July 10, 1986 Distribution Docket No. 50-285
[(Docket _ File, 7 NThompson NRC PDR DSells Local PDR PKreutzer Mr. R. L. Andrews PD#8 Reading ACRS (10)
Division Manager - Nuclear Production FMiraglia OELD Omaha Public Power District EJordan BGrimes 1623 Harney Street Branch File 3.3a JPartlow Omaha, Nebraska 68102
Dear Mr. Andrews:
SUBJECT:
GENERIC LETTER 83-28, ITEM 4.5.1 - REACTOR TRIP SYSTEM RELIABILITY (SYSTEM FUNCTIONAL TESTING - TEST DESCRIPTION)
The statf has completed its review of Reactor Trip System Reliability (System Functional Testing - Test Description) for the Fort Calhoun Station, Unit No. 1.
Our review was based on your November 4, 1983 response to our July 8, 1983 Generic Letter entitled " Required Actions Based on Generic Implications of Salem ATWS Events."
Based upon our review of the above referenced submittal, we conclude that your response to GL 83-28, Item 4.5.1, is acceptable and we consider our review for this item complete.
Our safety evaluation is enclosed.
Sincerely, O
(
jb A Donald E. Sells, Project Manager PWR Project Directorate #8 U
Division of PWR Licensing-B
Enclosure:
As stated cc w/ enclosure:
See next page
<?,"Eh PD#8:
PD#8:
PD#8.
PK7gutzer DSellsi*jch AThadani 7/y/86 7/\\ Cf86 7/jO/86 1607160254 860710 1
PDR ADOCK 05000205 p
l Mr. R. L. Andrews Fort Calhoun Station Omaha Public Power District Unit No. 1 cc:
Harry H. Voigt, Esq.
LeBoeuf, Lamb, Leiby & MacRae 1333 New Hampshire Avenue, NW Washington, D.C.
20036 l
Mr. Jack Jensen, Chairman Washington County Board of Supervisors Blair, Nebraska 68008 Metropolitan Planning Agency ATTN:
Dagnia Prieditis 7000 West Center Road Omaha, Nebraska 68107 Mr. Phillip Harrell, Resident Inspector
- U.S. Nuclear Regulatory Commission P. O. Box 309 Fort Calhoun, Nebraska 68023 Mr. Charles B. Brinkman, Manager Washington Nuclear Operations C-E Power Systems 7910 Woodmont Avenue Bethesda, Maryland 20814 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission Office of Executive Director for Operations 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011
)