SEMIANNUAL RADI0 ACTIVE EFFLUENT RELEASE REPORT ADDEN0tM FACILITY:

River Bend Station,- Unit 1 LICENSEE:

Gulf States Utilities Company REPORT PERIOD:

October 31, 1985 through December 31, 1985 This addendum is submitted under River Bend Station (RBS) License Number NPF-47 and provides information that was not yet available while the Quarter 3/4 1985 RBS Semiannual Radioactive Effluent Release Report was being compiled.

Specifically, this addendum provides information on Sr-89 and 5 -90 Gaseous Effluent Releases (pages 19 and 22 of original report); and Sr-89, Sr-90 and Fe-55 Liquid Effluent Releases (page 26 of original report) obtained from vendor-performed analyses of quarterly composite samples.

It should be noted that an entry of "0.00E + 00" Ci in the following tables does not indicate the absence of a radionuclide; but, rather, indicates that the concentration of the particular radionuclide was below the Lower Limit of Detection (LLD).

SBS62;ggggt88gge l

R

TABLE 4 ADDENDtM Effluent and Waste Disposal Semi-Annual Report 1985 Year Gaseous Effluents - Conditionally Elevated Releases 3/4 Quarters l

Continuous Mode Batch Mode Nuclides Released l Unit l Quarter 3 l

Quarter 4 l Quarter 3 l Quarter 4 3.

Particulates Strontium-89 l

Ci l

N/A l 0.00E + 00(2) l N/A l 0.00E + 00(2)

Strontium-90 Ci l

N/A l 0.00E + 00(2) l N/A l 0.00E + 00(2) l (2)

Quarterly composite particulate filter analysis indicates a Minimum Detectable Activity (MDA) concentration of <1E-15 uCi/cc for the Main Plant Exhaust Duct. This value is less than the Lower Limit of Detection (LLD) of 1 x 10~I1 uCi/ml as specified in Table 4.11.2.1.2-1 of RBS Technical Specifications.

1 i

y

.,,._.,e

TABLE 5 ADDENDUM Effluent and Waste Disposal Semi-Annual Report 1985 Year Gaseous Effluents - Ground Level Releases 3/4 Quarters Continuous Mode Batch Mode I

Nuclides Released l Unit l Quarter 3 l Quarter 4 l Quarter 3 l Quarter 4 1

3.

Particulates ll) l N/A l 0.00E + 00(1) i Strontium-89 l

Ci l

N/A l 0.00E + 00 Strontium-90 l

Ci l

N/A l 0.00E + 00(1) l N/A l 0.00E + 00(1) i (1)

Quarterly composite particulate filter analysis indicates a Minimum Detectable Activity (MDA) concentration of <1E-15 uCi/cc for both the Fuel Building Exhaust Vent and the Radwaste Building Exhaust Vent.

This value is less than the Lower Limit of Detection (LLD) of 1 x 10~11 uCl/ml as specified in Table 4.11.2.1.2-1 of RBS Technical Specifications.

e

TABLE 6 ADDE 110LM Effluent and Waste Disposal Semi-Annu,al Report 1985 Year G.

Liquid Effluents 3/4 Quarters Continuous Mode Batch Mode J

Nuclides Released i Unit ! Quarter 3 l Quarter 4 l Quarter 3 l Quarter 4 Strontium-89 l

Ci l

N/A l

N/A l

N/A

! 0.00E + 00(1)

Il}

Strontium-90 l

Ci N/A l

N/A l

N/A l 0.00E + 00 Iron-55 l

Ci l

N/A l

N/A l

N/A l0.00E+00(2}

(1)

Analysis of quarterly composite indicates a Minimum Detectable Activity (MDA) concentration of <1E-09 uCi/cc. This value is less than the Lower Limit of Detection (LLD) of 5 x 10-8 uCi/ml t

as specified in Table 4.11.1.1.1-1 of RBS Technical Specifications.

l

)

(2)

Analysis of quarterly composite indicates a Minimum Detectable Activity (MDA) concentration of <4E-07 uCi/cc. This value is less than the Lower Limit of Detection (LLD) of 1 x 10-6 uCi/ml as specified in Table 4.11.1.1.1-1 of RBS Technical Specifications.

i i