U.S. NUCLEAR REGULATORY COMMISSION April 1986 0

'r, 0FFICE OF NUCLEAR REGULATORY RESEARCli Division 3 o

.. m Task CE 301-4 o,

f DRAFT REGULATORY GUIDE AND VALUE/ IMPACT STATEMENT

Contact:

W.R. Pearson (301)443-7663 STANDARD FORMAT AND C0 FOR THE SAFETY ANALYSIS FOR ONSITE STORAGE OF SPENT E CASKS O

O S

s This regulatory guide and the associated value/lopact statement are bef ag issued in draf t fore to involve the pubitc in the early stages of the development of a regulatory posillon in this area. They have not received complete staf f rettew and do not represent an of ficial hRC staf f position.

Public corsnents are being solicited on both draf ts, the guide (including any implementation schedule) and the value/ impact statement.

Coeuments on the value/ impact statement should be accompanied by supporting data. Written co.mnents may be

N submitted to the Rules and Procedures granch. der, Auft. U.S. Nuclear Regulatory Coannission. Washtngton, OC 20555. Coment s may also be delivered to Room 4000. 'taryland National Bank Building. 7735 Old r,corg, town #oad, tethesda. *%ryland from i/

8 :15 a.m. to 5:00 p.m.

Copies of concents received may be erasined at the Pet Pubitt Docuwnt Poom,1717 H 5treet NW.,

d Washington, DC.

Coments util be most helpful if received by June 16, 1986.

Requests for single copies of draft guldes (which may be reproduced) or for placement on an automatlC distribution list for single copies of future draf t guides in specific divisions should be apde in writing to the U.S. Nuclear eelutatory Coanntssion.

Washington, DC 20555. Attention: Director, Division of Technical Information and Document Control.

8604230198 860430 PDR REGGD inXXXR PDD

TABLE OF CONTENTS Page INTRODUCTION.

vii Chapter 1 INTRODUCTION AND GENERAL DESCRIPTION OF STORAGE SYSTEM.

1-1 1.1 Introduction 1-1 1.2 General Description of Location.

1-1

1. 3 General Storage System Description.

1-2 1.4 Identification of Agents and Contractors 1-2

1. 5 Material Incorporated by Reference 1-2 Chapter 2 SITE CHARACTERISTICS.

2-1 2.1 Geography and Demography of Site Selected.

2-1 2.1.1 Site Location.

2-1 2.1.2 Site Description.

2-1 2.1. 3 Population Distribution and Trends.

2-2 2.1.4 Uses of Nearby Land and Waters.

2-2 l

2.2 Nearby Industrial, Transportation, and Military Facilities.

2-3 2.3 Meteorology.

2-3 2.3.1 Regional Climatology.

2-4 2.3.2 Local Meteorology.

2-4 2.3.3 Onsite Meteorological Measurement Program 2-5 2.3.4 Diffusion Estimates 2-5 2.4 Hydrology.

2-5 2.5 Geology and Seitz.;!ogy 2-6 2.5.1 Basic Geologic and Seismic Information.

2-6 2.5.2 Vibratory Groun'. Motion 2-7 2.5.3 Surface Faulting.

2-7 2.5.4 Stability n' Subsurface Materials 2-8 2.5.5 slope Stability 2-8 Chapter 3 PRINCIPAL CASK DESIGN CRITERIA.

3-1 3.1 Purpcses of Cask 3-1 3.1.1 Spent Fuel To Be Stored 3-1 3.1.2 General Operating Functions.

3-1 i

1ABLE OF CONTENT $ (Continued)

O P_ age 3.2 Design Criteria for Environmental Conditions and 3-1 Natural Phenomena..

3.2.1 lornado and Wind Loadings 3-2 3.2.2 Water Level (Flood) Design..

3-2 3-3 3.2.3 Seismic Design.

3.2.4 Snow and Ice Loadings.

3-3 3-3 3.2.5 Combined Load Criteria..

3-4 3.3 Safety Protection Systems..

3.3.1 General.................

3-4 3.3.2 Protection by Multiple Confinement Barriers and 3-4 Systems.

3.3.3 Protection by Lquipment and Instrumentation Selection.

3-4 3-5 3.3.4 Nuclear Criticality Safety.

3-5 3.3.5 Radiological Protection.

3.3.6 Fire and Explosion Protection.

3-6 3-6 3.3.7 Materials Handling and Storage.

3-6 3.4 Summary of Storage Cask Design Criteria.

l 4-1 Chapter 4 510 RAGE SYSIEM......

4-1 4.1 Location and Layout.

4-1 4.2 Storage Site 4-1 4.2.1 Structures..

4-2 4.2.2 Storage Site Layout.

4.2.3 Storage Cask Description...

4-2 4-3 4.2.4 Instrumentation System Description..

4-3 4.3 Transport System 4-4 4.3.1 Function.

4-4 4.3.2 Components.

4.3.3 Design Bases and Safety Assurance..

4-4 4-4 4.4 Operating Systems.

4-5 4.4.1 Loading and Unloading System..

4.4.2 Decontamination System.

4-5 4.4.3 Storage Cask Repair and Maintenance.

4-6 4.4.4 Utility Supplies and Systems.

4-6 4.4.5 other Systems.

4-6 e

ii

TABLE OF CONTENTS (Continued)

Page

4. 5 Classification of Structures, Systems, and Components..

4-7 4.6 Decommissioning Plan.

4-7 Chapter 5 STORAGE SYSTEM OPERATIONS..................

5-1 5.1 Operation Description.

5-1 5.1.1 Narrative Description..

5-1 5.1. 2 Flowsheets.

5-2 5.1. 3 Identification cf Subjects for Safety Analysis.

5-2 5.2 Control Room and Control Areas 5-2 5.3 Analytical Sampling.

5-3 Chapter 6 WASTE MANAGEMENT.

6-1 Chapter 7 RADIATION PROTECTION...

7-1 7.1 Ensuring That Occupational Radiation Exposures Are As low As Is Reasonably Achievable (ALARA).

7-1 7.1.1 Policy Considerations and Organization....

7-1

)

7.1.2 Design Considerations.

7-1 7.1. 3 Operational Considerations...

7-2 7.2 Radiation Sources.

7-2 7.2.1 Characterization of Sources..

7-2 7.2.2 Airborne Radioactive Material Sources.

7-2 7.3 Radiation Protection Design Features.

7-3 7.3.1 Storage System Design Description.

7-3 7.3.2 Shielding.

7-3 7.3.3 Area Radiation and Airborne Radioactivity Monitoring Instrumentation.

7-4 7.4 Estimated Onsite Collective Dose Assessment.

7-4 7.5 Health Physics Program.

7-4 7.5.1 Organization.

7-4 7.5.2 Equipment, Instrumentation, and Facilities.

7-4 7.5.3 Procedures.

7-4 7.6 Environmental Monitoring Program 7-5 Chapter 8 ACCIDENT ANALYSES.

8-1 8.1 Of f-Normal Operations..

8-1 111

TABLE OF CONTENTS (Continued)

P.agg 8-2 8.1.1 Event.

8.1. 2 Radiological Impact from Off-Normal Operations..

8-3 8-3 8.2 Accidents.

8-4 8.2.1 Accidents Analyzed.

8.3 Site Characteristics Affecting Safety Analysis 8-6 9-1 Chapter 9 CONDUCT OF OPERATIONS 9-1 9.1 Organizational Structure 9-1 9.1.1 Co porate Organization.

9.1. 2 Operating Organization, Management, and 9-2 Administrative Control System 9-2 9.1.3 Personnel Qualification Requirements.

9.1. 4 Liaison with Other Organizations.

9-3 9-3 9.2 Preoperational Testing and Operation 9.2.1 Administrative Procedures for Conducting Test 9-3 Program 9.2.2 Test Program Description.

9-4 9-4 9.2.3 Test Discussion 9-4 9.3 Training Program 9.4 Normal Operations.

9-5 9-5 9.4.1 Procedures..

9.4.2 Records 9-5 9-5 9.5 Emergency Planning.

9-5 9.6 Physical Security Plan.

10-1 Chapter 10 OPERATING CONTROLS AND LIMITS.

10.1 Pr'cosed Operating Controls and Limits.

10-1 10.1.1 Content of Operating Controls and Limits.

10-2 10.1.2 Bases for Operating Controls and Limits 10-2 10.2 Development of Operating Controls and Limits.

10-2 10.2.1 Functional and Operating Limits, Monitoring Instruments, and Limiting Control Settings.

10-3 10.2.2 Limiting Conditions for Operation 10-3 10.2.3 Surveillance Requirements.

10-3 10-4 10.2.4 Design Features iv

TABLE OF CONTENTS (Continued)

=

10.2.5 Administrative Controls.

10-4 10.2.6 Suggested Format for Operating Controls and Limits.

10-4 Chapter 11 QUALITY ASSURANCE.........

11-1 DRAFT VALUE/ IMPACT STATEMENT...

VI-1 I

i f

f v

INTRODUCTION Section 72.15, " Content of Application:

Technical Information," of 10 CFR Part 72, " Licensing Requirements for the Storage of Spent Fuel in an Independent Spent Fuel Installation (ISFSI)," requires that a safety analysis report. (SAR) be included with an application for a license under Part 72.

Regulatory Guides 3.44, " Standard Format and Content for the Safety Analysis Report for an Independent Spent Fuel Storage Installation (Water-Basin Type),"

and 3.48, " Standard Format and Content for the Safety Analysis Report for an Independent Spent Fuel Storage Installation (Dry Storage)," supply guidance for preparing an SAR if the installation is not located at the site of a licensed reactor.

This draf t regulatory guide supplies guidance for preparing the SAR if the installation is collocated with a civilian nuclear power reactor and spent fuel storage casks are used.

Much of the information requested in this guide may be available in docketed material previously submitted by an NRC li-l censee.

This information may be contained in an SAR submitted under a reactor license or in a topical safety analysis report (TSAR) submitted by a vendor and approved by the staff under NRC's Topical Report Review Program.* Clear and specific reference to material that has been previously submitted and approved by NRC ir. the appropriate sections of the guide (e.g., information requested in Chapters 2 and 3) may be adequate (see also Section 1.5 of the guide).

The infor-mation requested in some sections of the guide (e.g., Sections 3.2, 3.3, 7.1, 7.3, 9.1, 9.3) may be simplified or shortened by reference, with supplemental information on how existing plans and programs will be applied to the proposed spent fuel storage system.

In most, if not all, cases the cask used for the storage of spent fuel will be one that has been analyzed for safety and approved by NRC under its.opical Report Review Program.

The cask TSAR submitted under this program analyzes the cask design and fabrication in relationship to natural phenomena and other site-related conditions.

As long as site-specific conditions

  • A related draft regulatory guide (Task CE 306-4) entitled " Standard Format and Content for a Topical Safety Analysis Report for a Dry Spent Fuel Storage Cask" is being issued for comment at approximately the same time as this draft guide.

vii

are within the scope of the cask TSAR analyses, there is no need for additional site-specific reviews and approvals by NRC.

It is suf ficient to show that site-specific conditions are within the envelope of the TSAR evaluations.

Consulta-tion with the NRC staff is encouraged when preparing the SAR for the onsite storage of spent fuel in casks.

This guide sets forth a format that is acceptable to the NRC staff for the SAR required for the license application to store spent fuel in accordance with 10 CFR Part 72.

