4 JUL 151996 DISTRIBUTION:
PDR LPDR Reg Files RMDiggs Docket Nos. 50-321 GRivenbark, BWD-2 and 50-366 SNorris, BWD-2 LFMS Check File LFMS Reactor File Georgia Power Company LFMS R/F ATTN: Mr. J. T. Beckham, Jr.
DW/LT/ Georgia Vice President Nuclear Generation P.O. Box 4545-Atlanta, GA 30302 Gentlemen:
The Office of Nuclear Reactor Regulation (0NRR) staff have completed their fee determinations with respect to various old applications filed by your Company relating to inservice inspection and testing programs, requests for relief from certain ASME Code requirements and related Technical Specification changes for the Edwin I. Hatch Nuclear Plant Unit Nos. 1 and 2.
Based on data provided to us, we find that a total of $38,500 is due the NRC for the reviews associated with the numerous ISI/IST related requests and supplements filed by your Company. The enclosed list reflects each request, any fees paid, fees due, and the ONRR staff's final fee determination and action on each.
It is requested that your Company remit the sum of $38,500 to our office for fees currently due for the ISI/IST requests.
Please accept our apology for the lateness of our notification of final fees due on these old ISI/IST applications.
Sincerely, see, c. nu: tc:my, a C. James Holloway, Jr.
Acting Director License Fee Management Staff Office of Administration
Enclosure:
List of Appls. and Fees 8607180094 860715 PDR ADDCK 05000321 P
' 'bFM5: ADM
- LFMS NDM OFFICE :L ADM
_a
/Rkhf2fh-______:
SURNAME.
p
- C way :
7/ /5k86
- 7/ /JG'/86
- 7/
/86 DATE :
I f
Ar m..
m.
m
s 3
List of Applications and Fees Edwin I. Hatch Nuclear Plant Unit Nos. 1 and 2 Docket Nos. 50-321/366 Fees ONRR's Fee Application Date Fees Paid Applicable Determination & Action 8/3/78 as supplemented.
$4,000 with
$12,700 Complex issue and dupli-inservice inspection program 7/11/79 ltr cate unit. Approved by and requests for relief.
ltr and SE 7/2G '83.
10/3/78, supp. 8/1/85.
4,000 12,300 Several safety issues.
TS changes re inservice Partially approved by l
inspection for Unit No. 1.
Amd. No. 119 on 12/23/85.
I 11/18/81 Relief from regmt None 4,400 Single safety issue and for volumetric examination duplicate unit. Approved of Category B-K-1 welded by letter dated 1/27/82.
supports.
3/2/82 Relief from visual None 4,400 Single safety issue and inspection of Category duplicate unit. Approved B-K-2, C-E-2, and Subsection by letter dated 3/12/82.
i IWD-2400 Class 3 supports.
l 3/11/82 Relief from hydro-None 4,400 Single safety issue and static minimum test temperature.
duplicate unit. Approved i
by letter dated 4/7/82.
8/12/83 Inservice testing 4,400 12,700 Complex issue and dupli-program and requests for cate unit. Approved by I
relief.
letter and SE on 6/4/85.
No review to be done on ISI portion because superseded on 6/25/85.
I TOTAL FEES APPLICABLE.. $50,900 TOTAL FEES PAID..... 12,400 FEES DUE USNRC...... $38,500
[