purov UNITED STATES s

g NUCLEAR REGULATORY COMMISSION 2

WASHINGTON, D.c. 2066H001 SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION RELATED TO AMENDMENT NO.164TO FACILITY OPERATING LICENSE NO. DPR-28 VERMONT YANKEE NUCLEAR POWER CORPORATION VERMONT YANKEE NUCLEAR POWER STATION DOCKET NO. 50-271

1.0 INTRODUCTION

The Vermont Yankee Nuclear Power Station is a boiling water reactor (BWR), model BWR-4, with a Mark I containment. By letter dated November 3,1998, as supplemented by letter dated December 15,1998, the Vermont Yankee Nuclear Power Corporation, the licensee for the Vermont Yankee Nuclear Power Station, submitted for Nuclear Regulatory Commission (NRC) staff review a proposed change to the technical specifications (TS). The licensee proposed a number of minor corrections or clarifications which enhance the clarity of the Technical Specifications without materially changing meaning or application. The changes include corrections of typographical errors, administrative errors, and addition of component identification numbers to improve specificity and consistency. Enclosed is a table provided by the licensee describing the changes. The December 15,1998, supplement did not change the original no significant hazards conclusion.

2.0 EVALUATION 2.1 Specification of Component identification Numbers Many of the changes involved the specification of component identification numbers in TS including TS associated with surveillance requirements. The licensee provided the following as a basis for this change: This change achieves consistency with other TSs where component identification numbers are already included. Also, this avoids confusion and the potential for errors. Instrument tag numbers are indicative of the device providing the required TS function and are not inclusive of all components in the associated instrument channel. This is consistent with the methodology previously used to define instrument channels providing a TS function.

Other documents define all required components within a TS instrument channel.

TSs define " Operable" as "A system, subsystem, train, component or device shall be operable or have operability when it is capable of performing its specified function (s). Implicit in this definition shall be the assumption that all necessary attendant instrumentation, controls, normal and emergency electrical power sources, cooling or seal water, lubrication or other auxiliary equipment that are required for the system, subsystem, train, component or device to perform its function (s) are also capable of performing their related support function (s)." The addition of component identification numbers does not alleviate the requirement of the licensee to consider the unlisted components to determine operability of all TS components. Therefore, the staff considers the proposed changes acceptable.

9901200421 990105 PDR ADOCK 05000271 P

PDR

P l

l l

2-l 2.2 Other Changes including Typographical and Administrative Corrections The licensee proposed to change TS T3.13.A.1 to indicate that the switchgear room actually consists of two fire areas, switchgear room east and switchgear room west, and 10 smoke sensors per area are required vs 20 for the two areas. This change was approved by TS Amendment 154 on March 6,1998; however, the licensee omitted updating this table as a part

~

l of the previous amendment request. The staff finds that this change is acceptable as it is consistent with the NRC safety evaluation dated March 6,1998, associated with TS Amendment 154.

The licensee proposed to correct the chloride ion concentration from 0.01 ppm to 0.1 ppm in TS l

3.6.B.2 for reactor coolant water. The licensee stated that this corrects a typographical error made during ;cformatting in 1994 and that the value should have remained 0.1 ppm as stated in the original TS and Amendment 91, the latest amendment to the TS page containing this value. The staff confirmed that the value specified by Amendment 91 issued on October 28, 1985, the current amendment number for this page, specified a chloride ion concentration of 0.1 ppm and the value was inadvertently changed during reformatting. The proposed change is therefore acceptable.

Numerous other minor changes were proposed such as changing " accident of abnormal" to l

accident or abnormal" on TS page 35. The staff has reviewed the proposed changes and has concluded that the changes improve the TS but do not change the meaning of the TS. The proposed changes are therefore acceptable.

3.0 STATE CONSULTATION

in accordance with the Commission's regulations, the Vermont State official was notified of the proposed issuance of the amendment. The State official had no comments.

4.0 ENVIRONMENTAL CONSIDERATION

The amendment changes a requirement with respect to installation or use of a facility component located within the restricted area as defined in 10 CFR Part 20 and changes 1

surveillance requirements. The NRC staff has determined that the amendment involves no significant increase in the amounts, and no significant change in the types of any effluents that may be released offsite, and that there is no significant increase in individual or cumulative occupational radiation exposure. The Commission has previously issued a proposed finding that the amendment involves no significant hazards consideration, and there has been no public comment on such finding (63 FR 66605). Accordingly, the amendment meets the l

eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(c)(9). Pursuant to 10 CFR l

51.22(b), no environmental impact statement or environmental assessment need be prepared in connection with the issuance of the amendment.