Conformance with this Standard Format is not mandatory.

License applications with differing SAR formats will be acceptable to the staff if they provide an adequate basis for the findings required for the issuance of a license.

However, because it may be more difficult to locate needed informa-tion in a nonstandard format, the staff review time may be longer.

Any information collection activities mentioned in this draft regulatory guide are contained as requirements in 10 CFR Part 72, which provides the regulatory basis for this guide.

The information collection requirements in 10 CFR Part 72 have been cleared under OMB Clearance No. 3150-0132.

I 1.

Purpose, Applicability, and Use of This Standard Format This Standard Format has been prepared to identify for applicants the type of information needed in the SAR and to facilitate an orderly review.

The SAR serves as the principal technical communication between the applicant and the NRC.

It establishes the nature of the spent fuel storage system and the plans for its use.

The SAR should describe the onsite spent fuel storage system (excluding the reactor pool storage capability).

This system should include the cask storage site, the facilities for loading and unloading the cask, and the onsite trans-port of the cask.

Since the reactor pool will probably be used for the loading

~

and unloading of the cask, only those areas directly affected by these opera-tions need be discussed.

This discussion would normally be centered on methods of reducing impacts on the reactor system and interfaces between systems.

l viii

In the SAR, the applicant should analyze the storage system in terms of additional potential hazards that could result from the spent fuel storage system and the means employed to protect against these hazards, including the associated margins of safety.

This includes evaluating l

l a.

Radiation shielding, l

b.

Confinement and control of radioactive materials, c.

Vulnerability of storage casks to accidents, d.

Projected quantities and concentration of radioactive materials in effluents, e.

Treatment of effluents containing radioactive materials, f.

Reliability of components and systems that are important to safety, and g.

The radiological impact associated with normal operations, off-normal conditions, and accidents.

The SAR should demonstrate the degree of skill, care, and effort used by the applicant in planning all aspects of the project.

The applicant may provide i

a complete, in-depth analysis of some subjects in supplemental reports or topical reports and incorporate them into the SAR by reference.

A detailed presentation on the conduct of operations should be included in the SAR covering a.

Normal operation, b.

Emergency plans,

{

c.

Organizational structure, d.

Personnel qualifications, e.

Quality assurance, f.

Operator training, g.

Reactor systems interfaces, h.

Management and administrative policies, procedures, and controls, i.

Proposed license conditions, including technical specifications, and j.

Decommissioning plan.

7 ix

2.

Supplemental Information Because of the diversity of storage cask designs, the age of the fuel to be stored, and other storage conditions, the applicant may wish to include appendices to the SAR to provide detailed supplemental information not explicitly identified in this Standard Format.

The following are examples:

a.

Supplementary information regarding assumed analytical models, cal-culational methods, or design alternatives used by the applicant or its agents with particular emphasis on rationale and detailed examples used to develop the bases for criticality safety, b.

Technical information in support of new or novel design features, and c.

Reports available to the applicant such as cask TSARS, which are submitted by cask vendors for NRC approval.

3.

Proprietary Informatiun Proprietary information should be submitted separately.

When submitted, it should be clearly identified and accompanied with the applicant's detailed reasons and justifications for requesting its being withheld from public disclosure, as specified by 6 2.790, "Public Inspections, Exemptions, Requests for Withholding," of 10 CFR Part 2, " Rules of Practice for Domestic Licensing Proceedings."

4.

Style and Composition The applicant should strive for clear, concise presentation of the information provided in the SAR.

Information requested in more than one section may be cross-referenced and need not be repeated.

The SAR should follow the numbering systems of this Standard Format at least down to the level of subsections.

l

References, including author, date, and page number, should be cited within the text if this is important to the meaning of the statement.

References used should appear either as footnotes to the page where referenced or at the end of each chapter.

A table of contents and an index of key items should be included in each volume of the SAR.

Where numerical values are stated, the number of significant figures given should reflect the accuracy or precision to which the number is known.

Where appropriate, estimated limits of errors or uncertainty should be given.

Abbreviations should be consistent throughout the SAR and should be consistent with generally accepted usage.

Any abbreviations, symbols, or special terms not in general use or unique to the proposed storage system should be defined when they first appear in the SAR.

Graphic presentations such as drawings, maps, diagrams, sketches, and tables should be employed where the information may be presented more adequately or conveniently by such means.

Due concern should be taken to ensure that all information so presented is legible, that symbols are defined, and that drawings are not reduced to the extent that visual aids are necessary to interpret pertinent items of information.

These graphic presentations should be located with the section in which they are primarily referenced.

5.

Physical Specifications 1

a.

Paper size (1) Text pages:

8 x 11 inches.

(2) Drawings and graphics:

8 x 11 inches preferred; however, a larger size is acceptable provided the finished copy when folded does not exceed 8 x 11 inches.

xi

b.

Paper stock and ink.

Suitable quality in substance, paper color, and ink density for handling and reproduction by microfilming or image-copying equipment.

c.

Page margins.

A margin of no less than 1 inch should be maintained on the top, bottom, and binding side of all pages submitted.

d.

Printing (1) Composition:

Text pages should be single spaced.

(2) Type face and style:

Should be suitable for microfilming or image-copying equipment.

(3) Reproduction:

May be mechanically or photographically reproduced.

All pages of text should be printed on both sides with image printed head to head.

e.

Binding.

Pages should be punched for standard 3-hole loose-leaf binders.

f.

Page numbering.

Pages should be numbered with the two digits corresponding to the chapter and first-level section numbers followed by a hyphen and a sequentiaf number within the section, i.e., the third page in Section 5.2 of Chapter 5 should be numbered 5.2-3.

Do not number the entire report sequentially.

(Note that because of the small number of pages in many sections, this Standard Format is numbered sequentially within each chapter.)

6.

Procedures for Updating or Resising Pages Data and text should be updated or revised by replacing pages.

" Pen and ink" or " cut and paste" changes should not be used.

xii

The changed or revised portion of each page should be highlighted by a

" change indicator" mark consisting of a bold vertical line drawn in the margin opposite the binding margin.

The line should be of the same length as the portion actually changed.

All pages submitted to update, revise, or add pages to the report should show the date of change and a change or amendment number in the lower righthand corner.

A guide page listing the pages to be inserted and the pages to be removed should accompany the revised pages.

1.

INTRODUCTION AND GENERAL DESCRIPTION OF STORAGE SYSTEM Provide introductory information, preferably in narrative style, on the purpose for and the general description of the storage system.

The information in this chapter should enable the reader to obtain a basic understanding of the storage system and the protection afforded the general public and the operating personnel without having to refer to the subsequent chapters.

Review of the detailed chapters that follow can then be accomplished with better perspective and with recognition of the relative safety importance of each individual item to the overall design, construction, and operation of the spent fuel storage system.

The language in this guide assumes that only one type of cask will be used for storage.

If more than one type of cask is to be used, the design information for each type of cask should be provided in Chapter 3 and analyzed in Chapters 4, 5, 7, 8, and 10.

1.1 Introduction Present briefly the principal features of the storage system.

Include the type of cask to be used; a general description of the storage requirements; the total amount of spent fuel to be stored; the type, form, quantities, and potential sources of the spent fuel to be stored; and estimated schedules for construction and operation of the storage system.

1.2 General Description of Location Include a summary description of the proposed location of the storage sys-tem.

The description should include identification and description of the collocated nuclear reactor, arrangement of major structures and equipment, and general layout of the storage site.

Describe where the storage system will be located with respect to other structures. Any additional features likely to be of special interest because of their relationship to safety should be identified.

1-1

I

1. 3 General Storage System Description A description of the storage cask, arrangement of the casks in storage, and other pertinent information should be presented.

This description should include such things as the loading and unloading systems, the means for onsite transport of the loaded cask, cask storage array, and other storage system facilities.

Provide sufficient detail in the discussion and accompanying charts and tables to provide an understanding of the systems involved.

1.4 Identification of Agents and Contractors Identify the prime agents or contractors for the design, construction, and operation of the storage system, including cask vendors.

All principal consultants and outside service organizations, including those providing quali-ty assurance services and cask manufacturers, should be identified.

The divi-sion of responsibility among the designer, architect engineer, vendor, fabrica-tors, and applicant should be delineated.

l l

1. 5 Material Incorporated by Reference This section should provide a tabulation of safety analysis reports, environmental reports, or topical safety analysis reports (TSARS) that are incorporated by reference as part of the SAR.

In this context, a TSAR is de-fined as a report that has been prepared by architect engineers, vendors, or other organizations and filed with the NRC for approval under the Topical Report Review Program.

For each safety analysis report, environmental report, or TSAR, this tabulation should include the title, the report number, the date submitted to the NRC, and the sections in which this report is referenced.

Sections of the TSAR that have been withheld from public disclosure pursuant to S 2.790(b) of 10 CFR Part 2 as proprietary documents should also be referenced.

This sec-tion should include a tabulation of any documents submitted to the NRC in other applications that are incorporated in whole or in part in this application by reference (e.g., SAR for a reactor license).

If any information submitted in connection with other applications is incorporated by reference in this SAR, summaries or explanations of such information should be included in appropriate sections.

1-2

2.

SITE CHARACTERISTICS Provide information on the location of the storage casks and a brief description of the geographical, demographical, meteorological, hydrological, seismological, and geological characteristics of the storage site and surround-ing vicinity.

The objective is to identify site characteristics that are important for the design of the spent fuel storage system.

Since the storage system will be located at the site of a licensed reactor, much of the required siting information should be available in previous sub-mittals to the NRC.

Any material in this chapter that is covered in the environmental report (ER) or safety analysis report (SAR) for the collocated reactors may be covered by clear and specific reference to the subject matter in the ER or SAR.

It is important that the :pplicant confer with the NRC staff prior to preparing the SAR to determine the applicability of such information.

2.1 Geography and Demography of Site Selected 2.1.1 Site Location The location of the site for the placement of the storage system should be described in relationship to other onsite b'uildings.

The State and county in which the storage system is to be located should be identified, as well as the location of the storage system relative to prominent natural and man-made features such as rivers, lakes, and the local road network.

Additional maps should be provided to present detail near the spent fuel storage site to estab-lish orientation of proposed or existing buildings, roads, railroads, streams, ponds, and transmission lines.

This section may be referenced in subsequent chapters to minimize repetition.

2.1.2 Site Description A map of the storage system site should be included and should be of suitable scale to clearly define the boundary of the site and the distance 2-1

from significant features of the storage system to the site boundary.

The area to be considered as the controlled area should be clearly delineated if its boundaries are not the same as those of the existing facilities.

The dis-tance from the proposed storage location to the controlled area boundary should be clearly presented.

The applicant should include a description of legal responsibilities with respect to the properties described for the proposed location of the storage casks.

The topography of the site and vicinity should be descrit d by suitable contour maps that indicate the character of surface drainage patterns.

Vegetative cover and surface soil characteristics should be described suffi-ciently to indicate potential erosion and fire hazards.

For any activity conducted within the area controlled by the applicant but not related to the operation of the storage system, identify the activities involved, the boundaries within which the applicant will control such activi-ties, and any potential interaction of such activities and the operation of the I

storage system.

2.1.3 Population Distribution and Trends Population information based on the most recent census data should be presented to show the population distribution as a function of distance and direction from the storage site.

