t January 27, 1999 Mr. Richard L. Hdm, Rcactor Adminiatator University of Illinois at Urbana-Chanpaign Department of Nuclear Engineering Radiation Science Laborato.fy 214 Nuclear Engineering Laboratory 103 South Goodwin Avenue.

Urbana, Illinois 61801-2984

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION (TAC NO. MA4177)

Dear Mr. Holm:

We are continuing our review of your amendment request for Facility License No. R-115 for the University of Illinois at Urbana-Champaign Advanced TRIGA Reactor that you submitted on October 5,1998. During our review of your amendment request, questions have arisen for which we require additionalinformation and clarification. Please provide responses to the enclosed request for additionalinformation within 30 days of the date of this letter. In accordance with 10 CFR 50.30(b), your response must be executed in a signed original under oath or affirmation. Following receipt of the additionalinformation, we will continue our evaluation of your amendment request.

If you have any questions regarding this review, please contact me at (301) 415-1127.

Sincerely, ORIGINAL SIGNED BY:

Alexander Adams, Jr., Senior Project Manager Non-Power ieactors and Decommissioning r

Project Directorate Division of Reactor Program Management Office of Nuclear Reactor Regulation Docket No. 50-151

Enclosure:

As stated cc w/ enclosure:

See next page l

DISTRIBUTION:

(

E-Mall HARD COPY j

CBassett SHolmes Docket File 50151 DMatthews i

TBurdick Pisaac PUBLIC SWeiss

' PDoyle MMendonca OGC (015-B18)

AAdams I

WEresian TMichaels EHylton PDND r/f PDND M P

YX /

,. 0 AAd E

n SWeiss l M/99

/ $7/99

(

/99 OFFICIAL RECORD COPY DOCUMENT NAME: G:\\SECY% DAMS \\RAIM4177 9902010201 990123

.g 2'.

UNITED STATES l-

.j NUCLEAR REGULATORY COMMISSION

'C WASHINGTON. o.C. 20E4001 f

.....,o January 27, 1999 Mr. Richard L. Holm, Reactor Administrator University of Illinois at Urbana-Champaign Department of Nuclear Engineering Radiation Science Laboratory 214 Nuclear Engineering Laboratory 103 South Goodwin Avenue Urbana, !!linois 61801-2984

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION (TAC NO. MA4177)

Dear Mr. Holm:

1 We are continuing our review of your amendment request for Facility License No. R-115 for the University of Illinois at Urbana-Champaign Advanced TRIGA Reactor that you submitted on October 5,1998. During our review of your amendment request, questions have arisen for which we require additionalinformation and clarification. Please provide responses to the enclosed request for additionalinformation within 30 days of the date of this letter. In accordance with 10 CFR 50.30(b), your response must be executed in a signed original under oath or affirmation. Following receipt of the additional information, we will continue our evaluation of your amendment request, if you have any questions regarding this review, p' ease contact me at (301) 4151127.

Sincerely, ad Alexander Adams, Jr.,

nior Project Manager Non-Power Reactors and Decommdsioning Project Directorate Division of Reactor Program Management Office of Nuclear Reactor Regulation Docket No. 50-151

Enclosure:

As stated cc w/ enclosure:

See next page

l I

1 1

University of Illinois Docket Nos. 50-151/356 cc:

The Honorable Tod Satterthwaite Mayor of the City of Urbana P. O. Box 219 Urbana, IL 61803 i

Illinois Department of Nuclear Safety Manager, Office of Nuclear Facility Safety j

1035 Outer Park Drive Springfield, IL 62705 Dr. Barclay G. Jones, Head j

Department of Nuclear Engineering University of lilinois at Urbana-Champaign 103 South Goodwin Avenue i

Urbana, IL 61801-2984

-a h'

1 ENCLOSURE REQUEST FOR ADDITIONAL INFORMATION UNIVERSITY OF ILLINOIS AT URBANA-CHAMPAIGN ADVANCED TRIGA REACTOR DOCKET NO. 50-151 1.

TS 4.7 d. Your proposed TS refers to fuel element storage in the suberitical l

assembly, wet storage racks and Bulk Shielding Facility. To match the wording used in TS 3.9, would it be simpler to say fuel element storage in the Bulk Shielding Facility and TRIGA pool? Please explain the purpose of moving fuel elements to "other storage."

2.

TS 4.7 f. This TS refers to checking poollevelin the Bulk Shielding Facility.

Should this TS also refer to the TRIGA pool when it is used for fuel storage?

3.

TS 6.2.1 c. This TS refers to reactor operating staff. Please propose wording that reflects the permanent shutdown status of the facility.

l

<