reuter-stokes
- i..&
Edison Park 0-r 8499 Darrow Road
'g Twinsburg, Ohio 44087 January 20, 1986 i
l f
216/425-3755 Telex 985253 U. S. Nuclear Regulatory Commission Materials and Licensing Section-Region III 7"
g 799 Roosevelt Road m
Glen Ellyn, IL 60137
(
g; o
E P3
SUBJECT:
Reuter-Stokes, Inc.
9 N
2 Special Nuclear Material License C
]
No. SNM-1826 I
a E
3 Gentlemen:
g Reuter-Stokes requests to amend NRC License Number SNM-18?6 according to 10CFR70.34.
Under the current provisions of condition 10.A.,
B.,
and C.,
Reuter-Stokes fission counters and chambers containing special nuclear material may be distributed with a maximum quantity of 4 grams per device. The proposed amendment involves an addition to the existing conditions under provision 10, a new device model will be included so that provision 10 will ncw read as follows:
- 10. The following Reuter-Stokes fission counters and chambers containing special nuclear material may be distributed:
Maximum Quantity Device Model No.
Isotope Per Device A.
RS-P6 Series Uranium (Principal 4 grams (Proportional Isotope U-235)
Counters)
B.
RS-C3 Series Uranium (Principal 4 grams (Ion Chambers)
Isotopes U-234 e
and U-235) m rng 3
z C.
RS-C6 Series (In-Core Uranium (Principal 24] grads y
Ion Chambers)
Isotopes U-234, U-235, and E
g a
U-234/U-235) 0.
RS-P6-1596-201 Series Uranium (Principal
<25 gra8s (Long Fission Chambers)
Isotope U-235)
Accordingly, Reuter-Stokes intends to maintain the other conditions of the license and thoroughly follow through with physical security plans as reporkeq)to your office on March 17, 1980. Our security plans have met the requirqmbTts of by the office of Physical Security Licens 4Brang -
10CFR73.67 as determined p
Division of Safeguards,
- continued -
N 8606170278 860415 OY
$ t $ 70 COMROLNO. 8 0 5 4 3 M\\ 2 3 E3 PDR
_J
$ reuter-stokes Dison Pak Twinsbwg. Ohio 44087 January 20, 1986 Page 2 - continued The requested addition to the license will make it possible to develop model RS-P6-1596-201 long fission counter, which has an increased total quantity of U-235 incorporated into its design. Modification to the amount of U-235 was necessary for achieving greater sensitivities. The first developed product of this device will be manufactured for the Department of Energy per contract number 01-83ER80088.00.
Enclosed is a check for $120.00, as specified in fee category 1K. Also enclosed for your review are the preliminary specifications and drawing of the fission counter. If you find that you need further information, please call or write.
Sincerely, REUTER-ST0KES, INC.
kOMW f AAed.
Eileen Openbrier Staff Health Physicist E0:cln enc.
l l
e
(~) reuter-stokes September 4, 1985 PRELIMINARY SPECIFICATIONS RS-P6-1596-201 HIGH SENSITIVITY FISSION COUNTER MECHANICAL Ma x imum d i amet er................................. 47. 7 5 cm Maximum overall longth (body only)............... 24.70 cm Connectors......................................... Type HN MATERIAL Outer shell and inner electrodes........... Stainless Steel Connector.................................. Stainless Steel Cable...................................... Stainless Steel Insulation:
Detector......................A1umina Ceramic Connector..............................Tef l on Cab 1 e................................. Al umina 235 Neutron sensitive material.... Uranium enriched 93% in U 235 Total quantity of U
.............................. 24 gr Fill gas............................. 76 cm Hg - Argon /CF4 CAPACITANCE......................................... 2000 pf RESISTANCE 9 25"C.......................
1012 ohms (minimum)
MAXIMUM RATINGS Voltage......................................... 800 Volts r
Temperature......................................... 200 C i
Burn-up life:
20 for 10% decrease in sensitivity... 2 X 10 nyt(thermal)
TYPICAL OPERATING CHARACTERISTICS Thermal neutron sensitivity............. 17.6 cps /nv + 20%
3 l
Thermal neutron flux range.....................to 4 X 10 nv Voltage range............................ 300 to 800 Volts Output pulse characteristics (average)
Charge output........................ 3 X 10~I4 coulombs Collection time.........................
25 nanoseconds coNTROLNO. 8 0 5 4 3
{