Text

TABLE 3.3-4.

i RADI"TIOS NOWITORISC IN N ATION ili s

C MININUM 1

CHANNELS APPLICABLE ALAaN MEASUREMENT I

INSTRUNENT OPERABLE It00ES SETPOINT RANCE ACTION I

1.

AREA NOEITORS 4

I (a) Spent Fuel Pit Area 1.

Fuel Manipulator 1

(1) 1 5 mR/hr or 2 x 1.0 - 50 mR/hr*

11 background,tehich-ever is% greater (b) Containment 1.

Fuel Manipulator 1

(1) i 10 mR/h or 2 x 1.0 - 1000 mR/hr*

12 background, tshich-m7 over is greater u

I 2.

High Range 1

1.2.3.4 1 5 R/hr 1.0 - 10 R/hr 15 (Also Accident -

Emergency Monitors)

I 2.

PROCESS NOMITORS (a) Containment i

1.

Main Coolant System 1

1.2.3.4 NA 10 - 106 13 ep.

Leakage Air Par-ticulate Monitor di.ac o,e u g=sd 1(2) 1, 2, 3, & 4

.< 6,000 Cpm or 2x 10-IkCPa,or 14 l

.. cenerater Bleudoun Moalters background, whichever 10 - 10 Cpm le greater i -

1 E.

  • Indicated upper end of measurement range is minimum required. Actual measurement range may exceed that i

f, stated.

[

8607090166 860627 8,g g PDR ADOCK 05000029 1