4 J

4 r

5.0 CONCLUSION

The Commission has concluded, based on the considerations discussed Lbove, that: (1) there is reasonable assurance that the health and safety of the public will not be endangered by operation in the proposed manner, (2) such activities will be conducted in compliance with the Commission's regulations, and (3) the issuance of the amendment will not be inimical to the common defense and security or to the health and safety of the public.

Principal Contributor: Richard Croteau Date: January 5, 1999

Attadinseat A ta BVY 98-118 Vermont Ycnkee Nuclear Power Station Technical Specificatior.s Proposed Change No. 205 Desenphon and Bases for Changes Paoe 1 of 9 No.

Page Section Description and Basis for Chango l

Change: Add sections 3.2.J. 3.2.K, and 3.2.L to the Table of Contents i

I 1

ii TOC Corrects an error in the Table of Contents by adding sectons of the Technical Specificatiens not currently e

included in the Table of Contents. This achieves consistency by having all major sechons of the Technical t

Specifications listed in the Table of Contents Change "available" to " availability

  • 2 17 B2.1.H Corrects a typographical error j

Change "operbdity* to "operabdity' 3

20 3.1 Corrects a typographical error i

Change "instrumenttion" to " instrumentation

  • l 4

20 4.1 Corrects a typographical error Change. Add component identification numbers 5

21 T3.1.1 Changes nomenclature by designating component identification numbers of associated instrumentation with trip functons. This achieves consistency with other Technical SpediwGuns where component identification L

numbers are already included An additional benefit to including component numbers in the Technical Specifications is the avoidance of confusion and the potential for errors Note for all changes within Proposed Change-205 involving instrument tag numbers: Instrument tag numbers are indicative of the device (instrument) providing the required funcbon and are not inclusive of all cciTiponents i

in the associated instrument channel. This is consistent with the methodology previously used to define instrument channels providing a Technical Specifications functon Other controlled documents provide e

definition of all required ccTpanents within a Technical SpedTOGuns instrument channel.

In one of the column headings, change " Min. No." to " Minimum Number' 6

22 T3.1.1 Achieves consistency in the Technical Specifications, speciGcally with the same column heading on page 21.

Change: Add component identification numbers 7

22 T3.1.1 Changes nomenclature by designating component identification numbers of associated instrumentation with i

e trip functions. This achieves consistency with other Technical Specificatens where component identificaten numbers are already included An additional benefit to including component numbers in the Technical.

i Specifications is the avoidance of confusion and the potential for errors Change: Add Table title to page 8

22 T3.1.1 Achieves consistency in the Technical Specificabons by having Table titles at the top of pages Change " lead" to " load

  • in Note 3.c.

9 23 T3.1.1 Notes Conects a typsy.pinical error l

m 5:

E l

A ovv,

1 1

Attachment A t3 BVY 98-118 Vermont Yankee Nuclear Power Station Technical Spc,,irications Proposed Change No. 205 Description and Bases for Changes Paae 2 of 9 No.

Page Section Description and Basis for Change Change: Add component identification numbers 10 25 T4.1.1 Changes nomenclature by designating component identification numbers of associated instrumentation with trip functions. This achieves consistency with other Technical Specifications where wic.f,v.ent identification numbers are already included Component identification numbers are not repeated if the component was identified by number in the corresponding LCO table. An additional benefit to including component numbers in the Technical Specifications is the avoidance of confusson and the potential for errors 11 27 T4.1.2 Change Add component identification numbers Changes nomenclature by designating component identification numbers of assocsated instrumentation with trip funchons. This achieves consistency with other Technical Specifications where component identification numbers are already included An edditional benefit to including component numbers in the Technical Specifications is the avoidance of confusion and the potential for errors Change "on FSAR Page 7.5-8* to *in FSAR Sechon 7.5.5.4* in last line of the 6" pari.wi.pi.

