Mr. Rind:ll K. Edingte.. -
Jrnu:ry 26, 1999 I
Vics Presid:nt - Op: rations Entergy Operations, Inc.
River Bend Station P. O. Box 220
- St. Francisville, LA 70775
SUBJECT:
RIVER BEND STATION, UNIT 1 - PETITION OF THE UNION OF CONCERNED SCIENTISTS (UCS) PURSUANT TO 10 CFR 2.206; NOTICE OF INFORMAL PUBLIC HEARING (TAC NO. MA3669)
Dear Mr. Edington:
By letter dated December 1,1998, the Nuclear Regulatory Commission (NRC) requested that Entergy Operations, Inc. (EOl), provide a written response to the issues raised in a petition filed by the Union of Concerned Scientists (UCS) under 10 CFR 2.206 on September 25,1998. The letter requested that this information be provided within 30 days from the date of receipt. The response had been expected on or about the end of January 1999. In recent conversations between NRR and representatives from the Perry Nuclear Power Plant (PNPP), the PNPP licensee requested an additional 2 to 3 weeks to complete its response, citing the need for more time to address the specific issues raised in the UCS Petition. As a result, the NRC is i
granting the PNPP licensee and EOl an additional 11 calender days to complete its written I
response, and is extending the due date to February 11,1999.
It is important that the NRC receive your response in a timely manner in order to ensure that all participants in the informal public hearing process are better prepared to focus on the fuel cladding integrity issues raised in the River Bend Station and Perry Nuclear Power Plant Petitions. If there are any questions regarding your written response, please contact Mr. Robert Fretz at (301) 415-1324.
Sincerely.
ORIGINAL SIGNED BY:
Robert J. Fretz, Project Manager Project Directorate IV-1 Division of Reactor Projects Ill/IV Office of Nuclear Reactor Regulation Docket No. 50-458 O
cc: See ne4 page DISTRIBUTION:
2\\
O'f Sede$49e PUBLIC PD4-1 r/f C.Hawes R. Fretz L. Hurley, RIV ACRS OGC (15B18)
E. Adensam (EGA1)
J.Hannon Documengamej G:\\RBFINAL\\LT211EOl.WPD, /
OFC PM/PD4 "T LA/PD4-1 PD/PDb RFretz/vwb NAME JHannon DATE
//7 /99 l/ % /99 f dk/99 COPY MNO.
hO khO C h h ((~" ~ Q'"3V OFFICIAL RGCOND COPV 9902010117'990126 d P PDR ADOCK 05000458 P
purig a
t UNITED STATES l-j NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 3066H001 l
r" January 26, 1999 Mr. Randall K. Edington Vice President - Operations i
Entergy Operations, Inc.
River Bend Station P. O. Box 220 St. Francisville, LA 70775
SUBJECT:
RIVER BEND STATION, UNIT 1 - PETITION OF THE UNION OF CONCERNED SCIENTISTS (UCS) PURSUANT TO 10 CFR 2.206; NOTICE OF INFORMAL PUBLIC HEARING (TAC NO. MA3669)
Dear Mr. Edington:
By letter dated December 1,1998, the Nuclear Regulatory Commission (NRC) requested that i
Entergy Operations, Inc. (EOI), provide a written response to the issues raised in a petition filed by the Union of Concerned Scientists (UCS) under 10 CFR 2.206 on September 25,1998. The letter requested that this information be provided within 30 days from the date of receipt. The response had been expected on or about the end of January 1999. In recent conversations between NRR and representatives from the Peny Nuclear Power Plant (PNPP), the PNPP i
licensee requested an additional 2 to 3 weeks to complete its response, citing the need for more time to address the specific issues raised in the UCS Petition. As a result, the NRC is granting the PNPP licensee and EOl an additional 11 calender days to complete its written response, and is extending the due date to February 11,1999.
It is important that the NRC receive your response in a timely manner in order to ensure that all participants in the informal public hearing process are better prepared to focus on the fuel cladding integrity issues raised in the River Bend Station and Perry Nuclear Power Plant Petitions. If there are any questions regarding your written response, please contact Mr. Robert Fretz at (301) 415-1324.
Sincerely, Robert J. Fretz, Project Manager Project Directorate IV-1 Division of Reactor Projects ill/IV
- Office of Nuclear Reactor Regulation Docket No. 50-458 cc: See next page
>m
e t
Mr. Randall K. Edington Entergy Operations, Inc.
River Bend Station
.j cc:
Winston & Strawn Executive Vice President and 1400 L Street, N.W.
Chief Operating Officer Washington, DC 20005-3502 Entergy Operations, Inc.
P. O. Box 31995 Manager-Licensing Jackson, MS 39286 Entergy Operations, Inc.
River Bend Station General Manager-Plant Operations P. O. Box 220 Entergy Operations, Inc.
St. Francisville, LA 70775 River Bend Station P. O. Box 220 Senior Resident inspector St. Francisville, LA 70775 P. O. Box 1050 St. Francisville, LA 70775 Director - Nuclear Safety Entergy Operations, Inc.
President of West Feliciana River Bend Station Police Jury P. O. Box 220 P. O. Box 1921 St. Francisville, LA 70775 St. Francisville, LA 70775 Vice President - Operations Support Regional Administrator, Region IV Entergy Operations, Inc.
U.S. Nuclear Regulatory Commission P. O. Box 31995 -
611 Ryan Plaza Drive, Suite 1000 Jackson, MS 39286-1995 Arlington,TX 76011 Attorney Ceneral Ms. H. Anne Plettinger State of Louisiana
' 3456 Villa Rose Drive P. O. Box 94095 Baton Rouge, LA 70806 Baton Rouge, LA 70804-9095
- Administrator Wise, Carter, Child & Caraway Louisiana Radiation Protection Division P. O. Box 651 P. O. Box 82135 Jackson, MS 39205 Baton Rouge, LA 70884-2135 1