Projected future population changes should be specified through the proposed life of the storage system.

2.1. 4 Uses of Nearby Land and Waters Uses of nearby land and waters within a minimum of an 8-kilometer (5-mi) radius should be described. A brief description of farming, dairy, industrial, residential, and recreational activities should be presented.

2-2

2.2 Neatby Industrial, Transportation, and Military Facilities l

Identify nearby industrial, transportation, and military installations that are within 8 kilometers (5 mi) of the storage site. As appropriate for each, provide a description of products or materials produced, stored, or transported and the maximum quantities for each with emphasis on those items that could present a hazard to the safe operation of the storage system.

Summarize items that may present a hazard to the storage site from nearby activities. The following are typical considerations to be evaluated:

1.

The effects of explosion of chemicals, flammable gases, or munitions; 2.

The effects of explosions of large natural gas pipelines that pass close to the storage site; 3.

The effects of detonation of the maximum amount of explosives permitted to be stored at mines or stone quarries near the site; 4.

The effects of

{

a.

Brush or forest fires, b.

Fires from transportation accidents, and c.

Fires from adjacent industries; and 5.

The effects of aircraft impacts on the storage casks, taking into account aircraft size, velocity, weight, and fuel loading for storage sites in the vicinity of airports.

If tall structures such as discharge stacks are located near the proposed f

storage site, evaluate the potential for damage to the storage casks in the event that these structures collapse.

2.3 Meteorology This section should provide a brief meteorological description of the storage site and its surrounding area. Meteorological conditions for the storage site should be the same as for the collocated nuclear power plant.

l Meteorological cor.ditions that influence the design and operation of the storage site shculd be identified.

2-3

2.3.1 Regional Climatology Describe the climate of the region, pointing out characteristics attribu-table to the terrain.

Indicate annual extremes and seasonal weather conditions, including temperature, precipitation, relative humidity, and prevalent wind direction.

Provide summary data on 1.

The frequency and duration of maximum and minimum temperatures; 2.

The frequency and duration of heavy rain, snow, and ice storms; 3.

The frequency and intensity of thunderstorms and lightning strikes; 4.

The frequency and intensity of strong winds, tropical storms, tornadoes; and 5.

The frequency and intensity of other meteorological conditions (e.g., blowing dust) that could affect the passive cooling system of the cask.

These data should be reported in sufficient detail to indicate impacts on the cask and storage site design and operation.

All information should be fully documented and the historical record on which the information was based should be identified.

Sources of such information could include the National Climatic Center, National Weather Service stations, collocated nuclear facili-ties, government facilities (e.g., military installations), and private organizations such as universities that have maintained quality-controlled data collection programs.

The validity of the information provided, with respect to representation of conditions at or near the site, may be substanti-ated by appropriate references.

2.3.2 Local Meteorology 2.3.2.1 Data Sources.

Provide onsite data summaries and nearby weather summaries, identifying the methods and frequencies of collection and pointing out the data collection undertaken specifically for this SAR.

Data may be obtained from the onsite meteorological measurements program of the collocated nuclear power plant.

Provide joint frequency distributions of wind speeds, wind direction, and atmospheric stability.

l 2-4

l 1.

INTRODUCTION AND GENERAL DESCRIPTION OF STORAGE SYSTEM Provide introductory information, preferably in narrative style, on the purpose for and the general description of the storage system.

The information in this chapter should enable the reader to obtain a basic understanding of the storage system and the protection afforded the general public and the operating personnel without having to refer to the subsequent chapters.

Review of the detailed chapters that follow can then be accomplished with better perspective and with recognition of the relative safety importance of each individual item to the overall design, construction, and operation of the spent fuel storage system. The language in this guide assumes that only one type of cask will be used for storage.

If more than one type of cask is to be used, the design information for each type of cask should be provided in Chapter 3 and analyzed in Chapters 4, 5, 7, 8, and 10.

1.1 Introduction Present briefly the principal features of the storage system.

Include the type of cask to be used; a general description of the storage requirements; the total amount of spent fuel to be stored; the type, form, quantities, and potential sources of the spent fuel to be stored; and estimated schedules for construction and operation of the storage system.

j 1.2 General Description of Location Include a summary description of the proposed location of the storage sys-tem.

The description should include identification and description of the collocated nuclear reactor, arrangement of major structures and equipment, and general layout of the storage site.

Describe where the storage system will be located with respect to other structures.

Any additional features likely to be of special interest because of their relationship to safety should be identified.

1-1

l. 3 General Storage System Description dIEhk W

A description of the storage cask, arrangement of the casks in storage, and other pertinent information should be presented.

This description should include such things as the loading and unloading systems, the means for onsite transport of the loaded cask, cask storage array, and other storage system facilities.

Provide sufficient detail in the discussion and accompanying charts and tables to provide an understanding of the systems involved.

1.4 Identification of Agents and Contractors Identify the prime agents or contractors for the design, construction, and operation of the storage system, including cask vendors.

All principal consultants and outside service organizations, including those providing quali-ty assurance services and cask manufacturers, should be identified.

The divi-sion of responsibility among the designer, architect-engineer, vendor, fabrica-tors, and applicant should be delineated.

1. 5 Material Incorporated by Reference

,-r This section should provide a tabulation of safety analysis reports, environmental reports, or topical safety analysis reports (TSARS) that are incorporated by reference as part of the SAR.

In this context, a TSAR is de-l fined as a report that has been prepared by architect engineers, vendors, or other organizations and filed with the NRC for approval under the Topical Report Review Program.

For each safety analysis report, environmental report, or TSAR, this tabulation should include the title, the report number, the date submitted to the NRC, and the sections in which this report is referenced.

Sections of the TSAR that have been withheld from public disclosure pursuant to S 2.790(b) of 10 CFR Part 2 as proprietary documents should also be referenced.

This sec-tion should include a tabulation of any documents submitted to the NRC in other applications that are incorporated in whole or in part in this application by reference (e.g., SAR for a reactor license).

If any information submitted in ennnection with other applications is incorporated by reference in this SAR, summaries or explanations of such information should be included in appropriate II' sections.

1-2

s 2.

SITE CHARACTERISTICS l

l Provide information on the location of the storage casks and a brief description of the geographical, demographical, meteorological, hydrological, seismological, and geological characteristics of the storage site and surround-ing vicinity.

The objective is to identify site characteristics that are important for the design of the spent fuel storage system.

Since the storage system will be located at the site of a licensed reactor, much of the required siting information should be available in previous sub-mittals to the NRC.

Any material in this chapter that is covered in the environmental report (ER) or safety analysis report (SAR) for the collocated reactors may be covered by clear and specific reference to the subject matter in the ER or SAR.

It is important that the applicant confer with the NRC staff prior to preparing the SAR to determine the applicability of such information.

p 2.1 Geography and Demography of Site Selected 2.1.1 Site Location The location of the site for the placement of the storage system should be described in relationship to other onsite b'uildings.

The State and county in which the storage system is to be located should be identified, as well as the location of the storage system relative to prominent natural and man-made features such as rivers, lakes, and the local road network.

Additional maps should be provided to present detail near the spent fuel storage site to estab-lish orientation of proposed or existing buildings, roads, railroads, streams, ponds, and transmission lines.

This section may be referenced in subsequent chapters to minimize repetition.

2.1.2 Site Description A map of the storage system site should be included and should be of suitable scale to clearly define the boundary of the site and the distance 2-1 l

l t

from significant features of the storage system to the site boundary.

The area to be considered as the controlled area should be clearly delineated if its boundaries are not the same as those of the existing facilities.

The dis-tance from the proposed storage location to the controlled area boundary should be clearly presented.

The applicant should include a description of legal responsibilities with respect to the properties described for the proposed location of the storage casks.

The topography of the site and vicinity should be described by suitable contour maps that indicate the character of surface drainage patterns.

Vegetative cover and surface soil characteristics should be described suffi-ciently to indicate potential erosion and fire hazards.

For any activity conducted within the area controlled by the applicant but not related to the operation of the storage system, identify the activities involved, the boundaries within which the applicant will control such activi-ties, and any potential interaction of such activities and the operation of the storage system.

2.1. 3 Population Distribution and Trends Population inform,' ion based on the most recent census data should be presented to show the popu.' tion distribution as a function of distance and direction from the storage sit'.

Projected future population changes should be specified through the proposed life of the storage system.

2.1.4 Uses of Nearby Land and Waters Uses of nearby land and waters within a minimum of an 8-kilometer (5-mi) radius should be described.

A brief description of farming, dairy, industrial, residential, and recreational activities should be presented.

2-2

2.2 Nearby Industrial, Transportation, and Military Facilities l

Identify nearby industrial, transportation, and military installations I

that are within 8 kilometers (5 mi) of the storage site.

As appropriate for each, provide a description of products or materials produced, stored, or transported and the maximum quantities for each with emphasis on those items that could present a hazard to the safe operation of the storage system.

Summarize items that may present a hazard to the storage site from nearby activities.

The following are typical considerations to be evaluated:

1.

The effects of explosion of chemicals, flammable gases, or munitions; 2.

The effects of explosions of large natural gas pipelines that pass close to the storage site; 3.

The effects of detonation of the maximum amount of explosives permitted to be stored at mines or stone quarries near the site; 4.

The effects of a.

Brush or forest fires, b.

Fires from transportation accidents, and c.

Fires from adjacent industries; and 5.

The effects of aircraft impacts on the storage casks, taking into account aircraft size, velocity, weight, and fuel loading for storage sites in the vicinity of airports.

If tall structures such as discharge stacks are located near the proposed I

storage site, evaluate the potential for damage to the storage casks in the ever* tnat these structures collapse.

2.3 Meteorology This section should provide a brief meteorological description of the storage site and its surrounding area.

Meteorological conditions for the storage site should be the same as for the collocated nuclear power plant.

Meteorological conditions that influence the design and operation of the storage site should be identified.

2-3

2.3.1 Regional Climatology Describe the climate of the region, pointing out characteristics attribu-table to the terrain.

Indicate annual extremes and seasonal weather conditions, including temperature, precipitation, relative humidity, and prevalent wind direction.

Provide summary data on 1.

The frequency and duration of maximum and minimum temperatures; 2.

The frequency and duration of heavy rain, snow, and ice storms; 3.

The frequency and intensity of thunderstorms and lightning strikes; 4.

The frequency and intensity of strong winds, tropical storms, tornadoes; and 5.

The frequency and intensity of other meteorological conditions (e.g., blowing dust) that could affect the passive cooling system of the cask.

These data should be reported in sufficient detail to indicate impacts on the cask and storage site design and operation.

All information should be fully documented and the historical record on which the information was based should be identified.

Sources of such information could include the National Climatic Center, National Weather Service stations, collocated nuclear facili-ties, guvernment facilities (e.g., military installations), and private organizations such as universities that have maintained quality-controlled data collection programs.

The validity of the information provided, with respect to representation of conditions at or near the site, may be substanti-atea by appropriate references.

2.3.2 Local Meteorology 2.3.2.1 Data Sources.

Provide onsite data summaries and nearby mather summaries, identifying the methods and frequencies of collection and pointing out the data collection undertaken specifically for this SAR.

Data may be obtained from the onsite meteorological measurements program of the collocated nuclear power plant.

Provide joint frequency distributions of wind speeds, wind direction, and atmospheric stability.