12 29 B3.1 Corrects an error and provides consistency within the Technical Specificabons' Bases by i, J..= icing FSAR sections instead of page numbers Change

  • Instrumentation (pressure switches) is..." to
  • Instrumentation is...* in the first line of the last 13 29 B3.1 paragraph Corrects an error (the desenpbon was not inclusive of all sensors provided for this function)

Change *bi-stable" to " bistable" 14 33 B4.1.A e

Corrects a type i piical error and achieves consistency in the Technical Specifications v

Change "3.5 the* to *3.5, the" in the 4" line 15 34 3.2.A Corrects a typ0giapiiical error Change " accident of abnormal

  • to
  • accident or abnormal" in the 9" line 16 35 3.2.G Corrects a typa i piical error v

Change " operative

  • in the 4" line 17 36 3.2.1 Corrects a typographical error and/or achieves consistent, defined terminology in the Technical Specifications Change " operative" to
  • in the 4" line 18 36 3.2.K Corrects a typographical error and achieves consistent, defined terminology in the Technical Spec;Ticot;uns 19 38 T3.2.1 Change: Capitalize each word in heading of last column from *... Conditions for Operabon are Not Satsfied* to

... Conditions For Operation Are Not Satisfied

  • Achieves consistency within the Technical Specifications 20 38 T3.2.1 Change: Add component identification numbers Changes nomenclature by designating component idenbfication numbers of associated instrumentation with i

trip funcbons. This achieves consistency with other Technical Specifications where component identification numbers are already included An additional benefit to including winpunwat numbers in the Technical l

Specifications is the avoidance of confusion and the potential for errors i

BVY96119A; ociotier 30.1998 r

x..

}

- Attachment A to BVY 98-118 l

  • ,-[

Vermont Ytnkee Nuclear Power Station Technical Spedricariens Proposed Chat;ge No. 205 l

Description and Bases for Changes Paae 3 of 9 No.

Page Section Description and Basis for Change Change: Capitalize each word in heading of last column from *.. Conditions for Opei.iivn are Not Satisfied

  • to 21 39 T3.2.1

.. Conditions For Operation Are Not Satisfied" Achieves consistency within the Technical Specifications Change: Add ce6.penent identification numbers 22 39 T3.2.1 Changes nomenclature by designating component identification numbers of assocated instrumentation with trip functions. This achieves consistency with other Technical Specifications where component identification f

numbers are already included An additional benefit to including component numbers in the Technical Specifications is the avoidance of confusion and the potential for errors Change trip function *RHP. Pump A & C Discharge Pressure" to "RHR Pump (A-D) Disi.t

v. Pressure" l

23 39 T3.2.1 This change wiiocts an error in the existing Technical Specificatons in that only two of the four RHR pumps are listed. This trip funchon is applicable to all four RHR pumps, not just A & C.

Change: Capitalize each word in heading of last column from *... Conditions for Cpo..i;un are Not Satisfied

  • to 24 40 T3.2.1 i

... Conditions For Operation Are Not Satisfied

  • Achieves consistency within the Technical Specifications Change: Add component identification numbers 25 40 T3.2.1 Changes nomenclature by designating component identification numbers of associated instrumentation with trip functions. This achieves consistency with other Technical Specifications where component identification l

L numbers are already included An additional benefit to including component numbers in the Technical Specifications is the avoidance of confusion and the potential for errors l

Change: Capitalize each word in heading of last column from *... Conditions for Cpoi.i.un are Not Satisfied" to

[

26' 41 T3.2.1

... Conditions For Operation Are Not Satisfied" l

Achieves consistency within the Technical Specifications i

Change: Add component identification numbers 27 41 T3.2.1 Changes nomenclature by designating component identificahon numbers of associated instrumentation with

[

trip functions. This achieves consistency with other Technical Specifications where component identificebon numbers are already included. An additional benefit to including component numbers in the Technical Specifications is the avoidance of confusion and the potential for errors r

Change: Capitalize each word in heading of last column from "... Conditions for Operation are Not Satisfied" to 28 42 T3.2.1

,.. Conditions For Operation Are Not Satisfied

  • Achieves consistency within the Technical SpedTm.i.uns Change: Add component identification numbers and reformat the component identification number of the third

[

29 42 T3.2.1 item (i.e.. Time Delay) listed under " Trip Function" from *2E-KSA and B" to *2E-KSA/B" l

Changes nomenclature by designating component identification numbers of assocated instrumentation with j

trip functions. This additional nomenclature and change in format achieve consistency with other Technical Specifications where component identification numbers are already included. An additional benefit to including

[

component nurnbers in the Technical SpedTr +tions is the avoidance of confusion and the potential for errors t

i BVY98118A; october 30.1998 i

4 Attachment A to BVY 98-118 Vermont Yankee Nuclear Power Station Technical Specifications Proposed Change No. 205 Description and Bases for Changes Paae 4 of 9 i

No.

