October 30, 1997 4
Ms. Gayle F. Elliott, Manager Safsty and Licensing Framatome Cogema Fuels Lynchburg Manufacturing Facility P.O. Box 11646 Lynchburg, Virginia 24506-1646
SUBJECT:
ORGANIZATIONAL CH'd'uES (TAC NO. L30994)
Dear Ms. Elliott:
This refers to your application dated June 9,1997, requesting an amendment to Materials License SNM-1168. Our review of your application has identified additional information that is needed before final action can be taken on your request.
The additional information, specified in the enclosure, should be provided within 30 days of the date of this letter. Please reference the above TAC No. in future correspondence related to this request.
We are concerned that several sections (i.e.,4.1.2,4.1.6.2,4.1.6.5,4.2.3.3,4.2.4.4,4.2.4.6, and 4.2.4.7) contained numerous changes that were not marked as or were not included in the summarization of changes in the amendment request. Several of the changes not marked were significant. Please be vigilant in marking all changes even if they are cosmetic in nature as they help NRC staff focus on the safety significance of the requested amendment. Please resubmit your chapter changes with all changes marked for this amendment.
If you have question regarding this matter, please contact me at (301) 415-8139.
Sincerely, Original signed by:
Michael A. Lamastra Licensing Section 2 Licensing Branch Division of Fuel Cycle Safety f 1
, U ~)
and Safeguards, NMSS Djstribution: w! encl. (Control No.100S)[ PARTIAL]
Docket 70-1201' PUBLIC~
- NRC File Center;
- FCLB R/F FCSS RIF NMSS R/F VRobin, Ril Region 11
[G:\\fram]
h OFC
- FCLB, h
FCLB /,yk C
FCLB h
FCLB 4
NAME MLa'rbstra HFelsher P3hea
&A)b 6)dihay DATE 10MI97 10!,$97 10kJ/97 10 7
{Ni" E I N g E(llIll,ll.lll I.I11 IUPS FRE EBTER COPY
pA *8Cp _
A UNITED STATES t
. j*
NU, CLEAR, REGULATORY, COMMISSION j
2
- WASHINGTON, D.C. 20064-4001 7-f
+.
October 30, 1997 m
~ Ms. Gayle F. Elliott, Manager --
t-Safety and Licensing Framatome Cogema Fuels -
^
Lynchburg Manufacturing Facility P.O. Box 11646 o
':~t'
_ O.
_ Lynchburg Virginla;24506-1646:
f SUBJECTi ORGANIZATIONAL CHANGES (TAC No. L30994)
=
Dear Ms. Elliott:
This refers to your application dated June 9,1997, requesting an amendment to Materials License SNM-1168.: Our review of your application has identified additional information that is needed before final action can be taken on your request.
Se additional information, specified in the enclosure, should be provided within 30 days of the date of this letter. Please reference the above TAC No, in future correspondence related to this request.
We are concemed that several sections (i.e., 4.1.2, 4.1.6.2, 4,1.6.5, 4.2.3.3, 4.2.4.4, 4.2.4.6, and 4.2.4.7) contained numerous cilanges that were not ma.xed or were not included in the
- summarization of changes in the amendment request. Several of the changes not marked were significant. Please be vigilant in marking all changes even if they are cosmetic in nature as they help NRC staff focus on the safety significance of the requested amendment.- Please resubmit your chapter changes with all changes marked for this amendment, if you have question regarding this matter, please contact me at (301) 415-8139.
Sincerely,,
.E
,,rs Michael A. Lamastra Licensing Section 2 Licensing Branch Division of Fuel Cycle Safety and Safeguards, NMSS Docket 7} 1201 License SNM-1168
Enclosure:
As stated 1
a 4
1
- Request for Additional Information 1
Application Dated June 9,1997 Framatome Cogoma Fuels Docket 70-1201 Please resubmit your amendment application by providing/ correcting the following information:
1.
Section 1.3 should be modified to reference the date of renewal and current expiration -
date.
2.
Section 2.1 should be modified to include the duties and responsibility of the Quality Managers.
- 3.
Section 2.6 should be modified to clearly state that following procedures is mandatory.
4.
Section 3.2.2.4 should be modified to reference which industrial standard will be followed in determining the flow rate for each fume hood. (e.g., Industrial Ventilation: A Manual of Recommended Practice, American Conference of GovemmentalIndustrial Hygienists).
5.
Section 4.1.1 should be changed from "American Nuclear Standard" to "American National Standard."
6.
Section 4.1.7 should be changed from " safe geometry" to " favorable geometry" tc, be consistent with the rest of the document.
7.
Section 4.2.3.3 should be modified such that the second paragraph should reflect that there are four basic cross section libraries and a supplementary set which is not used at Lynchburg Manufacturing Facility. Thus, the fifth numbered item should be deleted.
8.
Explain why in Section 4.2.4.7 you changed the last bullet from "other accumulations of SNM" to " storage rack" 9.
Explain the differences in Sections 4.2.4.2,4.2.4.4 and 4.2.4.5, between " nuclear safety restrictions" and " nuclear safety conditions." If there are no differences, please modify the appropriate sections for consistency.
ENCLOSURE
I e
2
]
- 10. T he following sections contain minor typographical errors and should be modified:
Section 4.2.3.3, change ' fro" to *from" and change "first four" to "the four.'
'Section 4.1.6.2, change ' box at time" to " box at a time.'
Section 4.2.1,
, 1) in the first paragraph, change " provide
- to 'provided."
(
' (2) in the third paragraph, add the comma back in after " processing."
Section 4.2.4.7, change "after prepared" to "after being prepared."