2-4

l 2.3.2.2 Topography.

Provide a map showing the detailed topographic features (as modified by the placement of the storage site) within an 8-kilo-meter (5-mi) radius of the storage site.

2.3.3 Onsite Meteorolcjical Measurement Program Describe the program being conducted to develop local data and the programs to be used during operations to estimate offsite concentrations of airborne effluents.

The information should include measurements made, loca-tions and elevations of measurements, descriptions of the instruments used, instrument performance specifications, calibration and maintenance procedures, and data analysis procedures.

2.3.4 Diffusion Estimates 2.3.4.1 Basis.

Provide estimates of atmospheric dif fusion at the con-trolled area boundary for appropriate time periods for routine releases and after an accident.

Consideration of any influence that local topography may have should be included.

Show the decrease in relative concentration as a function of dictance.

2.3.4.2 Calculations.

Describe the diffusion equations and the parameters used in the diffusion estimates.

2.4 Hydrology The SAR should contain a discussion of surface and subsurface hydrology related to cask design bases and cask performance criteria.

The discussion should relate this information to cask handling, storage, and the storage system operating sequence and should characterize site hydrologic features, e.g., rivers, streams, lakes, dams, aquifers, ground water and its use.

Topo-graphic maps should be provided as necessary for clarity.

Documents submitted for the collocated reactor may be referenced.

2-5 t

2.5 Geology and Seismology The geologic and seismic characteristics of the area and the storage site, the nature of the investigations performed, results of investigations, conclu-sions, and identification of information sources should be provided.

Supplement the written description with tables and legible graphics, as appropriate.

The information required to satisfy this section is contained in the SAR for the collecated nuclear power plant.

The appropriate sections should be reviewed, updated if necessary, and referenced.

A brief summary of conclusions should be provided in this SAR.

2.5.1 Basic Geologic and Seismic Information The basic geologic and seismic information for the storage site should be presented.

Information from professional papers, dissertations, maps, published reports, the SAR for the collocated nuclear power plant, private communications, or other sources should be referenced.

Material in this section may be included, as appropriate, in Section 2.5.3 and cross-referenced.

The following information should be included in this section:

1.

Storage site geomorphology; 2.

Geologic history of the storage site and surrounding region; 3.

Specific structural features of significance to the storage site; 4.

Large-scale geologic map; 5.

Plot plan showing cask storage locations and all borings, trenches, and excavations; 6.

Geologic profiles showing relationship of storage cask foundations to subsurface materials, including ground water; 7.

Plan and profile drawings showing the extent of excavations and backfill planned at the storage site; 8.

Local geological features that could affect the storage cask place-ment such as zones of alteration, deformation zones, previous earthquakes, zones of structural weakness, and unstable rock formations; 2-6

9.

Site ground-water conditions; 10.

Geophysical surveys to evaluate the stratigraphic structure and bedrock; 11.

Static and dynamic engineering soil and rock properties of materials underlying the storage site; and 12.

Analysis techniques used and the factors of safety for foundation materials.

2.5.2 Vibratory Ground Motion Information should be presented to describe how the data were selected for determining the design basis for vibratory ground motion.

Specific infor-mation and determinations should be included to the extent necessary to clearly establish the design basis for vibratory ground motion.

Information presented in other sections of this SAR may be cross-referenced and need not be repeated.

The following information should be included in the discussion:

1.

Engineering properties of materials for seismic wave propagation and soil-structure interaction analyses, 2.

Earthquake history, 3.

Earthquake probabilities, and 4.

Procedures to determine the design earthquake.

2.5.3 Surface Faulting Information that describes surface faulting at the site should be presented if the method or approach of 10 CFR Part 100, " Reactor Site Criteria," is used.

A summary of the following specific information and determinations should also be included.

Since most of this information is included in the SAR for the col-located nuclear power plant, the information should be reviewed, updated if necessary, and referenced.

1.

Evidence of fault offset, and 2.

Identification of capable faults.

2-7

2.5.4 Stability of Subsurface Materials Information should be presented concerning the stability of rock and soil underneath the storage structure foundations during the vibratory motion asso-ciated with earthquake design.

Evaluate the following types of information to determine if the storage geologic features could affect the storage cask loca-tion foundations:

1.

Geologic features, 2.

Properties of underlying materials, 3.

Plot plan, 4.

Soil and rock characteristics, 5.

Excavations and backfill, 6.

Ground water conditions, 7.

Response of soil and rock to dynamic loading, 8.

Liquefication potential, 9.

Earthquake design basis, 10.

Static analyses, l

11.

Techniques to improve subsurface conditions, and 12.

Criteria and design methods.

l 2.5.5 Slope Stability Information and appropriate substantiation should be presented concerning the stability of all slopes, both natural and man-made (both cut and fill),

the failure of which could adversely affect the storage site.

The information should include a description of slope characteristics, analyses used to deter-mine slope stability, logs of core borings, and compaction specifications.

l e

2-8 l

3.

PRINCIPAL CASK DESIGN CRITERIA Principal design criteria for the type of cask or casks selected by the applicant should be established in this chapter.

The guide language is based on selection of one type of cask.

In the case in which an applicant selects more than one type of cask, each type should be analyzed in each of the follow-ing sections.

In many cases, the cask selected for spent fuel storage will have been analyzed in a topical safety analysis report (TSAR) submitted by the cask vendor.

Clear and specific reference to an NRC-approved TSAR in the appropriate sections may facilitate preparation of this safety analysis report (SAR).

l 3.1 Purposes of Cask Describe the cask, its functions, storage capacity, and the types of fuel to be stored.

3.1.1 Spent Fuel To Be Stored A detailed description of the physical, thermal, and radiological charac-teristics of the spent fuel that will be stored in the cask should be provided.

Compare these characteristics to the design criteria for the cask.

Include spent fuel characteristics such as specific power, burnup, decay time, and heat generation rates.

I 3.1.2 General Operating Functions i

Provide information related to the overall functioning of the cask in the storage system operation.

Information should include onsite handling, trans-port, and utility services required for system operation.

3.2 Desian Criteria for Environmental Conditions and Natural phenomena Identify and quantify the bases for the cask design criteria.

The design criteria for the cask components that are identified as important to safety 3-1

should be emphasized.

Design bases should include such things as meteorology, flooding, seismic activity, ambient temperature range, and peak solar insola-tion.

Clear and specific reference to the appropriate section in an approved TSAR may be adequate.

3.2.1 Tornado and Wind Loadings 3.2.1.1 Applicable Design Parameters.

The design parameters applicable to the design tornado such as translational velocity, rotational velocity, and the design pressure differential and its associated time interval should be specified.

Regulatory Guide 1.76, " Design Basis Tornado for Nuclear Power Plants," contains guidance that may be helpful.

3.2.1.2 Determination of Forces on Structures.

Describe the methods used to convert the tornado and wind loadings into forces on the cask, including the distribution across the cask and the combination of applied loads.

If factored loads are used, the basis for selection of the load factor used for tornado loading should be furnished.

{

3.2.1.3 Tornado Missiles.

The dimensions, mass, energy, velocity, and other parameters snould be selected for a potential tornado-driven missile.* An analysis should be presented to show the potential effect of such a missile on structures, systems, and components important to safety.

3.2.2 Water Level (Flood) Design If the cask is not to be located on a floodfree site, discuss the design loads from forces developed by the probable maximum flood (PMF), including water h:ight and dynamic phenomena such as velocity.

  • Section 3.5.1.4 (paragraph 4 of Section III) of NUREG-0800, " Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants," U.S.

Nuclear Regulatory Commission, Office of Nuclear Reactor Regulation, contains information that may be helpful in developing these data.

A copy of Sec-tion 3.5.1.4 is available for inspection and copying for a fee at the NRl Public Document Room, 1717 H Street, NW., Washington, DC, under Task CE 301-4.

3-2

3.2.3 Seismi Design The design criteria and parameters to be used in the seismic analysis of the cask and cask storage pads should be presented in this section.

If the cask is located on a soil-supported structure (e.g., storage pad), include the depth of the soil over bedrock. This section should also discuss the seismic analysis method and the method used to determine overturning moment for the cask. Clear and. specific reference to appropriate sections of a cask TSAR or the reactor SAR may be adequate.

3.2.4 Snow and Ice Loadings Describe design and operating load criteria used to ensure that maximum snow and ice loads can be accommodated by the cask.

Include an analysis to show that thermal and stress transients will not adversely affect the cask.

3.2.5 Combined Load Criteria Describe, for combined loads, the criteria selected to provide mechanical and structural integrity.

The loads and loading combinations to which the cask is subjected, including the load factors selected for each load component where a factored load approach is used, should be defined.

The design approach used with the loading combination and any load factors should be specified.

Describe the loads acting on the cask such as dead loads, live loads, and earth pressure loads, as well as the design basis accident loads and loads resulting from natural phenomena such as earthquakes, floods, tornadoes, tornado missiles, hurricanes, and snow and ice effects.

The design loading combinations used to examine the effects on localized areas such as penetrations, structural discon-tinuities, prestressing tendon anchor zones, and local areas of high thermal gradients should be provided together with time-dependent loading such as the thermal effects, effects of creep and shrinkage, and other related effects.

Explanation should be provided of the use of an ultimate strength approach with a load factor of 1.0.

3-3

3.3 Safety Protection Systems 3.3.1 General Identify special considerations in design because of site selection, cask operating conditions, or other requirements since the long-term safety and secure confinement of the stored fuel must be ensured.

3.3.2 Protection by Multiple Confinement Barriers and Systems 3.3.2.1 Confinement Barriers and Systems.

Discuss each method of confine-ment that will be used to ensure that there will be no uncontrolled release of radioactivity to the environment.

Where the release limits selected are consistent with present practice, a referenced staterr.ent to that effect will suffice; where the limits extend beyond present practice, an evaluation and an explanation based on developmental work and analysis should be provided.

Those criteria may be expressed as explicit l

numbers or as general conditiors.

3.3.2.2 Cask Cooling.

Describe the criteria selected for providing suit-able cooling of the cask by showing capacity standards for normal and off-normal conditions.

3.3.3 Protection by Equipment and Instrumentation Selection 3.3.3.1 Equipment.

Itemize design criteria for key cask equipment items that have been specifically selected to provide protection.

3.3.3.2 Instrumentation.

Discuss the design criteria for instrumentation selected with particular emphasis on features to provide testability and maintenance.

e 3-4

3.3.4 Nuclear Criticality Safety Supply pertinent criteria relating to the appropriate safety margins provided to ensure that a subcritical situation exists under credible handling and storage conditions.

3.3.4.1 Control Methods for Prevention of Criticality.

Present the methods to be used to ensure that subcritical situations are maintained in storage under the worst credible conditions.

3.3.4.2 Error Contingency Criteria.

To support the above information, define the error contingency criteria selected.

3.3.4.3 Verification Analyses.

Present the criteria for establishing and verifying models and computer programs used in analyses.

ANSI /ANS-8.1-1983,

" Nuclear Criticality Safety in Operations with Fissionable Materials Outside Reactors,"* provides information concerning validation of criticality calculations.

I 3.3.5 Radiological Protection A portion of the radiological protection design criteria was discussed in Section 3.3.2.

Present any additional radiological protection design criteria.

