ML20203K026

From kanterella
Jump to navigation Jump to search

Forwards SER of 980130 Relief Request PR-10,rev 1,requesting one-time Relief from ASME Requirements for Performing Class 1 Inservice Sys Pressure Test at Full Sys Pressure of 1005 Psig
ML20203K026
Person / Time
Site: Cooper 
Issue date: 02/26/1998
From: Hannon J
NRC (Affiliation Not Assigned)
To: Horn G
NEBRASKA PUBLIC POWER DISTRICT
Shared Package
ML20203K030 List:
References
TAC-MA0677, TAC-MA677, NUDOCS 9803040432
Download: ML20203K026 (3)


Text

_ _ _ - - - _ _ _ _ _ _

Mr. O R. Hom -

Febru:ry 26, 1998 l

- Sr. Vice Presiderti of Energy Supply

- Nebra9e Prhlic Power District 1414 im Street Cel.nts, NE 68601

SUBJECT:

EVALUATION OF REQUEST FOR RELIEF PR-10, REVISION 1. FOR COOPER NUCLEAR STATION (TAC NO. MA0677)

Dear Mr. Hom:

By letter dated January 9,- 1998, the Nebrasics Public Power District (NPPD) submitted Relief Request PR 10, associated with the Third 10-Year interval inservice inspection (ISi) Program for the Cooper Nuclear Station (CNS). NPPD submitted Revision 1 to PR-10 by lotter dated January 30,1998. -in your letters, you raquested relief from certain requirements in Section XI of the Ar9erican Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code.

Specifically, you requested a one-time relief from the ASME requirements for performing a Class -

1 inservice system pressure test at the full system pressure of 1005 psig. The test will be required as a result of planned modifications to 8 Main Stesin safety / relief valves during a mid--.

cycle outage currently scheduled to begin on February 27,1998.-

The staff, with technical assistance from its contractor, the Idaho National Engineering and m

l Environmental Laboratory (INEEL), has completed its review of the information provided in support of Request for Relief PR-1'. The results of our review are documented in the enclosed safety evaluation (Enclosure 1). The staff concludes that for Request for Relief PR-10, Code compliance will result in hardship or unusual difficulty without a compensating increase in quality and safety. Therefore, the staff concludes that the altemative contained in Request for Relief PR-10 is authorized pursuant to 10 CFR 50.55a(a)(3)(ii).-

- A copy of the Technical Letter Report prepared by INEEL is provided as Enclosuu 2. If you have any questions, please contact Mr. James R. Hall at (301) 415-13E Sincerely, Jo n

$in n,

re or Project Directorate IV-1 Division of Reactor Projects I!!/IV Office of Nuclear Reactor Regulation Docket No. 50-298

Enclosures:

1. Safety Evaluation
2. INEEL Technical Letter Report cc w/encis: See next page r- -

- -~ " q;u

,k&$ DU hw a a +S %

' DISTRIBUTION:

Docket File PUBLIC PD4-1 r/f CHawes ACRS OGC (15B18)

TGwynn, FaV JHall EAdensam (EGA1) lg1.,' g,, q l

my JHannon GBagchi TMcLellan pg; Document Name: COOA0677.REL OFC PM/PD4-1 LA/PD4-1 PD/PDN OGC NAME JHall/vw Chaw s JHankr[

@)Ytcuco DATE 7-/N98 M/98

/98 1/ 1 5/98 hES[NO)

YES/NO YES/NO YES/NO YES/NO OFF CIAL RECORD COPY j

9303040432 980226 PDR ADOCK 05000298 f-PDR

paaeeg g

i UNITED STAM.S 1

NUCLEAR RECULATCRY COMMISSION WAFMINGToN. D.c. 30006-4001 February 26, 1998

- Mr. G. R. Hom Sr. Vice President of Energy Supply Nebraska Public Power District 141415th Street Columbus, NE 68601

SUBJECT:

EVALUATION OF REQUEST FOR RELIEF PR-10, REVIS:ON 1 FOR COOPER NUCLEAR STATION (TAC NO. MA08T/)

Dear Mr. Hom:

By letter dated January 9,1998, the Nebraska Public Power District (NPPD) submitted Relief Request PR-10, associated with the Third 10-Year Interva.1 Inservice inspection (ISI) Program for t5e Cooper Nuclear Station (CNS). NPPD wbmitted Revision 1 to PR-10 by lotter dated January 30,1998, in your letters, you iequested relief from certain requirements in Section XI of the American Society of Mechanical Engineers (ASME) Boile. and Pressure Vessel Code.

Specifically, you requested a one time relief from the ASME requ!roments for performirig a Class l

1 inservios system pressure test at the full system pressure of 1005 psig. The test will bo required as a result of planned modifications to 8 Main Steam safety / relief valves during a mid.

l cycle outage currently scheduled tc begin on February 27,1998.

The staff, with technical assistance from its contractor, the Idaho National Engineering and Environmental Laboratory (INEEL), has completed its revie,w of the information provided in support of Request for Relief PR 10. The results of our review are documented in the enclosed e

safety evaluation (Enclosure 1). The staff concludes that for Request for Relief PR-10, Code compliance will result in hardship or unusual difficulty without a compensating increase in que.lity ead safety. Therefore, the staff concludas that the sitemative c.ontained in Request for Relief PR 10 is authorized pursuant to 10 CFR 50.55a(s)(3)(ii).

A copy of the Technical Letter Report prepared by INEEL is provided as Enclosure 2. If you have any questions, please contact Mr. James R. Hall at (301) 415-1336.

Sincerely, John N. Hannon, Director Project Dir3cterule IV-1 Division of Reactor Projects lil/IV Office of Nuclear Reactor Regulation Docket No. 50 238

Enclosures:

1. Safety Evaluation
2. INEEL Technical Letter Report cc w/encis: See next page l

N

Mr. O. R. Hom Nebraska Public Power Distr;ct Cooper Nuclear Station oc:

Mr. John R McPhell, General Counsel Lincoln Electric Syste.'

Nebraska Public Power District ATTN: Mr. Ron stoddard P. O. Box 499

- Box 80869 Columbus, NE 60602-0499 Lincoln, NE 23501 Nebraska Public Power Disuict MidAmerican Energy ATTN: Mr.~J. H. Swailes ATTN: Dr. William D. Leech, Manager-Nuclear Moe President of Nuclear Energy.

907 Walnut Street P. O. Box 98 P. O. Box 657 Brownville, NE 68321

- Des Moines, lA-50303-0657 Randolph Woud, Director Nebmska Department of Environmental

. Nebraska Public Power District Contral ATTN: Mr. B. L. Houston, Nuclear P. O. Box 9d922 Licensing & Safety Manager.

Lincoln, NE 68509-8922 P. O. Box 96 Brownville, NE $8321 l

Mr. Larry Bohlken, Chairman l

Nemaha County Board of Commissioners l

Nemaha County Courthouse i

18'!4 N Street Aubum, NE 68305 Senior Resident inspector

. U.S. Nuclear Regulatory Commission P. O. Box 218 Brownville, NE 68321 -

Regional Administrator, Region IV U.S. Nuclear Regulatciy Commission =

611 Ryan Plaza Drive, Suita 1000 Arington,TX 76011 Ms. Cheryl Rogers, LLRW Program Manager Division of Radiological Health Nebraska Department of Heshh 301 Centennial Mall, South P. O. Box 95007 Lmcoln, NE 68509-5007 Mr. Ronald A. Kucera, Department Drector ofIntergovemmental Cooperation Department of Natura! Resources

- P.O. Box 176 Jefferson City, MO 65102 g

N fB 1%

-