Page Section Descrt,,66 and Basis for Chenge Change: Capitalize each wvid in heading of last column fiuni... Conditions for Cimi. tion are not Satisfied" to 30 43 T3.2.1

.. Conditions For Operation Are Not Satisfied

  • Achieves consistency within the Technical Specifications Change: Add component identification numbers 31 43 T3.2.1 Changes nomenclature by designating winpcsient identificahon numbers of associated instrumentation with trip functions. This achieves consistency with other Technical SpeciTn,.' vns where component identification o

numbers are already included An additional benefit to including component numbers in the Technical Specifications is the avoidance of confusion and the potential for errors Change "one-out-of two" to *one-out-of-two" in Note 4 32 44 T3.2.1 Notes Corrects a typographical error and achieves consistency in the Technical Specifications Change: Capitalize each word in heading of last column Ticin *... Conditions for Operation are Not Satisfied

  • to 33 45 T3.2.2

..Condit.ons For Operation Are Not Satisfied" Achieves consistency within the Technical Spec;Tn T,ns Change: Add component identification nuiTibeis 34 45 T3.2.2 Changes nomenclature by designating coinpunent identification numbers of associated instrumentation with trip functions. This achieves consistency with other Technical Spedin,.tions where component identification numbers are already included. An additional benefit to including component numbers in the Technical Specifications is the avoidance of confusion and the potential for errors Change: Capitaiize each word in heading of last column fivni"... Conditions for Opeistion are not Satisfied

  • to 35 46 T3.2.2

.. Conditions For Operation Are Not Satisfied" Achieves consistency within the Technical Specifications Change: Add component identification nuiTibers 36 46 T3.2.2 Changes nomenclature by designating component identification numbers of associated instrumentation with trip functions. This achieves consistency with other Technical Specifications where component identifiution nunebers are already included. An additional benefit to including component numbers in the Technical Specifications is the avoidance of confusion and the potential for errors Change: Capitalize each word in heading of last column from "... Conditions for Operation are not Satisfied

  • to 37 47 T3.2.2

... Conditions For Operation Are Not Satisfied" Achieves consistency within the Technical Specifications Change: Add component identification numbers 38 47 T3.2.2 Chat.ges nomenclature by designating cuivipcsient identification numbers of associated instrumentation with trip functions. This achieves consistency with other Technical Specificabons where component identification numbers are already included An additional benefit to including component numbers in the Technical Specifications is the avoidance of confusion and the potenhal for errors BVY98118A; october 30.1998

Attachment A to BVY 98-118 Vermont Yankee Nuclerr Power Station Technical Specifications Proposed Change No. 205 l

Descriphon and Bases for Changes Pace 5 of 9 i

l No. EP de Section Description and Basis for Change Change the heading of last column from "... Conditions for Operation are not Met" to "... Conditions For 39 49 T3.2.3 Operation Are Not Satisfied" Corrects the heading to achieve consistency within the Technical Spedistions 70 49 T3.2.3 Change: Add component identification numbers Changes nomenclature by designating component identification numbers of associated instrumentation with e

trip functions. This achieves consistency with other Technical Specifications where component identification I'

numbers are already included. An additional benefit to including cuinpcasnt numbers in the Technical Specifications is the avoidance of confusion and the potential for errors Change the heading of last column from "... Condition for Operation are Not Mer to "... Conditions For 41 50 T3.2.4 Operation Are Not Satisfied" Corrects the heading to achieve consistency within the Technical Spedricauens i

Change: Add component identification numbers 42 51 T3.2.5 Changes nomenclature by designating component identification numbers of associated instrumentation with i

trip functions. This achieves consistency with other Technical Spedricauens where component identification numbers are already included. An additional benefit to including wniy06ent numbers in the Technical i

