ML20199C332

From kanterella
Jump to navigation Jump to search
Requests Closure of SER Confirmatory Item 4 Re NSCW Cooling Tower Seepage Test for Unit 2.Unit 2 Towers of Identical Design & Const as Unit 1 Towers,Which Had Seepage Losses of 1 & 2 Gpm.Tower Basins Retain Required Water Inventory
ML20199C332
Person / Time
Site: Vogtle  
Issue date: 06/13/1986
From: Bailey J
GEORGIA POWER CO.
To: Youngblood B
Office of Nuclear Reactor Regulation
References
0533V, 533V, GN-944, NUDOCS 8606180072
Download: ML20199C332 (1)


Text

c Georgia Power Company Rout 2 2, Box 299A Wayrr.sboro, Georgia 30830 Telephone 404 554 9961 404 724-8114 Southern Company Services, Inc Post Office Box 2625 M

Birmingham, Alabama 35202 Telephme 205 870-6011 Vogtle Proj.ect June 13, 1986 Director of Nuclear Reactor Regulation File: X7BC35 Attention:

Mr. B. J. Youngblood Log:

GN-944 PWR Project Directorate #4 4

Division of PWR Licensing A U. S. Nuclear Regulatory Commission Washington, D.C.

20555 NRC DOCKET NUMBERS 50-424 AND 50-425 CONSTRUCTION PERMIT NUMBERS CPPR-108 AND CPPR-109 V0GTLE ELECTRIC GENERATING PIANT - UNITS 1 AND 2 SER CONFIRMATORY ITEM 4: NSCW COOLING TOWER SEEPAGE TEST

Dear Mr. Denton:

The Vogtle SER required that the capability of the ultimate heat sink (UHS) be verified with respect to inventory loss due to seepage. As noted in the SER, your staff calculated that the UHS capability would not be adversely affected for losses less than 15 gpm. GPC was required to test the tower basins and verify that the seepage rate would not exceed 10 gpm for each tower. GPC performed the required tests and found the seepage loss for Unit 1 NSCW tower A to be 1 gpm and tower 2 to be 2 gpm.

The Unit 2 NSCW towers are of identical design and construction as the Unit 1 towers. This fact, plus the most favorable results of the Unit 1 tests, adequately demonstrates the capability of the tower basins to retain the required water inventory.

It is therefore respectfully requested that tests for the Unit 2 NSCW tower seepage not be performed and that this item be closed in a supplement to the SER.

If your staff requires any additional information, please do not hesitate to contact me.

" *** I'.

8606180072 860613 PDR ADOCK 0S000424 h.

PDR E

J. A. Bailey Project Licensing Manager JAB /caa xc:

R. E. Conway G. Bockhold, Jr.

R. A. Thomas NRC Resident Inspector J. E. Joiner, Esquire D. C. Teper B. W. Churchill, Esquire W. C. Ramsey M. A. Miller L. T. Gucwa B. Jones, Esquire Vogtle Project File ff(>C) l 0533V If()