I l
I t
APPENDIX B l
NOTICE OF VIOLATION Cintichem, Inc.
Docket Nos. 50-54 and 70-687 Tuxedo, New York 10987 License Nos. R-81 and SNM-639 As a result of the inspection conducted on February 10-14, 1986, and in accord-ance with the NRC Enforcement Policy (10 CFR 2, Appendix C), the following violations were identified:
A.
License Condition 9.1 of Safeguards Amendment SG-1, dated April 12, 1985, states that the licensee shall maintain and fully implement all provi-sions of the Comission approved security plan titled, " Physical Security Plan for the Union Carbide Corporation Facility at Tuxedo, New York, Revision 3 and 4," dated April 30, 1983, and May 19, 1983, respectively; and as revised in accordance with the provisions of 10 CFR 70.32 (e).
10 CFR 70.32(e) states, in part, that the licensee shall maintain records of changes to the plan made without prior Commission approval for a period of two years from the date of the change, and shall furnish to the Com-mission, a report containing a description of each change within two months after the change is made.
Contrary to the above, on February 13, 1986, the inspector identified that the licensee had made changes on January 31, 1985, and November 1, 1985, but had not furnished to the Commission, a report containing a description of each change within two months after the change was made.
Examples of the changes made are as follows:
T!!!S FAPfettPF CONTAINS SA E0lMHD1 a.
lilFORWJ0;: "' i3 NOT F0", Pi 0 llc DISCLU3EE,liid idiENT!CNALLY LEFT ELAIM.
b.
TiHS PAMAFM CONTMNS SAFWMUDS INF0Wi'Oi: f,9 3 00T FOR PZLIC DISCLUSS3E,li $ !NTENil0:lALLY LEFT DLA;G.
c.
Job titles of certain positions, as stated on page 3.4 and page 4.1 of the Physical Security Plan, had been changed on November 1, 1985.
8604210248 860414 PDR ADOCK 05000054 G
Appendix B 2
From
_T_o; o
Plant Manager, Radiochcmicals Plant Manger Nuclear Facility Services Engineer Hot Lab Operations Supervisor Manager, Engineering and Maintenance Manager, Engineering and Technology Sales This is a Severity Level V violation (Supplement III, E).
B.
Tills PAPAGRAPH CONTAINS SAFEGUARD 5 INFOT&inI:0N M3 6 !!DI FOR PUBLIC DISCLUSUEE,islS !.4IENIiONALLY LEFT BLAN!(,
This is a Severity Level V violation (Supplement III, E).
C.
r Tills PA A0i'?JH CONTAINS SAFEGUARDS INF0WiAi G" f G iS M0T F0?. PUBLIC CISCLOCJRE,liIS iHIENTIONALLY LEFT DLANii.
This is a Severity. Level V violation (Supplement III, E).
Pursuant to the provisions of 10 CFR 2.201, Cintichem, Inc. is hereby required to submit to this office within thirty days of the date of the letter which transmitted this Notice, a written statement or explanation in reply,
-including: (1) the corrective steps which have been taken and the results achieved; (2) corrective steps which will be taken to avoid further violations; and (3) the date when full compliance will be achieved. Where good cause is shown, consideration will be given to extending this response time.
I