Provide an estimate of collective doses (in man-rem) per year, including the collective doses associated with cask operation, maintenance, repair, and decommissioning. When special provisions such as time and distance are to be included, determine the design dose rate in occupancy areas.

Show that further reduction of cellective doses is not practicable.

  • Copies may be obtained from the American Nuclear Society, 555 North Kensington Avenue, La Grange Park, Illinois 60525.

I 3-5

3.3.6 Fire and Explosion Protection Provide the design criteria selected to ensure that all safety functions will successfully withstand credible fire and explosion conditions.

3.3.7 Materials Handling and Storage Describe the design criteria for spent fuel storage.

Specifically cover cooling requirements, criticality, and contamination control.

Discuss criteria for rietecting and handling damaged fuel elements.

3.4 Summary of Storage Cask Design Criteria Provide a summary of the design crit.eria used during the design of the storage cask.

This summary should identify an envelope of criteria and may be presented in tabular form.

l I

3-6

4.

STORAGE SYSTEM Provide descriptive information on the various components of the storage system and their locations on the site.

Use drawings and maps as appropriate.

Describe and evaluate each part of the storage system with emphasis on those features that are important to safety.

Show that storage casks that are being considered can be handled, loaded, stored, and unloaded either under the exist-ing reactor operating license or by facilities to be included under the Part 72 license.

Describe and evaluate special design features employed to withstand environmental and accident forces.

Relate the design bases and use of indus-trial codes to the design criteria presented in Chapter 3, " Principal Cask De-sign Criteria."

Identify structures, systems, and components that are covered by the quality assurance program.

4.1 Location and Layout I

Identify the location of the cask storage site, the collocated nuclear power plant spent fuel pool, and the interconnecting transportation route for the spent fuel storage casks on a map or drawing to scale.

Also include other onsite facilities, roadways, railroad lines, and utility and water service locations.

4.2 Storage Site Provide the design bases for the storage site including (1) the analysis and design procedures for tornado, earthquake, fire, and explosion effects, (2) the general analysis and design procedures for normal, off-normal, and special load-ings and load combinations, and (3) allowable foundation loads and deflections and deformation stresses for storage pads and structures.

4.2.1 Structures specifications of supporting Describe the design bases and engineerin u I

storage structures.

This description should include cask storage pads.

Discuss 4-1

applicable nationally recognized codes and standards, the materials of construc-tion, and the fabrication and inspection to be used.

4.2.2 Storage Site Layout Provide engineering drawings, plans, and elevations showing the layout of the functional features of the storage site.

Include spatial and equipment identification data directly on the layouts with suitable designations in tabu-lar listings.

Provide engineering drawings, plans, and elevations showing the total array of the storage casks.

Include sectional drawings as required to relate all features of the storage site.

4.2.3 Storage Cask Description Provide a summary description of the cask or types of cask that will be used.

If a specific storage cask has been identified, a reference to the approved topical safety analysis report (TSARi sill suffice with a brief discussion of the results of the TSAR review.

If a TSAR has not been submitted

{

for review or if the storage cask has not been identified, a more detailed description and evaluation of the cask should be provided.

4.2.3.1 Function.

Describe the function of the storage cask, and discuss the performance objectives.

4.2.3.2 Description.

Using equipment sketches and engineering drawings, identify the various components of the cask.

Include a discussion of the fea-tures used to ensure that operating personnel are protected from radiation and that criticality will not occur.

Describe the internal components of the cask such as the basket assembly.

Provide design provisions for interfaces with other equipment.

This information may be included in a TSAR for a particular cask and may be referenced.

l 4.2.3.3 Design Bases and Safety Assurance.

Present the design codes used and specifications necessary to show that a sufficient margin of safety exists under normal and accident conditions.

Include detailed analyses showing that the design criteria as defined in Chapter 3, " Principal Cask Design Criteria,"

are fulfilled.

4-2

d 4.2.4 Instrumentation System Description Identify those aspects of the storage system relied on to ensure that ade-quate reliability is provided and that provisions have been included in the design for safe storage conditions or curtailment of storage system operations in the event of off-normal and accident conditions.

Relate these to the design criteria presented in Chapter 3, " Principal Cask Design Criteria." Describe the various monitoring systems that provide indications of off-r.ormal operations.

By means of instrumentation flowsheets, d(scuss the instrumentation and control features associated with the storage system.

Discuss how instrumentation systems will monitor variables and systems important to safety over anticipated ranges for normal operation, off-normal operation, and accident conditions.

Describe redundancy of safety features that may be necessary to ensure adequate safety of spent fuel storage.

The variables and systems that may need surveillance and control include (1) confinement leakage indications, (2) cask liquid levels, (3) cask pressures, I

(4) fuel temperature, and (5) area radiation and airborne radioactivity levels.

Discuss the provisions for testability of the instrumentation and main-tenance of radiation control systems.

Describe how the instrumentation and radiation control systems are designed to fail-safe or to indicate faulty condi-tions such as disconnection, loss of energy or motive power, or adverse environ-mental conditigns.

4.3 Transport System A transport system will be needed to move the loaded casks from the nuclear power plant's spent fuel pool or other loading facilities to the storage site.

This movement should be totally conducted on site to allow the transport system to be licensed under 10 CFR Part 72 and avoid licensing related to 10 CFR Part 71.

The transport system should include a transport vehicle (e.g., truck and lowboy trailer), means for loading and unloading at both the spent fuel pool and at the storage site, and a transfer path between the two areas.

I 4-3

4.3.1 Function Describe the function of the transport system and of the components.

Provide a narrative description of how the system will operate.

Discuss the performance objectives.

4.3.2 Components Describe the transport system components in detail.

Use individual equip-ment sketches, engineering drawings, and plans.

Where applicable, identify nationally recognized codes and standards, and itemize in tabular form features that will be covered by the quality assurance program discussed in Chapter ll,

" Quality Assurance."

For the transfer path, indicate on a site map the location of the path.

Describe the construction of the pathway.

Indicate any additional uses for the path that are not related to the movement of spent fuel storage casks.

l 4.3.3 Design Bases and Safety Assurance Present the design bases and codes used and specifications necessary to show that a sufficient margin of safety is provided under normal, off-normal, and accident conditions.

Backup provisions and interfaces with the collocated reactor spent fuel pool and the storage site should be included.

Include a discussion of the features used to ensure that operating personnel are ade-quately protected frcm radiation.

4.4 Operating Systems This section should include an analysis of the spent fuel storage and related system operations.

Some of these systems may be part of the collocated nuclear power plant but may also be used during storage of spent fuel.

Systems that should be included are the cask loading and unloading system, cask decon-tamination system, cask repair and maintenance system, cask transport system, and cask storage system.

Some of the information requested in this section such as information or technical specifications related to heavy loads and 4-4

crane capacity may be included in the SAR or other documents related to the collocated reactor operating license.

Include references to the SAR of a collocated reactor, technical specifications, and the storage cask TSAR for support.

4.4.1 Loading and Unloading System The system that will be used to load the fuel into the storage cask, seal the cask, and prepare the cask for transport to the storage site should be described.

This section should also include a description of the procedures and equipment used to unload the cask.

4.4.1.1 Function.

Describe the function of the loading and unloading system, and discuss the performance objectives of the system.

4.4.1.2 Major Components and Operating Characteristics.

Describe the design and operating features of the system.

Use individual equipment sketches, engineering drawings, layouts of equipment location, and limits imposed on the design to achieve safety.

Identify which components are shared with the nuclear power plant operations.

Describe the equipment that will be used to prepare the cask for loading or unloading operations such as cask evacuation and backfill, cask cooldown, and crud control during unloading.

4.4.1.3 Safety Considerations and Controls.

The design features that ensure safe handling of the spent fuel should be described.

Present the design bases, codes, and specifications that ensure a sufficient margin of safety under normal, off-normal, and accident conditions.

Provide details on backup provisions and interfaces with other systems or components.

Discuss specific components that are required to be operable during loading and unloading opera-tions to ensure that exposures to operating personnel are reduced to as low as is reasonably achievable (e.g., for control of crud and other radioactive material).

4.4.2 Decontamination System This system may be used to decontaminate the cask after it has been loaded j

and removed from the nuclear power plant's spent fuel pool.

4-5

4.4.2.1 Function.

Describe the function of the decontamination system for equipment and personnel.

Discuss the operating features of the system and the decontamination techniques that may be used for decontamination and the limitations of each technique.

4.4.2.2 Major Components and Operating Characteristics.

Describe the components of the cask decontamination system and how this system interacts with other service and utility systems.

Discuss the operating capabilities of the system.

4.4.3 Storage Cask Repair and Maintenance Indicate the location of the storage cask repair and maintenance area.

Provide an engineering drawing of the shop layout with major items of equipment identified.

Describe modes of operation with emphasis on contamination control and occupational radiation exposure reduction.

4.4.4 Utility Supplies and Systems l

Identify the utility services needed for operation of the storage system (e.g., air, water, electricity).

The utility supply and distribution systems should be described and shown on drawings and plans.

4.4.5 Other Systems Identify other systems that may be used in support of the storage system.

Continue additional systems sequentially (e.g., 4.4.4.1, 4.4.4.2,

..).

For each system, provide the following information:

1.

Functional Description.

Describe the portion of the syst?m to be used, its function, and how the function will be accomplished.

2.

Major Components.

If more than one component is included in a parti-cular system, explain the interrelationship of the individual components and the means by which these are combined within the system.

l 4-6

3.

Design Description.

Discuss the design, design capacity (including materials of construction where appropriate), op'erating limits, and standards and codes used.

Describe the layout of equipment from the standpoint of mini-mizing personnel exposures to radiation during operations and maintenance.

4.

Safety Criteria and Assurance.

From the parameters discussed in the preceding sections, summarize the means used for ensuring the system is operated and maintained safely.

4.5 Classification of Structures, Systems, and Components Provide a classification of the structures, systems, and components selected in the design according to their importance to the safety function they perforfa, the seismic design considerations, and the relationship of the quality require-ments of an item with respect to its function and performance.

Describe the criteria for selecting these categories.

Structures, systems, and components that might be included in this classification system are the storage cask and monitoring systems.

4.6 Decommissioning Plan Submit a proposed decommissioning plan that includes information on proposed practices and methods for decontamination of the facility and site, disposal of residual radioactive material after the spent fuel has been removed, and financial arrangements made to provide reasonable assurance that decommissioning will be carried out in a timely manner.

A description of design and operational features that may facilitate decommissioning should be included.

4-7

l 5.

STORAGE SYSTEM OPERATIONS In this chapter, provide a detailed description of operations and a general plan for the overall operation of the storage system.

Identify potentially hazardous operations.

Sufficient detail should be provided to indicate how the applicant intends to conduct all operations and still maintain the indepen-dence of the spent fuel storage system.

5.1 Operation Description 5.1.1 Narrative Description Describe the means that will routinely be used during storage to evaluate the condition of the storage cask, e.g., monitoring of external radiation, interior and/or external temperatures, seal leakage, periodic examination for structural deterioration, foundation soundness, and security of contents.

This should also include the means for evaluating the storage cask integrity during storage and prior to movement for unloading.

Describe the operational sequence that will be followed during the unload-ing of a storage cask.

This unloading may occur any time during the storage life and may be caused by a defect, failure of a component (e.g., seals), or some other occurrence.

Include a range of operations that could occur, e.g.,

replacement of a seal or unloading of a storage cask that contains damaged fuel.

