r

In Reply Refer To:

Dockets: 50-498/85-19-01

50-499/85-17-01

Houston Lighting & Power Company

ATTN:

J. H. Goldberg, Group Vice

President

P. O. Box 1700

Houston, Texas 77001

Dear Mr. Goldberg:

Thank you for your letter of April 7,1986, in response to our letter dated

March 7, 1986, requesting supplemental information relative to Notice of

Violation 85-19-01/85-17-01. We have received your reply and find it

responsive to our request for supplemental information.

We will review the implementation of your corrective actions during a future

inspection to determine that full compliance has been achieved and will be

maintained.

Sincerely,

original signed b)st

J. E. GAGLIARDO"

J. E. Gagliardo, Chief

Reactor Projects Branch

cc:

Houston Lighting & Power Company

ATTN:

M. Wisenberg, Manager,

Nuclear Licensing

P. O. Box 1700

Houston, Texas

77001

Brian Berwick, Esquire

Asst. Attorney General

Environmental Protection Div.

P. O. Box 12548, Capitol Station

Austin, Texas 78711

8607080305 860624

PDR

ADOCK 05000493

jgo/

\\

0

PDR

r

,

i

Lanny Alan Sinkin

Citizens Concerned About

Nuclear Power, Inc.

Christic Institute

1324 North Capitol Street

Washington, DC

20002

Charles Bechhoefer, Esquire

Chairman, Atomic Safety & Licensing

Board

U.S. Nuclear Regulatory Commission

Washington, DC

20555

Dr. James C. Lamb, III

313 Woodhaven Road

Chapel Hill, North Carolina

27514

Frederick J. Shon

Administrative Law Judge

Atomic Safety and Licensing Board

U.S. Nuclear Regulatory Commission

Washington, DC

20555

Ray Goldstein, Esquire

Gray, Allison and Becker

100 Vaughn Building

807 Brazos

Austin, Texas

78701

Alvin H. Gutterman

Newman & Holtzinger, P.C.

1615 L St., N.W., Suite 1000

Washington, DC

20036

Texas Radiation Control Program Director

bcc to DMB (IE01)

bec distrib. by RIV:

RPB

DRSP

Resident Inspector-0PS

R. D. Martin, RA

Resident Inspector-CONST.

  • SectionChief(RPB/C)

MIS SYSTEM

RIV File

  • D. Weiss,LFMB(AR-2015)

RSTS Operator

R. Pirfo, ELD

R. G. Taylor, RPB/C

RPB f8

RP

RPB

I/

BBreslau:cnm

LE,onstable

JEGag1I hrdo

6/.://86

6hyB6

6/sT8y

/ N!

. .

.

.

The Light

.

NE

Uf Houston Lighting & Power P.O. Box 1700 Houston, Texas 77001 (713)228-9211

April 7, 1986

ST-BL-AE-1642

File No.: C2.4

n [i!@ G! DM F ~ l

Mr. Robert D. Martin

I) '

'

'l

Regional Administrator, Region IV

$

U. S. Nuclear Regulatory Commission

APR I 01 % (,i)

611 Ryan Plaza Drive Suite 1000

lu

Arlington, Texas 76011

'

South Texas Project

Units 1 & 2

Docket Nos. STN 50-498, STN 50-499

Request for Supplemental Information

Concernina Notice of Vlointfon 8519-01/8517-01

Dear Mr. Martin

The following information is submitted in response to your request dated

March 7,1986 relative to Notice of Violation 85-19-01/85-17-01.

In October,1985, HL&P was informed by the NRC Resident Inspector of a

documentation concern relative to pipe support packages for the Essential

Cooling Water System. Specifically, certain packages which had been QC

accepted did not contain the filler material reference number as required by

the procedure in effect at the time of the NRC review . HI4P Quality

Assurance performed an investigation based on this concern and confirmed that

a number of packages were indeed missing this information. This deficiency

was documented in Standard Deficiency Report, SDR fH-194.

l

In preparing our response to the Notice of Violation, it was determined

that all support packages refe' renced by the HL&P SDR and the Notice of

Violation as missing filler material reference number were prepared during a

time when the site procedure (SSP-18) did not require the listing of the

filler material reference number. The change document that deleted the

requirement was subsequently volded and therefore never incorporated into the

current procedure that was provided to the NRC inspector during his

,

j

investigation. The SDR generated as a result of the QA investigation was in

j

error.

i

l

y (o o 5 16o9W

e

'L4/NRC/c

s c-oG3 %

e

_

__

_

_

_

.

