ML20203E226
| ML20203E226 | |
| Person / Time | |
|---|---|
| Issue date: | 01/21/1998 |
| From: | Blough A NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | Sanford C AFFILIATION NOT ASSIGNED |
| References | |
| NUDOCS 9802260284 | |
| Download: ML20203E226 (3) | |
Text
1 4
JAN 21 1998 Mr. Craig P. Sanford President SMI East Coast Medical Waste, Inc.
1307 South Pennsylvania Avenue Morrisville, Pennsylvania 19067-1275
SUBJECT:
NRC INSPECTION CONDUCTED ON DECEMBER 31,1997
Dear Mr. Sanford:
On December 31,1997, Judy Joustra and Sheri Arredondo, of this office, conducted a safety inspection at the above location, of activities that occurred following a tritium contamination event on October 29,1997, at the Arthur Brisbane Child Treatment Center, in Farmingdale, New Jersey. The inspection consisted of observations by the inspectors, interviews with you, examination of transportation records and contamination surveys.
From this inspection, we understand that, on December 4,1997, you removed 60,55-gallon drums containing tritium contaminated waste from Arthur Brisbane. You delivered one drum, containing a broken tritium exit sign, to your Morrisville facility and the remaining drums were shipped to Chambers Medical Technologies, located in South Carolina. You contacted the Isollte Corporation and obtained instruction for tiansfer of the broken exit sign to isolite. Isolite instructed you to remov she exit sign from the drum and place it in a box for shipping. You removed the sign frc,m the drum and delivered the sign to Isolite on December 12,~1997. The empty drum, that had previously held the broken exit sign, is stilllocated at your facility.
The inspectors obtained wipe samples from various locations at your facility. These locations include the 55 gallon drum, adjacent floor and workbench, and the floor and steering wheel of the van used to transport the sign to Isolite. The wipes wsre analyzed by the NRC Region I anstytical laboratory. The results of our analysis are enclosed for your review. Results indicate that tritium contamination exists inside the drum used to transport the broken sign from the Brisbane facility to your facility in Morrisville, Pennsylvania. Action is needed in order to either decontaminate the drum or to transfer the drum to an authorized recipient. Note that decontamination activities are restricted to individuals working under an NRC or Agreement State license authorizing this activity.
I 0FRCIALPICORDCOPY e# nng 9802260284 980121 M
PDR STPRG ESGPA BD!'",', j\\
PDR V
b l
O e
Mr. C. P. Sanford 2
The NRC may have further questions or concerns related to this event. This inspection regarding the Arthur Brisbane tritium contamination event and subsequent disposal is considered open. Thank you for your cooperation during this matter.
Sincerely, ORIGINAL SIGNED BY:
GEORGE C. PANGBURN A. Randolph Blough, Director Division of Nuclear Materials Safety License No. Non-Licensee
Enclosure:
NRC Wipe Test Results cc:
State of New Jersey Commonwealth of Pennsylvania DOCUMENT NAME: S:\\Pending\\SMI.SUV To receive e copy of this docu sent, indcate in the box:
'N' = No copy "C" = Copy without attachment / enclosure "E" = Copy with attachment / enclosure 0FFICE DNMS/RI DNMS/RI DNMS/RI,d,7, l
s NAME JJoustra GW JJohansen %ur ARBlougtF#1 DATE 01/13/98 01/IQ /98 v l01/cQ)/98 V 01/
/98 01/ /98 0FFICIAL RECORD COPY n
ENCLOSURE RESULTS OF NRC WIPE TESTS TAKEN ON DECEMBER 31. 1997 AT SMI EAST C0AST MEDICAL WASTE. INC.
LOCATION TRIT:UM (H-3)
DPM PER WIPE
]
Outside surface of lid of 55-gallon drum 90 Outside side surface of 55-gallon drum 9
Floor adjacent to 55-gallon drum 89 Workbench behind the 55-gallon drum 24 Floor about 4 feet from the 55-gallon drum 90 jnsidesurfaceoflidandsidewallof55-gallondrum 4.9 E3 Floor near rear of transport van 67 Steering wheel of transport van 99 Floor near mid-section of transport van 43