The handling of damaged fuel would be considered an off-normal event.

The consequences of this event should be discussed in Chapter 8, " Accident Analyses."

However, the sequence of operations to handle this event should also be dis-cussed in this chapter.

This discussion should include cask sampling and flush-ing and avoiding radioactive material releases, which could cause significant contamination of the unloading area such as the pool.

I 5-1

5.1. 2 Flowsheets In support of the description above, supply flowsheets showing the sequence of operations and their controls.

Provide a description of the operations.

Sufficient details should be given to derive source terms for radiation exposure determinations to be developed in Chapter 7, " Radiation Protection."

Include equipment descriptions with dimensions, design and operating characteristics, materials of construction, special design features, and operating limitations.

5.1.3 Identification of Subjects for Safety Analysis Identify subjects for safety analysis.

Reference to this part of the chapter may be made, as applicable, in subsequent discussions of design and operating features.

5.1.3.1 Criticality Prevention.

Provide a summary description of the principal design features, procedures, and special techniques used to pre-clude criticality in all portions of the storage system.

{

5.1.3.2 Instrumentation.

Provide a summary description of the instruments used to detect off-normal operations.

The description should include test-ability, redundancy, and failure conditions.

5.1.3.3 Maintenance Techniques.

Discuss the rationale and outline the techniques to be used for major maintenance tasks such as those needed for the transport vehicle and the storage cask.

5.2 Control Room and Control Areas Discuss the location of annunciators that indicate off-normal conditions.

Describe how the off-normal condition is interpreted and how the appropriate personnel will be notified.

Describe actions that would be taken to correct the situation.

9 l

5-2

'd 5.3 Analytical Sampling Provisions for obtaining samples for analysis and controls necessary to ensure that operations are within prescribed limits should be discussed.

This may include gas samples from the storage cavity or sealing system.

Describe the facilities and analytical equipment that will be available to perform the analyses.

Discuss the provisions for obtaining samples during off-normal condi-tions to ensure that prescribed limits have not been violated.

Discuss also quality assurance provisions, e.g., maintenance, calibration, testing, that will en. ore proper sampling and analyses.

m

?~./

/* %

m l

l 5-3

/

s 6.

WASTE MANAGEMENT By reference to Chapter 3, " Principal Cask Design Criteria," provide the primary design bases and supporting analyses for demonstrating that radioactive waste materials will be safely confined.

The existing waste handling system at the collocated reactor may be used to handle the storage system radioactive waste.

Reference may be made to this section of the nuclear power plant's SAR for information concerning design, capacity, operating limitations, and procedures.

Classify anticipated radioactive wastes with respect to source, chemical and radiological composition, and method and design for treatment and handling.

Previously submitted flowsheets and diagrams may be cross-referenced.

6-1 a

(\\

1 V

7.

RADIATION PROTECTION This chapter should provide information on methods for radiation protection and on estimated radiation exposures to operating personnel during normal opera-tion and anticipated operational occurrences (including radioactive material handling, packaging, transfer, processing, storage, and disposal; maintenance; routine operational surveillance; and calibration).

This chapter should also provide information on layout and equipment design, the planning and operating programs, and the techniques and practices employed by the applicant in meeting the standards of 10 CFR Part 20 for protection against radiation, including ALARA.

Reference to other chapters of this SAR or to the collocated nuclear power plant's SAR should be made where appropriate.

A description of how the existing ALARA program may be modified and applied to the spent fuel storage system could simplify presentations in this chapter.

\\

O 7.1 Ensuring That Occupational Radiation Exposures Are As Low As Is Reasonably Achievable (ALARA) 7.1.1 Policy Considerations and Organization Describe the management policy and organizational structure related to ensuring that occupational exposures to radiation are ALARA. Describe the activities that will be conducted by the individuals having responsibility f

l for radiation protection.

l 7.1. 2 Design Considerations Describe the storage system layout and equipment design considerations j

that are directed toward ensuring that occupational radiation exposures are ALARA. Describe how the design is directed toward reducing the (1) need for l

maintenance of equipment, (2) radiation levels and time spent where maint-W enance is required, and (3) contamination control in handling, transfer, and storage of radioactive materials.

l 7-1 6-

7.1.3 Operational Considerations Describe the methods and procedures used to ensu,e that occupational radia-tion exposure will be ALARA.

7.2 Radiation Sources 7.2.1 Characterization of Sources The sources of radiation that are the bases for the radiation protection design and the basis for determining their curie values should be described.

For shielding calculations, the description should include a tabulation of all sources by isotopic composition, x-and gamma-ray energy groups from zero to the maximum photon energy and the respective photon yield, and source geometry.

In addition to the spent fuel in storage, the sources should include radioactive materials contained in equipment and storage containers throughout the storage system. This should include items such as crud that may be removed during fuel handling in the spent fuel pool, if pertinent.

Indicate the physical and chemi-l cal forms of these sources.

7.2.2 Airborne Radioactive Material Sources The sources of radioactive material that may become airborne in areas accessible to, or normally occupied by, operating personnel should be described.

This may include operations that occur in the nuclear power plant's spent fuel pool but are associated with the storage system such as loading and unloading of the storage cask.

The description should include a tabulation of the calculated concentrations of airborne radicactive material by nuclides expected during normal and anticipated operational occurrences in areas normally occupied by operating personnel.

This description should include both gaseous and particulate radioactive material.

Provide the models and parameters for calculating airborne concentrations of radioactive materials.

9 7-2

i r

7.3 Radiation Protection Design Features v

7.3.1 Storage System Design Description Describe equipment and system design features used for ensuring that occupational exposures to radiation are ALARA and that a high degree of inte-grity is obtained for the confinement of radioactive materials.

Provide scaled layout and arrangement drawings of the storage system show-ing the locations of all sources described in Section 7.2.

Include specific activity, physical and chemical characteristics, and expected concentrations.

Provide on the layouts the radiation area designations, including area bound-aries and type of interface (e.g., partitions, locked gates, barriers, fences).

The layouts should show shield wall thicknesses, controlled access areas, personnel and equipment decontamination areas, contamination control areas and type of controls, traffic patterns, location of the health physics facilities, l

location of airborne radioactive material monitors and area radiation monitors at the storage site, and location of the counting room.

Provide the design radiation dose rate for each area and activity.

Describe the facilities and equipment involved, including any special equipment provided specifically for radiation protection.

7.3.2 Shielding Provide information on the shielding for the appropriate radiation sources identified in Section 7.2.

Show the design of penetrations, the material of construction, the method by which the shield parameters (e.g., attenuation coef-l ficients, buildup factors) were determined, and the assumptions, codes, and techniques used in the calculations.

Describe special protective features that use shielding, geometric arrangement (including equipment separation), or remote handling to ensure that occupational exposure to radiation will be ALARA in nor-mally occupied areas.

Describe the use of portable shielding, berms, or special buildings at the storage site used for shielding if applicable.

This information may be included in the approved topical report for l

specific cask designs.

If this is the case, reference the appr:pr hte 7-3 L

sections of the topical report for the storage cask shielding description and calculations.

7.3.3 Area Radiation and Airborne Radioactivity Monitoring Instrumentation Describe the fixed area radiation monitors and airborne monitoring instru-mentation and their placement.

Describe the criteria and methods used for determining setpoints for alarms from the radiological monitoring system.

Provide information on any auxiliary and emergency power supplies (if used),

range, sensitivity, accuracy, energy dependence calibration methods and fre-quency, alarm setpoints, recording devices, and location of detectors, read-outs, and alarms for the monitoring instrumentation.

7.4 Estimated Onsite Collective Dose Assessment The estimated annual occupancy for each radiation area within the storage system should be tabulated and the bases for the values provided.

Provide estimates of annual collective doses (in person-rems) for the functions listed l

above and the assumptions used in determining these values.

7.5 Health Physics Program 7.5.1 Organization Describe how the existing health physics organization will be revised to accommodate the storage system.

7.5.2 Equipment, Instrumentation, and Facilities Describe equipment, instrumentation, and other facilities that will be added or revised as a result of the spent fuel storage system.

7.5.3 Procedures Describe how existing health physics procedures will be applied to the l

spent fuel storage system.

7-4 A

t t

[

7.6 Environmental Monitoring Program i

i Changes and additions, if any, to the existing environmental monitoring I

program that may be required as a result of the spent fuel storage system should be described.

i l

t D

l l

l l

I l

7-5 A

/

' 8.

ACCIDENT ANALYSES The evaluation of the safety of the storage system is accomplished in part by analyzing the response of the system to postulated accident events in terms of (1) minimizing the causes of such events, (2) the quantitative identification and mitigation of the consequences, and (3) the ability to cope with each situation if it occurs.

In previous chapters, features important to safety have been identified and discussed.

The purpose of this chapter is to identify and analyze a range of credible accident occurrences (from minor accidents to the design basis acci-dents) and their causes and consequences.

For each situation, reference should be made to the appropriate chapter and section describing the considerations to prevent or mitigate the accident.

ANSI /ANS-57.9-1984, " Design Criteria for an Independent Spent Fuel Storage l

Installation (Dry Storage Type),"* defines four categories of design events that provide a means of establishing design requirements to satisfy operational and safety criteria.

The first design event is associated with normal operation.

The second and third design events apply to events that are expected to occur during the life of the installation.

The fourth design event is concerned with natural phenomena or low probability events.

8.1 Off-Normal Operations In this section, design events of the second type as defined in ANSI /ANS-57.9-1984 should be considered.

They may include malfunctions of systems, minor leakage, limited loss of external power, or operator error.

In general, the consequences of the events discussed in this section would not have a significant effect beyond the controlled area.

The following format should be used to present the desired detail.

l

  • Copies may be obtained from the American Nuclear Society, 555 North Kensington Avenue, La Grange Park, Illinois 60525.

8-1

8.1.1 Event Identify the event, including the location of event, type of failure or misoperation, and system or systems involved.

Those events that are common to the collocated nuclear power plant and have been analyzed in its SAR need only be listed with reference to the appropriate section of the power plant's SAR if the consequences are the same.

8.1.1.1 Postulated Cause of Event.

Describe the sequence of occurrences that could initiate the event under consideration and the bases upon which credi-bility or probability of each occurrence in the sequence is determined.

The following should be provided:

1.

Starting conditions and assumptions; 2.

A step-by-step sequence of the course of each event, identifying all protection systems required to function at each step; and 3.

Identification of any operator actions necessary.

l The discussion should show the extent to which protective systems should function, the effect of failure of protective functions, and the credit taken for operation safety features.

The performance of backup protection systems during the entire course of the event should be analyzed.

The discussion also should include credit taken for the functioning of other systems and consequences of failure.

The analysis given should permit an independent evaluation of the adequacy of the protection system as related to the event under study.

The results can then be used to determine which functions, systems, interlocks, and controls are important to safety and what actions may be required.

8.1.1.2 Detection of Event.

Discuss the means or methods such as visual i

or audible alarms or routine inspections performed on a stated frequency to be provided to detect the event.

Provide for each event an assessment of response time.

8-2

A 8.1.1.3 Analysis of Effects and Consequences.

Analyze the effects and particularly any radiological consequences of trie event.

The analysis should 1.

Show the methods, assumptions, and conditions used in estimating the course of events and the consequences; 2.

