i s 21 m n.
7/- 0&of
~,
30-JP-2 i
STANDARD PROCEDURE Proc. No.
10-m-71 Date issued 3/28/73 Date Revised 1/30/79 RADIATION PROTECTION OFFICER DUTIES Date Revised omsen er unent morous Approved By
[bN sasmas innuunt mon punt RETURN TO 396-SS
" " "a'a,.
snenns. ir.n. inn saisi Po9 1
or 2
SCOPE To define the Job duties of the Radiation Protection Officer at the Saginaw Plant.
PURPOSE To insure compliance with all N.R.C.
regulations.
1.
Supervise radiographer to insure that radiographer duty assignments are maintained.
2.
Act in advisory capacity to licensee's nanagement and radiographic personnel.
3.
Serve as the licensee's liaison officer with the N.R.C.
on license matters.
4.
Maintain control of procurement and disposal of licence by-product material and administrate the Quality Assurance Program.
5.
Conduct quarterly internal radiographic inspections.
6.
Supervise the licensee's record keeping system.
7.
Assume control and institute corrective action in emergency situations.
8.
Investigate causes of incidents and determino necessary preventive action.
9.
Establish and maintain up to date operating and emergency pr cedures.
10.
Report to employees and former employees of radiation exposure.
(Title
~
10, Part 20, Section 20.404, 5,. 7,
& 8) u 11.
Maintain.<the following regulations on file in the Cobalt BuFlding.
a.
Current N.R.C.
Regulations b
ih b.
Safety Operating and Emergency Procedures c.
Current N.R.C.
License d.
N.R.C.
Form 3 Posted 12.
Supervise and assist in conducting periodic training and on-the-job training for radiographers.
Initial training is conducted at G.M.I.
Engineering & Management Institute in Flint, Michigan or other approved schools which'all radiographers have attended.
8607110324 860620 PDR ADOCK 071*****
C PDR IJc cm (g," "," # "
O INDICATES REVISED PORTION
< a %-
J76>
F g
7 e
DOCKET NO.
7/~
CONTROL NO. --
W DATE OF 000. -
I Md b
DATE RCVD. _ _b b
FCUF PDR --
FCAF _ _.
LPOR -
l& E REF. -
SAFEGUARDS _ _.
FCIC OniER _
DATE. 7d INITIAL-bk,
d
I 7/ d86 6/20/86 4
Mr.' MacDonald:
1 Included, per your request, is our Quality Assurance Program l
(in triplicate) and a check for
$150.00.
l f) l
-n?['
1 i
John C. Roth Radiation Protection cs Officer D
l g
i I
RECENED 3 L
y go\\sss N D 7/5.L,
"(
R REGuWOW e
3 g
' ' O.S MU iss10M j
g MMSS i