o SEABROOK STATION Engin:ering Office

--e NEW HAMPSHIRE YANKEE DIVISION June 20, 1986 SBN-1126 T.F.

B7.1.2 United States Nuclear Regulatory Commission Washington, DC 20555 Attention:

Mr. Vincent S. Noonan, Project Director 3

PWR Project Directorate No. 5

References:

(a) Construction Permits CPPR-135 and CPPR-136, Docket Nos. 50-443 and 50-444 (b) PSNH Letter (SBN-998), dated April 10, 1986,

" Response to Environmental Qualification Audit Observation", J. DeVincentis -to V. S. Noonan Subj ect:

IE Information Notice 86-02

Dear Sir:

In Reference (b) we advised that the NSSS supplied Limitorque actuators were being reviewed. The purpose of this letter is to document the result of our review which was previously discussed with the Staff.

Magnesium rotors are used on Reliance Motors of frame sizes 180 and above for Limitorque operators.

Westinghouse has confirmed, through a technical audit at Limitorque that a motor, with a magnesium rotor, has been tested to the Westinghouse qualification temperature peaks of 420*F referenced in EQDP-HE-1.

The tested motor, with a magnesium rotor has a HELB profile identical to EQDP-HE-1.

62h88hh0443 PDR CW 86 G

0 I O Seabrook Station Construction Field Office. P.O. Box 700 Seabrook, NH O3874

i United States Nuclear Regulatory Commission Attention:

Mr. Vincent S. Noonan Page 2 i

i Seabrook has qualified the Westinghouse NSSS supplied Limitorque actuators inside containment by utilizing the same test report. There-fore, we consider the Seabrook NSSS supplied Limitorque actuators with magnesium rotors qualified.

As stated in Reference (b), no magnesium rotors were supplied as part of BOP supplied Limitorque actuators.

4 In conclusion, we have determined that all Limitorque actuators are qualified for the harsh environments that could occur under postu-

[

lated accident environments.

Very truly yours, j

John DeVincentis Director of Engineering cc: Atomic Safety and Licensing Board Service List i

i I

i 1

i i

I 1

e

Diens Curran, Esquire Pater J. Mathswa, Mayor Hermon & Weico City Ht11 2001 S. Street, N.W.

Nawburyport, MA 01950 Suite 430 Washington, D.C.

20009 Judith H. Mizner Silvergate, Gertner, Baker, Sherwin E. Turk, Esq.

Fine, Good & Mizner Office of the Executive Legal Director 88 Broad Street U.S. Nuclear Regulatory Commission Boston, MA 02110 Tenth Floor Washington, DC 20555 Calvin A. Canney City Manager Robert A. Backus, Esquire City Hall 116 Lowell Street 126 Daniel Street P.O. Box 516 Portsmouth, NH 03801 Manchester, NH 03105 Stephen E. Merrill, Esquire Philip Ahrens, Esquire Attorney General Assistant Attorney General George Dana Bisbee, Esquire Department of The Attorney General Assistant Attorney General Statehouse Station #6 Office of the Attorney General Augusta, ME 04333 25 Capitol Street Concord, NH 03301-6397 Mrs. Sandra Gavutis Chairman, Board of Selectmen Mr. J. P. Nadeau i

RFD 1 - Box 1154 Selectmen's Office Kenosington, NH 03827 10 Central Road Rye, NH 03870 Carol S. Sneider, Esquire Assistant Attorney General Mr. Angie Machiros Department of the Attorney General Chairman of the Board of Selectmen One Ashburton Place, 19th Floor Town of Newbury Boston, MA 02108 Newbury, MA 01950 Senator Gordon J. Humphrey Mr. William S. Lord U.S. Senate Board of Selectmen Washington, DC 20510 Town Hall - Friend Street (ATIN: Tom Burack)

Amesbury, MA 01913 Richard A. Hampe, Eaq.

Senator Gordon J. Humphrey j

Hampe and McNicholas 1 Pillsbury Street i

35 Pleasant Street Concord, NH 03301 l

Concord, NH 03301 (ATTN: Herb Boynton)

Thomas F. Powers, III H. Joseph Flynn, Esquire Town Manager Office of General Counsel l

Town of Exeter Federal Emergency Management Agency 10 Front Street 500 C Street, SW Exeter, NH 03833 Washington, DC 20472 i

Erentwood Board of Selectmen Paul McEachern, Esquire RFD Dalton Road Matthew T. Brock, Esquire Brentwood, NH 03833 Shaines & McEachern 25 Maplewood Avenue Gary W. Holmes, Esq.

P.O. Box 360 Holmes & Ells Portsmouth, NH 03801 i

47 Winnacunnet Road Hampton, NH 03842 Robert Carrigg Town Office Mr. Ed Thomas Atlantic Avenue FEMA Region I North Hampton, NH 03862 442 John W. McCormack PO & Courthouse Boston, MA 02109 l

1

D O

to Administrative Judge Helen Hoyt, Chairperson Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Administrative Judge Sheldon J. Wolfe, Chairman Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Dr. Eameth A. Luebke Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Dr. Jerry Harbour Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, D.C. 20555 0

i e...