Identify the time-dependent characteristics and release rate of radioactive materials within the confinement system that could escape to the environment; and 3.

Describe the margin of protection provided by whatever system is depended on to limit the extent or magnitude of the consequences.

8.1.1.4 Corrective Actions.

For each event, give the corrective actions necessary to return to a normal situation.

8.1.2 Radiological Impact from Off-Normal Operations The capability of the system to operate safely within the range of anticipated operation variations, malfunctions of operating equipment, and Fy operator error should be shown. The information may be presented in tabular form with the situations analyzed listed in one column accompanied by other columns that identify 1.

Estimated doses (in person-rems),

2.

Method or means available for detecting the respective situations, 3.

Causes of the particular situation, l

4.

Corrective actions, and 5.

Effects and consequences.

8.2 Accidents An analysis of potential accidents that could affect structures, systems, and components important to safety should be presented (e.g., storage cask free-fall, fire, accident in transit).

Any incident that could result in a potential radiation dose of 25 mrem or more beyond the controlled area should be considered for analysis.

Such analyses should address situations wherein

^

(

direct radiation or radioactive materials may be released in such quantity as 8-3

to endanger personnel within the controlled area.

Design events of the third and fourth types as defined in ANSI /ANS-57.9-1984 should be considered in this section.

The following format should be used to provide the desired detail.

8.2.1 Accidents Analyzed Identify the accident, the location or portion of the storage system involved, and t'? type of accident.

Discuss each accident sequentially (e.g.,

8.2.2, 8.2.3..).

Accidents that are common to the collocated nuclear power plant and have been analyzed in its SAR need only be listed with reference to the appropriate section of the nuclear power plant's SAR if the consequences are the same.

8.2.1.1 Cause of Accident.

For each accident analyzed, describe and list the sequence of events leading to the initiation of the accident.

Identify, with respect to natural phenomena, human error, equipment malfunction, or equipment failure.

Include an estimate of probability and how this

{

probability estimate was determined.

8.2.1.2 Accident Analysis.

Analyze the effects and particularly any radiological consequences of each accident.

Show the methods, assumptions, and conditions used in estimating the consequences, the recovery from the consequences, and the steps used to mitigate each accident.

Assess the consequences of the accident to persons and property onsite.

Provide the following information:

1.

The mathematical or physical models employed, including a description of any simplification introduced to perform the analyses.

Identify assump-tions used that are known to differ from those used by the NRC staff.

2.

Identification of any digital computer program or analog simulation used in the analysis with principal emphasis on the input data and the extent or range of variables investigated.

This information should include figures showing the analytical models, flow path identification, actual computer 9

8-4

listing, and complete listing of input data.

The detailed description of mathe-matical models and digital computer programs or listings may be included by reference with only summaries provided.

3.

The physical or mathematical models used in the analyses and the bases for their use with specific reference to a.

The distribution and fractions of the radioactive material inventory assumed to be released from the source into offgas systems; b.

The concentrations of airborne radioactive materials in the confinement atmosphere and buildup on filters during the postaccident time intervals analyzed; and c.

The conditions of meteorology, topography, or other circum-stances and combinations of adverse conditions considered in the analyses.

4.

The time-dependent characteristics, activity, and the release rate of transmissible radioactive materials within the confinement system that could escape to the environment via leakages in the confinement boundaries and leak-age through lines that could exhaust to the environment.

5.

The considerations of uncertainties in calculational methods, equip-ment performance, instrumentation response characteristics, or other indeter-minate effects that should be taken into account in evaluating the results.

6.

The conditions and assumptions associated with the events analyzed, including any reference to published data or research and development investi-gations in substantiation of the assumed or calculated conditions.

7.

The extent of system interdependency with the nuclear power plant system (confinement system and other engineered safety features) contributing directly or indirectly to controlling or limiting leakages from the confinement systems or other sources such as the contribution of confinement air systems and air purification and cleanup systems.

8.

The results and consequences derived from each analysis and the margin of protection provided by whatever system is depended on to limit the extent or magnitude of the consequences.

8.2.1.3 Accident Dose Calculations.

For each accident analyzed, provide and discuss the results of conservative calculations of potential integrated whole-body and critical-organ doses to an individual from exposure to radiation 8-5

l as a function of distance and time a'ter the accident.

Present in terms of a 50 year dose commitment.

Discuss the results and consequences derived from the analysis and the margin of protection provided by whatever system is depended on (i.e., remains operative) to limit the extent or magnitude of the consequences.

8.3 Site Characteristics Affecting Safety Analysis Describe in summary form the site characteristics that have a bearing on the safety analysis, and show how these have been considered in developing suitable margins of safety for the spent fuel storage system.

l 9

8-6

N 9.

CONDUCT OF OPERATIONS 1

The plan'for operation of the spent fuel storage system should be described.

Sufficient detail should be provided to indicate how the applicant intends to conduct operations and ensure that a technically competent staff will be maintained to provide continued implementation of administrative and operating procedures and programs.

9.1 Organizational Structure 9.1.1 Corporate Organization Describe the corporate arrangement or organization responsible for the spent fuel storage system operations.

Provide sufficient information to demon-strate the financial capabilities for construction, operation, and decommission-

,s p

j ing of the storage system.

9.1.1.1 Corporate Functions, Responsibilities, and Authorities.

Describe corporate functions, responsibilities, and authorities with respect to engineering and design, construction, quality assurance, testing, operation, and other applicable activities.

9.1.1. 2 Applicant's In-House Organization.

A description should be pro-vided of the applicant's in-house organization established for the design and construction, quality assurance functions, and operations.

9.1.1. 3 Relationships with Contractors and Suppliers.

The working rela-tionships and organizational interfaces between the applicant, the architect-engineer, and other suppliers and contractors should be described.

9.1.1.4 Applicant's Technical Staff.

Describe the duties, responsibili-ties, and authority of the engineering technical staff, and state numbers of m

personnel and their qualifications, educational backgrounds (disciplines), and technical experience.

Indicate the technical support to be provided by outside consultants.

9-1

a If such arrangements are to be used, the specific areas of responsibility and functional working arrangements of these support groups should be provided.

9.1.2 Operating Organization, Management, and Administrative Control System This section should describe the structure, functions, and responsibilities of the spent fuel storage system operating organization.

The following specific information should be included:

9.1.2.1 Onsite Organization.

Provide a description of the organizational arrangement of the facility showing the title of each position, the flow of responsibility as depicted by an organizational chart, and the number of person-nel in each unit.

Describe the organizational arrangement for ensuring safe operation, the mode of operation, and assigned responsibilities.

9.1.2.2 Personnel Functions, Responsibilities, and Authorities.

Describe the functions, responsibilities, and authorities of major personnel positions, including a discussion of specific succession of responsibility 4

for overall operation of the facility and specifically the storage system in i

the event of ebsences, incapacitation, or other emergencies.

9.1.3 Personnel Qualification Requirements Describe the proposed minimum qualification requirements for onsite storage system personnel.

Any changes in required qualifications and the identification and qualifications of staff personnel finally selected should be presented to the NRC as these occur.

The following specific information should be included.

9.1.3.1 Minimum Qualification Requirements.

The minimum qualifications for major operating, technical, and maintenance supervisory personnel should be stated.

9.1.3.2 Qualifications of Personnel.

The qualifications of the persons assigned to the managerial and technical positions described should be presented j

in resums form.

The resumds should identify persons by position title and.

l 9-2

)

as a minimum, should describe the formal education, training, and pertinent experience of the persons.

9.1.4 Liaison with Other Organizations Discuss arrangements made with outside organizations, including those providing expertise on technical issues concerning storage site selection, sys-tem design and construction, equipment selection or development, and safety evaluations for the spent fuel storage system.

Additionally, any arrangements made with other government agencies shou.2 be presented.

The method or system used to monitor the interfaces between each participant should be included.

9.2 Preoperational Testing and Operation Describe the preoperational testing and operating startup plans for the storage system.

The plans should include preoperational testing of casks and the operational sequence involving their use in the storage system, e.g.,

loading, sealing, storage, unloading.

Emphasize those plans demonstrating that I

the layout, equipment, and planned operations meet safety and design criteria discussed in previous chapters.

Test plans should be presented to verify the integrity of the structures and equipment and to substantiate the safety analyses.

Results obtained from carrying out the planned tests should be recorded and reported as a supplement to the SAR.

9.2.1 Administrative Procedures for Conducting Test Program Describe the system used for (1) preparing, reviewing, approving, and executing testing procedures and instructions and (2) evaluating, documenting, and approving the test results, including the organizational responsibilities and personnel qualifications of the applicant and its contractors.

Describe also the administrative procedures (i.e., the system for review and auc.t) for incorporating any needed system modifications or procedure changes, based on the results of the tests (e.g., test procedure inadequacies or test results centrary to expected test results).

I 9-3

9.2.2 Test Program Description Describe the test objectives and the general methods for accomplishing these objectives, the acceptance criteria that will be used to evaluate the test results, and the general prerequisites for performing the tests, includ-ing special conditions to simulate normal and off-normal operating conditions of the tests listed.

9.2.2.1 Physical Facilities.

For the physical facilities, components, and equipment, identify the items to be tested, type of test, response, and validation.

9.2.2.2 Operations.

Identify those operations to be tested, type of test, response, and validation.

9.2.3 Test Discussion For each preoperational test, provide the following information:

{

1.

Describe the purpose of the test; 2.

Outline the requirements, responsibilities, and authority for conducting the test; 3.

Define the response expected in terms of design bases and criteria discussed in previous chapters, and indicate the margin of difference acceptable for safe operation; 4.

Discuss necessary corrective action if the results of the preopera-tional test do not confirm the expected response; and 5.

Discuss the impact on the collocated nuclear power plant of perform-ing the test on the storage system.

9.3 Training Program Describe the proposed training program, including the scope of training in (1) the storage system operations and design, instrumentation and control, methods of dealing with operating malfunctions, decontamination procedures, and emergency procedures, (2) health physics subjects such as nature and 9-t r

,q sources of radiation, methods of controlling contamination, interactions of

~

radiation with matter, biological effects of radiation, use of monitoring equipment, and (3) nuclear criticality control.

Identify personnel classifica-tion with level of instruction.

Changes and additions to the existing training program could simplify presentations in this section.

9.4 Normal Operations 9.4.1 Procedures The applicant should conduct operations that are important to safety in accordance with approved written procedures.

Include a description of the review, change, and appraval practices for storage system operat%g, maintenance, and testing procedures.

9.4.2 Records m

Present the management system for maintaining records relating to the operation of the storage system.

This should include quality assurance records; operating records, including principal maintenance, alterations, or additions made; records of off-normal occurrences and events associated with radioactive releases; and environmental survey records.

9.5 Emergency Planning Describe plans for coping with emergencies.

Reference to the existing collocated nuclear power plant's emergency plan and a statement of how it will be applied in the case of the spent fuel storage system is adequate.

l l

9.6 Physical Security Plan l

A description of and a schedule for proposed changes, related to the spent fuel storage system, to the NRC-approved physical sec.ority plan should be

]

provided.

9-5

,em 10.

OPERATING CONTROLS AND LIMITS The operating controls and limits for the spent fuel storage system are derived from the safety assessment of the storage system and include all important safety, environmental, and materials, equipmer.t, and plant protection aspects of operation. The safety and environmental analyses should support the conclusion that the health and safety of the public and operating personnel and the environmental values will be protected during operation if all opera-tions are performed within certain prescribed limits.

