC-1299, NUDOCS 8605090148 | |
| Download: ML20203Q237 (2) | |
Text
E
.47/M g
{ T l i T p1
. _~_ l UNION ELECTRIC COMPANY ULNRC-1299, d
P
~
~
Conomy Plant April 17, 1986 t~
~
t diYW Mr. James G. Keppler Regional Administrator
.e@png Office of Inspection & Enforcement U.S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, IL 60137 DOCKET NUMBER 50-483 CALLAWAY PLANT UNIT I FACILITY OPERATING LICENSE NPF-25 CALLAWAY PLANT POSITIVE MODERATOR TEMPERATURE COEFFICIENT SPECIAL REPORT 86-02
Dear Mr. Keppler:
This report is submitted pursuant to the requirements of Callaway Technical Specification 3.1.1.3.a.
On April 15, 1986 during the conduct of initial Low Power Physics Tests, a positive moderator temperature coefficient of 0.01 pcm/*F was measured per procedure ESP-ZZ-00009, Moderator Temperature Coef ficient Measurement at Zero Power. Low power physics testing continued sub-sequent to this measurement in accordance with Special Physics Test Exception Specification 3.10.3.
Following measurement of isoth'rmal temperature coefficient with Bank D inserted and with Banks D and C inserted, and measurement of bank worths for Control Banks C and D, interim bank withdrawal limits have been determined. These withdrawal limits have been conservatively established to ensure a Moderator Temp-erature Coef ficient of - 1 pcm/*F is maintained. These limits are provided as Attachment 1 to this report. The burnup necessary to re-store a negative Moderator Temperature Coefficient under the most limiting plant conditions (Hot Zero Power, All Rods Out, No Xenon) has been calculated to be 4000 MWD /MTU. This core average burnup carresponds to a Boron Concentration of 1430 pps at the conditions stated and has been calculated to yield a Moderator Temperature Coefficient of - 1 pcm/*F.
The rod withdrawal limits included as Attachment I will be imposed until a core burnup of 4000 MWD /MTU has been achieved.
8605090148 860417 PDR ADOCK 05000483 S
PDR G. L. Randolph Manager, Callaway Plant GLR /WRC/KDA/KRB/ crc g
Attachment gI cc:
USNRC Resident Inspector, Callaway Executive Director, SNUPPS (h
USNRC Licensing Proj ect Manager Manager, Electric Department, J
g\\
M u ic vice Commission Maihng Address: PO. Box 620 Futton, MO 65251 APR 2 81986
FIGURE 2-13 ETP-ZZ-00014 CONTROL R0D WITHDRAWAL LIMITS TO MAINIAIN MIC < 0 EFFECTIVE UP TO 4000 MWD /M U BURNUP, CYCLE 2 I
i s
r i
i a
I g
N 8
N ~S a
a w
z h N
h I
i gm z
- o
= -
o o M W i
i A M
~#
- o 3
1 i
e
,c I
L M"
{
100%
~ ~
.5 t
C Y
La s
/
,o
{
90 f
a s
N g
C 6
1
}
80%
.y i
r
,o 0
1 s
w t
/
t s
r 70%
s
/
.o
_o e
e A
60%
/
s
./
V
/
/
-8 50% --
f
/
1
/
/
8 a
40%
f f
h t
! O 7-
- 8
/-
~
/
3 e
30%
Z W
- ~
g z
20%
o
~
~
f f
a u
t
- F o
m zo 10%
^
s i
f f
g I
HZP I
i O
W z
o J
O 4
cQ N
d i
4 O
3 W
O M
I JJ
+
N
{
i l
I l
m m
e m
m e
m U
N N
N N
m m
.-e N
N N
N m
m m
Q N O
c N
as q
N N
m m