Specifications is the avoidance of confusion and the potential for errors t

Change component identification numbers and add further designation of wnsponents 43 53 T3.2.6 Changes component identification to add additional designation or clanfy designatica. In two cases, designation of temperature elements (TE) was deleted since this provided superfluous information. By adding and clarifying cuinpenent designation thee changes represent nomenclature changes and achieve consistency with other Technical Specifications where component identificahon numbers are already included.

i An additional benefit to including component numbers in the Technical SpedTwiions is the avoidance of confusion and the potential for errors Change containment hydrogen / oxygen " meter" to "reccids" in two places 44 54 T3.2.6 Corrects an error by providing the proper terminology for these components Change: Add and correct component identification numbers 45 54 T3.2.6 Changes nomenclature by designating wi6penent identification numbers of associated instrumentation with trip functions. This achieves consistency with other Technical Specifications where component identification L

numbers are already included An additional benefit to including component numbers in the Technical Specifications is the avoidance of confusion and the potential for errors Corrects an error in that the first item listed under " Type of Indicabon* should be changed from " Meter Z1-2-1 A/B" to

  • Meter ZI-2-1 A/B" 46 SSE T3.2.7 Change: Inserts a new page For consistency and clarity within the Technical Spedricdions, this chares notes that Table 3.2.7 was e

intentionally deleted.

i

[

BVY98118A; october 30,1998 1

I

Attach aent A ts BVY 98-118 Vermont Yankee Nuclear Power Station Techi,; col Specifications Prepssed Change No. 205 Desenphon and Bases for Changes Paoe 6 of 9 No.

Page Section Description and Basis for Change 47 56 T3.2.8 Notes Change footnote heading from ' Table 3.2.7" to

  • Table 3.2.8" Corrects error by providing the proper Table number 48 57 T3.2.9 Change: Add cuiviponent identification numbers Changes nomenclature by designating cunipOnent identificaten numbers of associated instrumentation with trip functions. This achieves consistency with other Technical Specific Juns where cenipsnent identification numbers are already included An additional benefit to including cui ipOnent numbers in the Technical Specifications is the avoidance of confusion and the potential for errors 49 63 T4.2.1 Change: Move Note 4 from two places in " Trip Funcbon* column to "Functonal Test" column

=

Corrects error in column location where note occurred in the Table, consistent with other Technical Specifications; there is no change to existing requirements by this change 50 71a T4.2.7 Change: Inserts a new page For consistency and clanty within the Technical Spin,;Tn,.tions, this change notes that Table 4.2.7 was intentionally deleted.

51 74 T4.2 Notes Change: In Note 4, change the fourth word of the first sentence from " expected

  • to " excepted".

e Corrects a typographical error 52 81a 3.3.A.2 Change " control rod dnven* to " control rod drives" in the 1" line

=

Corrects a typographical error 53 88 3.3.F e

Change " Specification" to "Spedin ";uns* in the 1" line Corrects a typographical error 54 88 3.3.F

=

Change "3.3B through D" to "3.3.B through 3.3.D*

Corrects a typographical error and clanfies this Spedric."Jun to achieve consistency within the Technical Specifications.

55 90 B3.3/4.3 Change, " report" to " Report" in item #4 Corrects a typographical error 56 92 4.4.A e

Change: Re-number second set of paragraphs from *1* and *2' to "3" and *4*

Corrects a typographical enor and/or achieves consistency in numbenng of paragraphs within the Technical Specifications 57 93 4.4.A Change: Re-number *3* and *4" to *S* and "6" Corrects a typographical error and/or achieves consistency in numbenng of pr=.y.phs within the Technical Specifications 58 105 3.5.D.3 Change " subsystem" to

  • subsystem (s)* in the 11" and 16" lines Corrects a typographical or grammahcal error and achieves consistency unthm the Technical Specificatens.

Depending upon the circumstances, one or more subsyatems may be affected i

svYset tea; ociober 30.1998 l

w,-

4 Attachment A 13 BVY 98-118 Vermont Yankee Nuclear Power Station Technical Specifications Proposed Change No. 205 Description and Bases for Changes Paoe 7.of 9 No.

