ML20199F314

From kanterella
Jump to navigation Jump to search
Ack Receipt of Ltr Dtd 980924,transmitting Changes (Rev 33) to Plant Modified Amended Security Plan Per Provisions of 10CFR50.54(p).Issue During Limited Review Noted & Requires Clarification.Review Comments Encl
ML20199F314
Person / Time
Site: Cook  
Issue date: 01/13/1999
From: Creed J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Powers R
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
References
NUDOCS 9901210284
Download: ML20199F314 (3)


Text

-

WEXS L

!lp January 13, 1999 Mr. Rotert P. Powers Vice President l

Indiana Michigan Power Company l

500 Circle Drive l

Buchanan, MI 49107 l

l

SUBJECT:

PHYSICAL SECURITY PLAN CHANGES l

l

Dear Mr. Powers:

l This letter acknowledges receipt of your letter dated September 24,1998, which transmitted i

changes (Revision 33) to the Donald C. Cook Modified Amended Security Plan submitted under the provisions of 10 CFR 50.54(p).

l Based on your determination that the changes do not decrease the effectiveness of your security plan, and after limited review of the changes, no NRC approval is required, in accordance with 50.54(p). One issue noted during the limited review appears to require l

clarification and is addressed in the enclosure to this letter. The changes in Revision 33 of the security plan will be subject to inspection to confirm that the changes have not decreased the l

effectiveness of the plan.

l [N The enclosure to your letter concerns a subject matter which is exempt from public disclosure l

in accordance with 10 CFR 73.21 and is therefore being withheld from public disclosure. In l

accordance with 10 CFR 2.790 of the Commission's regulations, a copy of this letter will be placed in the NRC Public Document Room.

Sincerely, de**

t mes. Creed, Chie lant Support Branch 1 l

Docket Nos.: 50-315;50-316 License Nos.: DPR-58; DPR-74

Enclosure:

As stated l

See Attached List

" 13 t

bec:

NRR/DRPM/PSGB I

NRR Docket File l

SG Case File No. W7048646WA; W7048747WA jj SG Inspector File: Plan DOCUMENT NAME: G:DRS\\DCC010}9.WPD v.

e..... cow or thi. e euin.nuascate en th. tier c em m.m ch,neauvio.u<. r em -m.nch-.au. e.o<. v = No em

/^\\

OFFICE Rlll f, l6 Ipi / /

ld l

l m

'b NAME Beladgerjp Ch g DATE 01/fi/99 OW 99 r

OFFICIAL RECORD COPY 9901210284 990113 PDR ADOCK 050003 5 ggj

p ENCLOSURE REVIEW COMMENTS FOR REVISION 33 OF THE D.C. COOK SECURITY PLAN Chapter Section Comment 4

4.1.2.1 The adjective, "approximately"is too vague to be meaningful.

This revision added the adjective "approximately" in reference to the height of the protected area barrier, i.e. fencing and gates are "approximately" seven feet high topped by a 12-inch high barbed wire section....to make the overall barrier height "approximately" eight feet from ground level. You need to specify what deviation is acceptable while still maintaining the effective height of the barrier.

O r(

1

\\

~-. _ -.. - - - _ ~

p Mr. ' Robert P. Powers Donald C. Cook Nuclear Plant

. American Electric Power Company cc:

Attomey General Mr. S. Brewer Department of Attorney General Indiana Michigan Power 525 West Ottawa Street Nuclear Generation Group Lansing, Michigan 48913 500 Circle Drive Buchanan, MI 49107 Township Supervisor Lake Township Hall David A. Lochbaum I

P.O. Box 818 Union of Concerned Scientists Bridgman, Michigan 49106 1616 P Street, N.W., Suite 310 Washington, DC 20036-1495 R. Eckstein, Chief Nuclear Engineer American Electric Power Company Cook Nuclear Plant One Cook Place Bridgman, MI 48909 U.S. Nuclear Regulatory Commission Resident inspector's Office 7700 Red Arrow Highway p

Stevensville, Michigan 49127 Gerald Chamoff, Esquire Shaw, Pittman, Potts and Trowbridge 2300 N Street, N. W.

Washington, DC 20037 Mayor, City of Bridgman Post Office Box 366 Bridgman, Michigan 49106 Special Assistant to the Governor Room 1 - State Capitol Lansing, Michigan 48909 Michigan Dept. of Environmental Quality Drinking Water & Radiological Protection Division Radiological Protection Section Nuclear Facilities Unit 3423 N. Martin Luther King, Jr. Blvd.

l P. O. Box 30630 CPH Mailroom l

Lansing, Michigan 48909-8130 h

V

{

,