APPENDIX A NOTICE OF VIOLATION Reed College License No. R-112 Docket No. 50-288 As a result of the inspection during the period June 23-24, 1986 and in accordance with NRC Enforcement Policy 10 CFR, Part 2, Appendix C, the following violations were identified:
i A).
Technical Specifications, Section F.9.(a) requires at least a semi-annual verification that all control element drop times are less than one second.
Contrary to the above', verification of control element drop times were not performed for approximately a one year period ranging from February 7, 1985 through January 21, 1986.
This is a Severity Level IV Violation (Supplement 1).
B).
Technical Specifications,Section I.2 requires that the Radiaticn Safety Committee membership shall be composed of faculty members and members from outside the organization who are not connected with the operation of the reactor facility.
Contrary to the above, an individual who has been connected with the operation of reactor facility as a licensed operator has been a member of the Radiation Safety Committee from 2 April 1983 through 2 April 1985.
This is a Severity Level V Violation (Supplement 1).
C).
10 CFR Part 50.54 " Conditions of Licenses" states in part (1-1) that
" Holders of operating licenses in effect on September 17, 1973 shall implement an operator requalification program which, as a minimum, meets the requirements of Appendix A of Part 55 of this chapter which was submitted for approval by the Atomic Energy Commission."
The licensee's NRC approved operator requalification program, revised on November 27, 1980, requires:
(1) The Director will select a qualified senior reactor operator (SRO) to write and administer reactor operator (RO) and (SRO) requalification examinations.
Contrary to the above, an RO was assigned to prepare and administer the 1985 annual reactor operators examination.
j This is a Severity Level V Violation (Supplement 1).
I Og7210235860716 G
ADOCK ogjoopgg PDR
. Pursuant to the provisions of 10 CFR 2.201, Reed College is hereby required to submit to this office withi:1 thirty days of the date of this Notice, a written statement or explanation addressing each alleged violation and including:
(1)-
the corrective steps which have been taken and the results achieved; (2) corrective steps which will be taken to avoid further violations;.(3) the date~
when full compliance will be achieved.
Consideration may be given to extending your response time for good cause shown.
JUL 161986
, May Dated R. A. Scarano, Di' rector fL Division of Radiation Safety and Safeguards f
.