Amend 96 to License DPR-3,modifying Tech Specs to Replace Manual Containment Isolation Valve W/Blank Flange
ML20199D534
Person / Time
Site: Yankee Rowe
(DPR-03-A-096, DPR-3-A-96)
Issue date: 06/09/1986
From: Mckenna E
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20199D531 List:
References
NUDOCS 8606200371
Download: ML20199D534 (7)


Text

-m

[ge @scdqfo UNITED STATES

+

~g

![

g NUCLEAR REGULATORY COMMISSION O

E WASHINGTON, D. C. 20555 e..

YANKEE ATOMIC ELECTRIC COMPAN1 DOCKET NO.50-029 YANKEE NUCLEAR POWER STATION AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 96 License No. DPR-3 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment by Yankee Atomic Electric Company (the licensee) dated January 8, 1986 complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Comission's rules and regulations set forth ir, 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment and Paragraph 2.C.(2) of Facility Operating License No. DPR-3 is hereby amended to read as follows:

8606200371 e60609 PDR ADOCK 05000029 P

PDR

.. -(2)

Technical Specifications The Technical Specifications contained in Appendix A as revised through Amendment No.96, are hereby incorporated in the license. The licensee shall operate the facility in acco'rdance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION blCJ Eileen M. McKenna, Project Manager Project Directorate #1 Division of PWR Licensing-A

Attachment:

Changes to the Technical Specifications Date of Issuance:

June 9, 1986

ATTACHMENT TO LICENSE AMENDMENT NO. 96 FACILITY OPERATING LICENSE NO. DPR-3 DOCKET NO.'50-029 Revise Appendix A Technical Specifications by removing the pages identified below and inserting the enclosed pages. --The revised pages are identified by the captioned amendment number and contain marginal lines indicating the area of change.

REMOVE INSERT 3/4 6-11 3/4 6-11 3/4 6-12 3/4 6-12*

3/4 6-13 3/4 6 3/4 6-14 3/4 6-14*

  • 0verleaf page provided to maintain docume.;t completeness.

No changes contained on this page.

TABLE 3.6-1 CONTAINNENT BARRIERS TESTABLE DURINC ISOLATION VALVE WUMBER FUNCTION PLANT OPERATION TIME (Yes or No)

(Seconds)

A.1 AUTOMATIC ISOLATION VALVES (Subject to Type C Testing)

VD-TV-202 Main Coolant Drain Yes 30 VD-TV-203 Main Coolant Vent Yes 30 VD-TV-204 Valve Stem Leakoff Yes 30 SA-TV-206 Main Coolant Sample Yes 30 SA-TV-207 Neutron Shield Tank Sample Yes 30 VD-TV-209 Containment Drain Yes 30 SW-TV-408 Containment cooling Water Return Yes 30 SW-TV-412 Containment Cooling Water Inlet Yes 30 HC-TV-409 Containment Heating Condensate Return Yes 30 HC-TV-413 containment Heating Steam Supply Yes 30 PR-TV-214 Safety Discharge Header No 30 CH-LCV-222 Main Coolant Bleed Yes 30 A.2 AUTOMATIC ISOLATION VALVES ( M Subject to Type C Testing)

B.1 MANUAL VALVES (Subject to Type C Testing)

CS-V-601 Shield Tank Cavity Fill NA NA CA-V-746(3)

Containment Air Charge NA NA HV-V-5 Containment H2 Vent System NA NA HV-V-6(8)

Containment H2 Vent System NA NA HV-V-34(8)

Containment H2 Vent System NA NA CA-V-688 Containment Service Air Supply NA NA CA-V-834 Containment H2 Vent System Air Supply NA NA l

VD-V-1107(10)

Containment Sample NA NA VD-V-1108(10)

Containment Sample NA NA CA-V-1275(8)

H2 Recombiner Inlet Tap NA NA

+

CA-V-1276(8)

H2 Recombiner Inlet Tap NA NA CA-V-1277(3)

Containment Air Charge NA NA YANKEE ROWE 3/4 6-11 Amendment No.

,g

]

O s

TABLE 3.6-1 (continued)

CONTAINMENT BARRIERS (p

TESTABLE DURING ISOLATION PLANT OPERATION TIME VALVE NUMBER FUNCTION (Yes or No)

(Seconds)

VD-V-752(4)

Neutron Shield Tank-Outer Test NA NA VD-V-754(4)

Neutron Shield Tank-Inner Test' NA NA

~

HC-V-602 Air Purge Bypass NA NA CA-V-755(6)

VCPH Pressure Relief NA NA PU-V-651 Containment Sump to Charging NA NA VD-V-917 LPST S.V. Discharge Header NA NA

~

8.2 MANUAL VALVES (Not Subject to Type C Testing)

C.