Page Section Description and Basis for Change Change " subsystem

  • to " subsystem (s)* in the 7" line 59 105 4.5.D.3 Corrects a typographical error and/or achieves consistency within the Technical Specifications. Depending upon the circumstances, one or more subsystems may be affected Change *.. reduced to 120 psig..." to "... reduced to 5120 psig..." in the 7"line 60 106 3.5.E.3 Clarifies the intent of the corrective action required and is at least as restnctive as the current requirement.

This was possibly a typographical error of omission. Corrects the wording of the Technical Specification to achieve consistency within the Technical Specifications in addressing process variable limits Change "... reduced to 100 psig..." to "... reduced to 5100 psig..." in the 7" line 61 107 3.5.F.3

=

Clanfies the intent of the corrective action required and is at least as restnchve as the current requirement.

This was possibly a typographical error of omission. Corrects the wording of the Technical Specification to achieve consistency within the Technical Specifications in addressing process vanable lirnits Change *.. normal operating pressure..." to ".. normal reactor operating pressure...* In the 4" line from bottom 62 107 4.5.G.1 of page Clarifies and adds consistency within the Technical Specifications by clanfying this Specification, which is similar to Technical Specification 4.5.E for HPCI system (may have been a typographical error)

Change "... reduced to 120 psig..." to "... reduced to 5120 psig..." In the 7" line 63 108 3.5.G.3 Clarifies the intent of the corrective acbon required and is at least as restrictive as the current requirement.

This was possibly a typographical error of omission. Corrects the wording of the Technical Specification to achieve consistency within the Technical Specifications in addressing process vanable limits Change " standby diesel generators" to

=

Adds consistency to the Technical Specifications by using the same equipment termmology (e.g., Technical Specification 3.10.A.1)

Change *.. Low Pressure Core Cooling and Containment Cooling..." to "...LPCI, Core Spray and Containment 65 108 3.5.H.1 Cooling..."in the 9* and 10* lines Adds consistency and spediidly to the Technical Specifkations by usmg the same equipment terminology used elsewhere in the Technical SpedTat;uns Change " standby diesel generators" to " emergency diesel generators

  • in the 1" line 66 108 4.5.H.1 Adds consistency to the Technical -Ws by using the same equipment terminology (e.g., Technical SpedTet;un 3.10.A.1) l 1

BVY98118A. october 30,1998 i

_. = - _

=,

Attachment A to BVY 98-118 Vermont Yankee Nuclear Power Station

% <l Technical Specifications Proposed Change No. 205 Description and Bases for Changes.

Pace 8 of 9 No.

Page Section Description and Basis for Change Change chlonde ion concentration from *0.01 ppm' to *0.1 ppm" in the 10" line 67 118 3.6.B.2 This change corrects a typographical error. By letters dated May 4,1994 (BW 94-49) and July 19,1994 (BW 94-74) WNPC submitted to NRC reformatted versions of the Technical Spedric t;oris to change page orientation from landscape to portrait format. Due to a typographical error, this value was ;iw.,visec.ity transcribed by WNPC at that time. A review of the docket confirms that the subject value in the initial WNPS Technical Speedication was 0.1 ppm, and the only change to this page (Amendment 91 issued on October 28 j

1985) did not change this value.

Change "3.6.B.* to "3.6.B* in the 1" line 68 119 3.6.B.5 Corrects a typographical error by deleting a period Change "CFR" to *10CFR* in the 3" line of the 3" paragraph 7

69 140 B3.6/4.6 Corrects a typographical error and/or adds consistency and specifiedy to the Technical Speedications Change the section heading from " Coolant Chemistry

  • to *B. Coolant Chemistry
  • 70 140 B3.6/4.6 Corrects a typographical error and adds consistency to the Technical Spedric ticiis by alpha-numerically designating sections of the Technical Specifications Change "3.8.C.1a* to "3.8.E.1" in the 4" line of the 4" paragraph on the page 71 140 83.6/4.6 Corrects e typographical or administrative error in referencing the appropiiate Technical Speedication I

Change ' postulate" to " postulated

  • in the 4" line of the 5" paragraph on the page 72 140 B3.6/4.6 Cctrects a typographical or administrative error in using the proper verb tense

