ML20202D441

From kanterella
Jump to navigation Jump to search
Certificate of Compliance 9006,Rev 9,for Model Ai 500 Su. Approval Record Encl
ML20202D441
Person / Time
Site: 07109006
Issue date: 07/03/1986
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To:
Shared Package
ML20202D433 List:
References
NUDOCS 8607140133
Download: ML20202D441 (3)


Text

..,________________________________.______________________y

~ l NnCFORMSie U.S. NUCLEAR REGULATORY COMMISSION N I

==

CERTIFICATE CF CEPLIANCE I

I so crR n FOR RADl! ACTIVE MATERIALS PACKA7ES I

1.s CE..TIFICATE NUMBER b Revision NUMBER

c. PACKAGE IDENTIFICATION NUMBER d PAGE NUMBER
e. ToTAt NUMBER PAGES i

9006 9

USA /9006/B(U) 1 2

y I

z PREAustE P

l

a. This certificate is issued to certify that the packagmg and contents descnbed in item 5 below, eneets the applicable safety standards set forth in Title 10. Coda b

g of Federal Regulations, Part 71, ~ Packaging and Transportation of Radeoactive Material?

l I

b. This certificate does not reheve the consignor from comphance with any requerement of the regulations of the U S. Department of Transportation or other k

I apphcable regulatory agencies, including the government of any country through or into which the package will be transported.

I I

E I

N i

N ar Rrigic,ATys issgUoN rsE sAsis or A s4FErv ANAtysis,REgigt,sgggN oyR p

c 1

R i

Amersham Corporation Tech / Ops Inc. application p

I 40 North Avenue dated March 31, 1986.

N I

Burlington, MA 01803 5

I I

I I

I

'71-9006

c. COCKhr NUMBER k

I E

a coNoitioNs N

This certificate is conditional upon fulfishng the requirements of 10 CFR Part 7t, as applicable, and the conditions specified below.

I i

I q

s i

g (a) Packaging y

. I p

I (1) Model No.:

AI 500 SU i

N

.R l

(2) Desc ription,

l 1

W p

A radiographic source changer consisting of a welded 10-ghge stainless p

I steel box, approximately 5" wide x,6" high x 11" long. The source p

{

changer has a positive closure hinged flat plate cover and a depleted i

l 4

uranium shield. Two titanium tubes are' positioned in the center of N.

l the depleted. uranium and house the '. source capsules and the source l

cable assemblies.

The two openings are closed by locking assemblies g

y g

and threaded caps. The gross weight is approximately 65 pounds.

W i

is 1

(3) Drawi ngs E

4 E

3 The packaging is constructed in accordance with Tech / Ops, Inc.

l Drawing Nos. AIS00SU90,- Sheets 1 through 7 of 7, Rev. B; AIS00SU91, y

Sheets 1 and 2 of 2; AIS00SU92; and optional Drawing No. AIS00SU93, g

Rev. A.

q i

is I

(b) Contents n

l W

l (1) Type and form of material l

l F

l Iridium 192 as a sealed source which meets the requirements of special p

l form radioactive material, t

i R

I (2) Maximun quantity of material per package i

I I

l 120 curies l

l 1

I I

I i

i I

i PD$

_I

I j

"2" l

CONDITIONS (continued) 13 C NUCLE.1R FiEGULATORY C0YWSslON g

I I

I N

l Page 2 - Certificate No. 9006 - Revision No. 9 - Docket No. 71-9006 l

l N

I a

l l

l 6.

The source shall be positioned within the titanium tubing by a source cable n

assembly which meets the parameters shown in Tech / Ops, Inc. Drawing Hos. 42402-l l

1, Rev. F, and 42402-4, Rev. B.

l,

I i

l 7.

The name plate shall be fabricated of materials capable of resisting the fire p

I test of 10 CFR Part 71 and maintaining its legibility.

i l

i l

8.

The package authorized by this certificate is hereby approved for use under the l

l general license provisions of 10 CFR $71.12.

g i

n QlA;4 'qg-CJ(/,

i 9.

Expiration date: May 31,1990.. O C/s, g

I H

i s.-

s,7 A l

k,J ~

REFERENCES N

.T

' r3 G,

4 i

Tech / Ops, Inc. application dated March 31, 1986.

" 7, l

)

s a.. - '

N!

FOR THE' U.S. HUCLEAR REGULATORY COMMISSION E;

i C

N 3

/ a

()

E.

(.I:;3 l

k

, x.

n.

[

9, p

L F'

s E.

t,sn..

g g=

e

C.

es.

acDona hie E!

F G

~

Transportation Certification Branch R

l' Division of Fuel Cycle and 4

i

' Material Safety,,INSS l

)

q s

4 Date:

JUL 0 31986 i.

b j

~

8 A

W W

4 o p'

s v

H i

i i

e M

N 8

p i

s s

4 W

k I

d u

I l

1 i

l 1


__,,w_,,___,,______________,,,,,,_.,

'o,,

UNITED STATES 8

NUCLEAR REGULATORY COMMISSION o

r, a

wAsumorow. o. c. 20sss e

Transportation Certification Branch Approval Record Model No. AI 500 SU Package Docket No. 71-9006 By letter dated August 12, 1985, as supplemented March 31, 1986, Tech / Ops RPD, Inc. requested an amendment to Certificate of Compliance No. 9006 for modification of the lock box.

Except for the lock box, all other aspects of the package are consistent with the original design.

To demonstrate adequacy of the nodified (larger) lock box with the requirements of Part 71, the applicant conducted an additional series of 30-foot drop and puncture tests of the package. For the 30-foot drop test, the package impacted on the cover plate over the lock box nechanism.

Following the 30-foot drop test, the package was dropped three times onto the puncture pin per 10 CFR Part 71.

Two of the puncture tests were conducted without the protection of the cover plate and the lock box impacted directly on the puncture pin. A shielding test conducted by the applicant indicated that the combination of 30-foot drop and puncture tests did not reduce the shielding efficiency of the package.

Based on our review of the tests and results, we have concluded that the lock box modification to the Model No. AI 500 SU package design meets '

the requirements of 10 CFR Part 71.

Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety, INSS Date: JW. 0 3 5 o

9 t

i 5