CHECK VALVES (Not Subject to Type C Testing)

~

SI-V-14 Safety Injection (HP)

NA NA CS-V-621 Safety Injection (LP)

NA NA CH-V-611 MC Faed to Loop #4 NA NA D.1 REMOTE MANUAL VALVES (Subjec.t to Type C Testing)

CC-TV-205(5)

Component Cooling Return No NA CC-TV-208(5)

Component Cooling Inlet No NA

{

l HV-50V-39 Hydrogen Monitoring Yes NA HV-50V-42 Hydrogen Monitoring Yes NA D.2 REMOTE W.NUAL VALVES (Not Subject to Type C Testing)

SC-MOV-551/

Shutdown Coolins In No NA 553(1,2) l SC-MOV-552/

Shutdown Cooling Dut No NA I

554 (1,2)

CH-MOV-522f) MC Feed-to-Loop Fill Header No NA I

SI-MOV-516 ECCS Recirculation No NA SI-MOV-517

'ECCS Recirculation No NA i

YANKEE R0WE 3/4 6-12 Amendment No. H k,86 1

--e

i TABLE 3.6-1 (continued)

CONTAINMENT BARRIERS TESTABLE DURING ISOLATION VALVE NUMBER FUNCTION PLANT OPERATION TIME (Yes or No)

(Seconds)

E.1 BARRIERS (Subject to Type B Testing)

Domineralized Nater Supply (Blank Flange)

NA NA Cavity Purification (Blank Flange)

NA NA L.P. Vent Header (Blank Flange)

NA NA Personnel Airlock NA NA Electrical Penetrations MA NA Fuel Chute (Blank Flange)(9)

NA NA Air Purge Inlet (Blank Flange)

NA NA Air Purge Outlet (Blank Flange)

MA NA LPST Safety Valve Discharge Header 5 Blank Flanges NA NA Fuel Chute Dewatering Pump Discharge (Blank Flange)

NA NA l

E.2 ~ BARRIERS (Egi Subject to Type B Testing) 18" Bolted Manway EA NA Containment Les Expansion Joints WA NA Fuel Chute Expansion Joints (9)

NA NA Equipment Hatch NA NA Containment Top Manhole Cover NA NA Containment Bottom Manhole Cover NA NA Pressurizer Heise Gauge Line NA NA Containment Pressure Sensing Lines (two)

NA NA F.

SAFETY VALVES (Subject to Type C Testing)

SV-215 LPST Safety Valve (9)

NA NA SV-223 Valve Stem Leakoff Safety Valve NA NA SV-227 CCST Safety Valve NA NA e

Am.nds.ntNo.g.e m EEE oNE 3,.. 13

1 TABLE 3.6-1 (continued)

CONTAINMENT BARRIERS TESTABLE DURING ISOLATION PLANT OPERATION TIME VALVE NUMBER FUNCTION (Yes or No)

(Seconds)

G.1 SECONDARYAUTOMATICISOLATION(NotSubjecttoAppendixJ)( 1 TV-411 Atmospheric Steam Dump Yes 30

~

TV-406 Main Steam Drain to Condenser Yes 30 TV-401A No. 1 SG Blowdown Yes 30 TV-401B No. 2 SG Blowdown Yes 30 TV-401C No. 3 SG Blowdown Yes 30 TV-401D No. 4 SG Blowdown Yes 30 NRV-405A Main Steam Non-Return Valve No 5

NRV-405B Hain Steam Non-Return Valve No 5

NRV-405C Main Steam Non-Return Valve No 5

NRV-405D Main Steam Non-Return Valve No 5

G.2 SECONDARY MANUAL ISOLATION (N:,t subject to Appendix J) (11,12)

MS-V-627 Main Steam Bypass NA NA MS-V-628 Main Steam Bypass NA NA MS-V-629 Main Steam Bypass NA NA MS-V-630 Main Steam Bypass NA NA SI-V-701 SI to Alternate SG Feed NA NA VD-V-1157

$$$ to Alternate SG Feed NA NA I

I AS-V-719 Emergency Feedwater Pump Steam Supply NA NA AS-V-720 Steam Drain NA NA BF-V-815 Manual Flow Control Bypass NA NA BF-V-816 Manual Flow Control Bypass NA NA BF-V-817 Manual Flow Control Bypass NA NA BF-V-818 Manual Flow Control Bypass NA NA CF-V-606 Chemical Feed NA NA CF-V-607 Chemical Feed NA NA CF-V-608 Chemical Feed NA NA CF-V-609. '

chemical Feed NA NA YANKEE ROWE 3/4 6-14 Amendment No. 69,86 G

-