ML20202B479
| ML20202B479 | |
| Person / Time | |
|---|---|
| Site: | 07000036 |
| Issue date: | 01/26/1999 |
| From: | Hiland P NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | Kaiser B ABB COMBUSTION ENGINEERING NUCLEAR FUEL (FORMERLY |
| References | |
| 70-0036-98-04, 70-36-98-4, NUDOCS 9901290092 | |
| Download: ML20202B479 (2) | |
Text
- _.-
January 26,.1999' i
, - Dr. Bruce Kaiser T L Vice President, Fuel Operations l
ABB Combustion Engineering, Inc.
l 3300 State Road P i
Hematite, MO 63047
)
SUBJECT:
RESPONSE TO COMBUSTION ENGINEERING INSPECTION REPORT 070-00036/98004(DNMS)-
l
'l Dear Dr. Kaiser.
I This refers to your January 15,1999, response to the Notice of Violation (NOV) transmitted to you by our letter dated October 21,1998, with inspection Report 070-00036/%004(DNMS). In -
your response, you have indicated that Combustion Engineering, Inc., had conducted a root cause analysis of the causes that led to the violation, and also performed a review of dose
- assessments for 1998. ' in addition, you indicated that a meeting with NRC Region ill would be appropriate to discuss the results of these initiatives. Subsequent conversations with members of your staff and Tim Reidinger (Rlll) confirmed that a meeting is scheduled for February 9,
,1999, to discuss your initiatives.
if you have any questions or need further information, please contact Tim Reidinger at (630)-829-9816.
Sincerely,
/s/ Patrick L. Hiland Patrick L. Hiland, Chief Fuel Cycle Branch Docket No. 070-00036 License No. SNM-33 l/
cc:
R. W. Sharkey, Director, Regulatory Affairs
- R. A. Kucera, Director, Missouri Department of Natural Resources
/
)-
(
DOCUMENT NAME: G:\\SEC\\CE98004.RES To receive a cosw or thle document. Indicate in the box:"C" = Copy without enclosure "E"= Copy with enclosure *N"= No copy DFFICE Rlli w]
Rlli l
l l
B4AME Reidinger:ilh G F Hiland CLQ DATE 01/)Y99 01/#,/99 OFFICIAL RECORD COPY
l e
t i
B. Kaiser t i
i bec w/itr dtd 01/15/99:
Docket File PUBLIC IE-07 i
C. Emeigh, NMSS R. Soong, NMSS l
P. Ting, NMSS
- R. Bellamy, RI EJM, Rll (e-mail)
D. B. Spitzberg, RIV/WCFO -
Greens w/o enci i
.t N
l f
i t
I I
i
/
k
$kI$h P%EHF i
Docket No. 70-0036 License No. SNM-33 i
U. S. Nuclear Regulatory Commission ATFN: Document Control Desk Washington, DC 20555
SUBJECT:
AdditionalInformation to Wotice of Violation
Reference:
Letter from Combustion Engineering to NRC dated November 20,1998.
Gentlemen:
Combustion Engineering (CE) committed to provide follow up information to the NRC in Reply to a Notice of Violation concerning NRC Inspection Report No. 70-36/98-004, dated October 21,1998. CE has conducted a root cause analysis of the causes that lead to the violation, and performed a review of dose assessments for 1998. After discussions with Mr. Patrick Hiland and Mr. Tim Reidinger of NRC Region III, CE has determined that the most appropriate way to communicate the results of these initiatives will be to present its results at a meeting with NRC Region 111.
We will be glad to discuss any questions you have concerning our response. If you have any questions or need further information, please contact me at (314) 937-4691.
. Sincerely, s.
COMBUSTION ENGINEERING,INC.
/-/[-77 i
w Robert W. Sharkey llate Director, Regulatory Affairs 1
l cc: Jim Caldwell, Regional Administrator (Acting). NRC Region 111 j
Patrick Hiland, NRC Region III l
l l
l ABB CENO Fuel Operations i
Comt>ustion f.ngineonng. Inc 3300 State Road P leiephone (314) 937-4691 Post Office Don 107 (314) ?96 % 40 gA99g395 Nmustite, tJO 03047 Ias (314) 937-79%
494-bhfos:V& 1p JAN 19 B33