+

Change "4.6.B.2* to ~4.6.B.1.b" in the 5" line of the 1" paragraph on the page 73 142 B3.6/4.6 Corrects a typographical or administrative error in referencing the appropiioie Technical Speedication Change " leakage;" to " leakage," in the 6" line of the 1" paragraph 74 142 B3.6/4.6.C Corrects a typographical or administrative error in using the proper form of punctuation Change " Table 4.2-4* to " Table 4.2-3* in the 1" line 75 142a B3.6/4.6.E Corrects a typographical or administrative error in referencing the oppivpiiate Technical Spedric,.i;vii Change "3.7* to "4.7" in the heading 76 166a B3.7 Corrects a typographical or admirsistrative error in appropriately designating this section of the Bases to the Technical Speedications Change "will be* to "was* in the 5" line of the 1" paragraph 77 168 B4.7.A Corrects a typographical or administrative error in using the proper verb tense Change: Add component identification numbers in three places 78 193 T3.9.1 Changes nomenclature by designating component identification numbers of associated instrumentation with trip functions. This achieves consistency with other Technical Speedications where component identification numbers are already included An additional benefit to including component numbers in the Technical Specifications is the avoidance of confusion and the potential for errors i

BVY98118A; odober 30,1998 1

0

~

l Attachment A to BW 98-118 Vermont Ycnkee Nuclecr Power Station i

Technical Specifications Proposed Change No. 205 Description and Bases for Changes i

Pace 9 of 9 i

No.

Page Section Description and Basis for Change Change: Add component identification numbers in several places 79 195 T3.9.2 Changes nomenclature by designating component identification numbers of usociated instrumentation with trip functions. This achieves consistency with other Technical Specificabons where component identification numbers are already included An additional benefit to including wiviperie it numbers in the Technical Specifications is the avoidance of confusion and the potential for errors Change "meteorlogical" to " meteorological" in the 5" and 10" lines in the second column 80 198 T3.9.3 Corrects a typographical error Change: In the 4" line under note (a), add a *<* (less than symbol) before the "1.0" and delete the period after 81 202 T3.9.4 Notes

  • 1.0" Corrects a typsy.pii cal or administrative error by adding a necessaiy symbol i

Change " indicate

  • to " indicates" in note (1)(a) 82 206 T4.9.2 Notes Corrects a typsy.ytiical or administrative error in using the proper verb tense

=

Change *.. Regulatory Guides 4.3 (C.2.a) and 4.1 (C.2.b)... to "... Regulatory Guide 4.1 (C.2.b)..." in the 10" 83 209 B3.9.C l

line of the 2"' paragraph Corrects an error by removing reference to Regulatory Guide 4.3 which is no longer active and has been withdrawn by the NRC.

Change

  • control rods" to " control rod's" in the 4" line 84 233 4.12.E Corrects a typographical or administrative error in grammar Change " Specification 3.2" to " Specification 3.3" in the 6" line of the 2" paragraph 85 237 B3.12/4.12.A Corrects a typographical or administrative error in referencing the oppivpii ie Technical SpedTcation Change *3.12.C.2" to "3.13.C.2" in the 2" line 86 244 3.13.C.1 Corrects a typographical or administrative error in referencing the appropnate Technical Specification Change the paragraph designation from "d." to "c."

87 249 4.13.G.1.d Corrects a typographical or administrative error in sequentially designating this sechon. There currently is no Technical Specifications section 4.13.G.1.c Change: Separate item #2 "Switchgear Room

  • into two fire areas and re-number the remaining list of sensors 88 250 T3.13.A.1 Dividing the switchgear room into two designated areas achieves consistency with how other rooms and fire areas are specified for fire detechon in the Technical Spedric.tions and also achieves consistency with the 1982 plant derign change which divided the switchgear room into two (east asid west) fire areas. This design change was originally i iccipeirsted into Technical SpedTn,.Tviis in Amendment No.154 dated March 6,1998, except for the associated changes to this Table. This change also adds additional restnchons by ensunng that at least ten operable fire detechon sensors will be in each fire area (i.e., east and west areas).

Notes:

1. Page arvi Section numbers refer to the current (NRC-approved) version of WNPS Technical Specifications
2. Txxx under the Section heading denotes a table. Bxxx denotes a Bases sechon BVY98118A Ochtm 30.1998 J

.