ML20203C987
| ML20203C987 | |
| Person / Time | |
|---|---|
| Site: | Palisades |
| Issue date: | 07/10/1986 |
| From: | Berry K CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.) |
| To: | James Keppler NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| References | |
| NUDOCS 8607210114 | |
| Download: ML20203C987 (5) | |
Text
b m (d e
Consumers POW 80 x
,n w,,,
5 h
ar Licensing mmunaws enaanuss General Offices: 1945 West Parnall Road. Jackson, MI 49201 e (517) 788-1636 paionitY RO'JTI M July 10, 1986 p
y
.m Q ds !
A I
b,
[
FIL James G Keppler, Administrator Region III US Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137 DOCKET 50-255 - LICENSE DPR PALISADES PLANT -
FIRE PROTECTION - ADDITIONAL INFORMATION REQUESTED FOR THE JULY 28, 1986 COMPLIANCE INSPECTION NRC letter dated May 29, 1986 confirmed that the Palisades Plant would be inspected on July 28 - August 1, 1986 for compliance with 10CFR50, Appendix R.
In addition, the May 29, 1986 NRC letter requested Consumers Power Company to provide, by July 14, 1986, additional information to enable proper NRC preparation for and performance of that inspection. Eleven (11) categories of additional information were enumerated and requested by the May 29, 1986 NRC letter; and, to further assist the inspection effort, the letter requested a summary list of deviations / exemptions requested and granted or requested and pending.
This letter transmits the requested information in the form of attachments.
Attachment A is an index to the numerically designated attachments 1-12. provides the information requested as Item I in the May 29, 1986 NRC letter, Attachment 2 provides the information requested as Item 2, and so forth through Item 11.
A summary of deviations / exemptions granted or pending is included as Attachment 12.
8607210114 860710 JUL 11 $b0 PDR ADOCK 05000255 F
PDR OC0786-0105-NLO4 1
I Iso /
eg J G Keppler, Administrator, 2
Palisades Plant Fire Protection - Compliance Inspection July 10, 1986 Because of the volume of material required to present the requested additional information, the two shipping cases accompanying this letter contain the numerically designated attachments to it and are the only copies of those attachments being forwarded to the NRC.
- '/nf mAu ToK Kenneth W Berry Director, Nuclear Licensing CC Director, Office of NRR (w/o numerically designated attachments)
Director, Office of I & E (w/o numerically designated attachments)
NRC Resident Inspector - Palisades (w/o numerically designated attachments)
Attachments l
OC0786-0105-NLO4 i
i
ATTACHMENT A Consumers Power Company Palisades Plant Docket 50-255 ADDITIONAL INFORMATION REQUESTED BY NRC LETTER DATED MAY 29, 1986 TO ENABLE PROPER NRC PREPARATION FOR AND PERFORMANCE OF THE 10CFR50 APPENDIX R COMPLIANCE INSPECTION SCHEDULED FOR JULY 28 - AUGUST 1, 1986 INDEX TO THE NUMERICALLY DESIGNATED ATTACHMENTS TO THE JULY 10, 1986 CONSUMERS POWER COMPANY FIRE PROTECTION SUBMITTAL TO REGION III 2 Pages MIO786-0105B-NLO4
4 Attachment A - Index 1
4 1
INDEX TO THE NUMERICALLY DESIGNATED ATTACHMENTS TO THE JULY 10, 1986 l
LETTER TO REGION III I
Piping and instrumentation (flow) diagrams for hot standby (shutdown) and cold shutdown systems, alternative or dedicated shutdown systems and the reactor coolant pump oil collection system.
4 Plant layout and equipment location drawings which 1
identify the physical plant locations of hot standby j
(shutdown) and cold shutdown equipment.
Clearly marked-up electrical raceway drawings which j
identify the cable routing of power and control circuits i
for those plant systeis necessary to achieve and maintain hot standby ' shutdown). Drawings also identify exactly where cabla. capping has been installed and the extent to which cable wrapping has been installed and identify the equipment and cabling which is redundant or alternative to the cabling that has been wrapped.
Control electrical distribution diagrams, control schemes i
i for shutdown components which are being controlled from the remote shutdown panel, and single line AC and DC power.
4 f
Plant layout drawings which identify fire area delineation and fire protection equipment locations.
Marked-up plant layout drawings which identify the i
locations of emergency lighting units.
1 Associated drawings which depict the physical and seismic l
design of reactor coolant pump oil collection system.
Associated circuit analysis including drawing of alternate shutdown panel, circuits and fuse coordination.
Plant Operating Procedures which describe normal hot and 1
cold shutdown from inside the control room, emergency hot and cold shutdown from emergency control stations outside j
i and independent of the control room, and shutdown j
operations which utilize alternative or dedicated shutdown capability and natural circulation.
i Fire damage control and repair procedures for cold 0 shutdown systems.
MIO786-0105B-NLO4
i Attachment A - Index 2
t Safe Shutdown Analysis (SSA) and current Fire Hazards 1 Analysis (FHA).
A summary of deviations / exemptions granted, pending or 2 denied.
i l
I J
i t
1 j
i
.4 i
l 1
4 a
i t
)
1 HIO786-0105B-NLO4 h
--..--e--
~-.-,,-,--.e,
--n.
,~n~-..
.. - -,