ML20203F711

From kanterella
Jump to navigation Jump to search
Forwards SER Re Review of 831105 & 850821 Responses to Generic Ltr 83-28,Items 4.2.1 & 4.2.2.Responses Acceptable. W/O Encl
ML20203F711
Person / Time
Site: Braidwood  
Issue date: 04/21/1986
From: Noonan V
Office of Nuclear Reactor Regulation
To: Farrar D
COMMONWEALTH EDISON CO.
References
GL-83-28, NUDOCS 8604250296
Download: ML20203F711 (1)


Text

APR 2 1 ggy Docket Nos.:

STN 50-456 and STN 50-457 Mr. Dennis L. Farrar Director of Nuclear licensing Commonwealth Edison Company P.O. Box 767 Chicago, Il 6069('

Dear Mr. Farrar:

SUBJECT:

GENERIC LCTTER 83-28:

ITEMS 4.2.1 AND 4.2.2 By letters dated November 5, 1983 and August 21, 1985, you respor.ded to Generic letter 83-28 Items 4.2.1 and 4.2.2 for Braidwood Station, Units 1 and 2.

The staff, with assistance from Idaho National Engineering laboratory, has reviewed your responses and found them acceptable for the subject items.

The results of our review are contained in the enclosed Safety Evaluation Report.

Vincent S. Noonan, Director PWR Project Directorate No. 5 Division of PWR licensing-A

Enclosure:

As stated cc: See next page Distribution:

L. 01shan J. Partlow PD#5 Rdg. File B. Grimes DocketiFiles.

OE NRC"PDR AC S!(10) local PDR M.

shbrook T. Novak J.

tevens E. Jordan L.

1shan

, g PM:PD#5 DIR:PD#

Y Ol01shan:js V. Noo

(

04/16 /86 04/

6 0FFICIAL RECORD COPY 8604250296 860421 PDR ADOCK 05000456 A

PDR