These limits are defined and established in the operating controls and limits.

Except for changes that involve license conditions or safety questions that have not been reviewed, changes may be made without amending the license.

Changes in operating controls and limits would require NRC staff review and approval before being instituted.

The operating controls and limits should be proposed by the applicant and reviewed arid issued by the NRC in the form of license conditions, including technical specifications.

10.1 Proposed Operating Controls and Limits Identify and justify the selection of those variable conditions or other items based on the design criteria of the storage system or determined, as a result of safety assessment and evaluation, to be probable subjects of operat-ing controls and limits for the system.

i The operating conttols and limits and bases proposed by the applicant should be included in this citapter of the SAR.

The operating controls and limits should be complete to the fullest extent possible.

Numerical values and other pertinent data, including the technical and operating conditions support-Ing the selection, should be provided.

For each control or limit, the applica-t ble sections that show the analysis, evaluaticn, and bases for establishing the control or limit should be referenced.

G 1

o 10-1

d Each license issued by the NRC to store spent fuel at the storage site will contain technical operating limits, conditions, and requirements imposed on the conduct of operations in the interest of the health and safety of the public.

The operating controls and limits are proposed by the applicant.

A statement of the bases or reasons for proposed controls or limits should be included in the SAR.

After review by the NRC staff, they are modified as necessary before becoming part of the license.

10.1.1 Content of Operating Controls and Limits Operating controls and limits should include both technical and adminis-trative matters.

Operating controls and limits related to technical matters should consist of those features of the storage system that are of controlling importance to safety (e.g., operating parameters, systems, or components).

In addition, operating controls and limits related to technical matters should in-clude environmental monitoring and controls or limits addressed to the attain-ment of ALARA levels of exposures.

Operating controls and limits related to administrative matters should address those organizational and functional re-quirements that are important to the achievement and maintenance of safe opera-l tion of the storage system.

10.1.2 Bases for Operating Controls and Limits When an operating control and limit has been selected, the bases for its selection and its significance to safety of operation should be defined.

This can be done by the provision of a summary statement of the technical and oper-ational considerations justifying the selection.

The SAR should show the bases used for selection of operating controls and limits.

10.2 Development of Operating Controls and Limits Refer to S 72.33, " License Conditions," of 10 CFR Part 72 for guidance on the categories of activities and conditions requiring operating controls and limits.

Additional categories may be designated by the applicant or the NRC if deemed necessary to ensure the protection of the environment or public health and safety.

10-2

10.2.1 Functional and Operating Limits, Monitoring Instruments, and Limiting k)

Control Settings Controls or limits of this category apply to operating variables that are observable and measurable (e.g., temperatures within the storage cask or evi-dence of cask leakage).

Control of such variables is directly related to the performance and integrity of equipment and confinement barriers.

10.2.2 Limiting Conditions for Operation This category of operating controls and limits covers two general classes:

(1) equipment and (2) technical conditions and characteristics of the installa-tion necessary for continued operation, as discussed below.

10.2.2.1 Equipment.

Operating controls and limits should establish the lowest acceptable level of performance for a system or component and the minimum number of components or the minimum portion of the system that should be oper-able or available.

I 10.2.2.2 Technical Conditions and Characteristics.

Technical conditions and characteristics should be stated in terms of allowable quantities, e.g.,

storage cask temperatures, radioactivity levels in gas samples, area radiation levels, or allowable configurations of equipment and speat fuel assemblies during transfer and storage operations.

10.2.3 Surveillance Requirements Major emphasis in surveillance specifications should be placed on those systems and components essential to safety during all modes of operation or necessary to prevent or mitigate the consequences of accidents.

Tests, calibrations, or inspections should verify performance and availability of important equipment and should detect incipient deficiencies.

I 10-3 i

1 e

10.2.4 Design Features O

The operating controls and limits cover design characteristics of special importance to each of the physical barriers and to the maintenance of safety margins in the design.

The principal objective of this section is to show how changes in the design of structures, systems, and components important to safety are developed, reviewed, and controlled, i.e., a description of the review and audit system for design and design changes.

10.2.5 Administrative Controls The SAR should contain a full description and discussion of organizational and administrative systems and procedures, recordkeeping, review and audit, and the reporting necessary to ensure that the operations involved in the storage of spent fuel at the storage site are performed in a safe manner.

10.2.6 Suggested Format for Operating Controls and Limits 1.

Title:

(e.g., maximum radiation level at any surface of the storage l

cask).

2.

Specification:

(limits).

3.

Applicability:

Systems er operations to which the control or limit applies should be clearly defined.

4.

Objective:

The reasons for the cont'rol or limit and the specific unsafe conditions it is intended to prevent.

5.

Action: What is to be dene if the control or limit is exceeded; clearly define specific actions.

6.

Surveillance Requirements: What maintenance and tests are to be performed and when.

7.

Bases:

The SAR should contain all pertinent information and an explicit detailed analysis and assessment supporting the choice of the item and its specific value or characteristics.

The basis for each control or limit should contain a summary of the information in sufficient depth to indi-cate the completeness and validity of the supporting information and to pro-l vide justification for the control or limit.

The following subjects may be 10-4

F]

appropriate for discussion in the bases section:

A) a.

Technical Basis.

The technical basis is derived from technical knowledge of the process ~and its characteristics and should support the choice l

of the particular variable as well as the value of the variable.

The results of computations, experiments, or judgments should be stated, and analysis and evaluation should be summarized.

b.

Equipment.

A safety limit often is protected by or closely related to certain equipment.

Such a relationship should be noted, and the means by which the variable is monitored and controlled should be stated.

For controls and limits in categories referenced in Sections 10.2.2 through 10.2.4, the bases are particularly important.

The func-tion of the equipment and how and why the requirement is selected should be noted here.

In addition, the means by which surveillance is accomplished should be noted.

If surveillance is required periodically, the basis for the frequency of the required action should be given.

c.

Operation.

The margins and the bases that relate to the safety l

l limits and the normal operating zones should be stated.

The roles of operat-ing procedures and of protective systems in guarding against exceeding a limit v

or condition should be stated.

Include a brief discussion of such factors as system responses, operational transients, malfunctions, and procedural errors.

Reference to related controls or limits should be made.

L 10-5

r

{

11.

QUALITY ASSURANCE Subpart G of Part 72 requires that a quality assurance (QA) program be established, maintained, and executed for structures, systems, and components important to safety.

The QA program to be applied to the spent fuel storage system should be described.

The applicant should identify systems and components that are important to safety and will be covered by the QA program.

The QA pro-gram should be applied to design, purchase, fabrication, handling, shipping, storing, cleaning, assembly, inspection, testing, operation, maintenance, repair, and modification of structures, systems, and components identified as important to safety.

The applicable QA criteria should be executed to an extent that is commensurate with the importance to safety.

A QA program that meets the applicable criteria in Appendix B to 10 CFR Part 50 and that has been approved by the NRC will be acceptable if it is estab-lished, maintained, and executed with regard to the spent fuel storage system.

m Prior to first use, the applicant should notify the Director, Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory Commission, Washington, DC 20555, of its intent to apply its previously approved QA program to the spent fuel storage systems.

The applicant should identify the program by date of submittal, docket number, and date of NRC approval.

A document entitled " Standard Review Plan for Quality Assurance Programs for an Independent Spent Fuel Storage Installation (ISFSI) 10 CFR 72"* has been developed by the NRC staff for implementing review of quality assurance programs submitted by applicants.

This document could be applied to a QA l

progran for an onsite spent fuel sto age system.

  • A copy of this document is available for inspection and copying for a fee at the NRC Public Document Room, 1717 H St. NW., Washington, DC, under q

Task CE 301-4.

Single copies may be obtained by writing to the Advanced Fuel

)

and Spent Fuel Licensing Branch, Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory Commission, Washington, DC 20555.

v 11-1

A DRAFT VALUE/ IMPACT STATEMENT 1.

PROPOSED ACTION 1.1 Description This proposed action is to issue " Standard Format and Content for the Safety Analysis Report (SAR) for Onsite Storage of Spent Fuel Casks" as a draft regula-tory guide for comment.

The guide would set forth the type of information needed for preparation and submittal of an SAR for storage of spent fuel in casks, par-ticularly at a nuclear power reactor site.

1.2 Need for Proposed Action m

\\

/

There is an increasing need for additional capacity for storage of spent v

fuel. Storage of spent fuel in casks is an alternative, chosen by several power reactor licensees, to the use of water-basin storage.

This draft guide provides guidance for preparation of the SAR for storage of spent fuel in casks.

The proposed action is timely and would expedite licensing related to storage of spent fuel.

1. 3 Value/ Impact of Proposed Action 1.3.1 NRC The draft guide would provide a format and set forth information needed by the NRC staff when reviewing an SAR for a spent fuel storage system, which would ensure more complete and efficient review.

1.3.2 Other Government Agencies The guidance would be applicable to applications submitted by DOE, or any other government agency, for storage of spent fuel in casks.

O VI-1

1.3.3 Industry No increased effort or cost to applicants for a license to store spent fuel is anticipated as a result of this proposed action.

Submittal of an SAR is required by regulation under S 72.15 of 10 CFR Part 72.

It is likely that the proposed action will result in reduced time and effort in developing the SAR in applications for a license to store spent fuel.

It is also likely that the proposed action will result in expedited license reviews because the SAR will be more complete when submitted, thus avoiding unnecessary communications between applicants and the NRC staff.

1.3.4 Workers The principle of ALARA as applied to occupational exposure is addressed.

1.3.5 Public The protection of the health and safety of the public is a ma,ior topic in this draft guide.

1.4 Decision On Proposed Action l

The draft regulatory guide is consistent with established NRC policy and practice and should be issued for comment.

2.

TECHNICAL APPROACH The contents of this draft guide are not technical in nature so this sec-tion is not applicable.

3.

PROCEDURAL APPROACH Several methods were considered for making the proposed guidance available, e.g., NUREG-series report, branch technical position, and regulatory guide.

A draft regulatory guide was selected as the best alternative for this proposed action.

This procedure is most effective and allows for public participation in the development of an active regulatory guide.

VI-2

4.

STATUTORY CONSIDERATIONS 4.1 NRC Authority Authority for this proposed action is derived from the Atomic Energy Act of 1954, as amended, the Energy Reorganization Act of 1974, as amended, the Nuclear Waste Policy Act of 1982, and is implemented through the Commission's regulations in Title 10 of the Code of Federal Regulations, as cited in the introduction to the guide.

4.2 Need for NEPA Assessment Issuance or amendment of guides for the implementation of regulations in Title 10, Chapter I, of the Code of Federal Regulations is a categorical exclu-sion under paragraph 51.22(c)(16) of 10 CFR Part 51.

Thus, an environmental im-pact statement or assessment is not required for this action.

m 5.

RELATIONSHIP TO OTHER EXISTING OR PROPOSED REGULATIONS OR POLICIES

)

v An active guide that would be revised as a result of public comments would be issued under regulations in 10 CFR Part 72.

6.

SUtHARY AND CONCLUSION A draft regulatory guide should be prepared to provide guidance for the format and content of an SAR for storage of spent fuel in casks at a nuclear power reactor site.

O VI-3