.

. _.

. _ _ -

-

-

._

-

.

,

ST-HL-AE-1642

Filo No.: C2.4

,

liouston 1.ighting & Power Company

Page 2

The current revision of site proecedure (SSP-18) does not require listing

of filler material reference numbers for ASME Class II or III supports. This

information is not required by the ASME Code.

If you have any additional questions please contact Scott M. Head at

512-972-8392.

Very truly yours.

.

J. H. Goldberg

Group Vice President, Nuclear

SMH/ag

l

i

L4/NRC/c

.-__ _

_

- _ _ .

.

. - - - _ _ _ _ _ _ - _ . - .

_ _ _ _ - _ _ - . -

_ _ _

..

_ _ - . . - _ _ _

-

"

.

ST-HL-AE-1642

, -

Pilo No.: C2.4

4

Houston Lighting & Power Company

Page 3

,

cc

Hugh L. Thompson, Jr., Director

Brian E. Berwick, Esquire

Division of PWR Licensing - A

Assistant Attorney General for

Office of Nuclear Reactor Regulation

the State of Texas

U.S. Nuclear Regulatory Commission

P.O. Box 12548, Capitol Station

Washington, DC 20555

Austin, TX 78711

N. Prasad Kadambi, Project Manager

Lanny A. Sinkin

U.S. Nuclear Regulatory Commission

C%istic Institute

7920 Norfolk Avenus

1324 North Capitol Street

Bethesda, MD 20814

Washington, DC 20002

Claude E. Johnson

Oreste R. Pirfo. Esquire

Senior Resident Inspector /STP

Hearing Attorney

c/o U.S. Nuclear Regulatory

Office of the Executive Legal Director

Commission

U.S. Nuclear Regulatory Comunission

P.O. Box 910

Washington, DC 20555

Bay City, 11 77414

Charles Bechhoefer, Esquire

M.D. Schwars, Jr., Esquire

Chairman, Atomic Safety &

Baker & Botts

Licensing Board

One Shell Plaza

U.S. Nuclear Regulatory Commission

Houston, TX 77002

Washington, DC 20555

J.R. Newman, Esquire

Dr. James C. Lamb, III

Newman & Holtsinger, P.C.

313 Woodhaven Road

1615 L Street, N.W.

Chapel Hill, NC 27514

Washington, DC 20036

Judge Prederick J. Shon

Director Office of Inspection

Atomic Safety and ilconsing Board

and Enforcement

U.S. Nuclear Regulatory Commission

U.S. Nuclear Regulatory Commission

Washington, DC 20555

Washington, DC 20555

Mr. Ray Goldsteln. Esquire

T.V. Shockley/R.L. Range

1001 Yaughn Buf1 ding

Central Power & Light Company

807 Brasos

P.O. Box 2121

Austin, TX 78701

Corpus Christi, TK 78403

Citizens for Equitable Utilities Inc.

H.L. Peterson/G. Pokorny

c/o Ms. Peggy Buchorn

City of Austin

Route 1 Box 1684

P.O. Box 1088

Brasoria, TX 77422

Austin, TX 78767

Docketing & Service Section

J.B. Poston/A. vonRosenberg

Office of the Secretary

City Public Service Board

U.S. Nuclear Regulatory Commission

P.O. Box 1771

Washington, DC 20555

San Antonio, TK' 78296

(3 Copies)

Advisory Commaittee on Reactor Safeguards

U.S. Nuclear Regulatory Commission

1717 H Street

Washington, DC 20555

Revised 12/2/85

L4/NRC/c

-