_ _ _ _ _ _ _ _ _ _ _ _ _ - - _

Stallon Support Department

$+

7 PECO NUCLEAR

..rco % c -

%5 CteshrtaxA ovuleswd A Unit of PECO Energy wayre sw 3947 w9t January 16,1998 Docket Nos. 50 277 50-278 License Nos. DPR-44 DPR 50 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Subjov Peach Bottom Atomic Power Station, Units 2 and 3 Emergency Response Data System Data Point Library Changes

Dear NRC Officials:

By letter dated October 6,1997, PECO Energy submitted an updated listing of the set of data points for the Emergency Response Data System (ERDS) data point library for Peach Bottom Atomic Power Station (PBAPS), Units 2 and 3. The information submitted contained a listing of all current ERDS data points in the library for PBAPS, Unit 2 and 3. ERDS is a direct, near real-time, electronic data link between PBAPS and the NRC's Operations Center which provides for the transmission of selected process computer data for monitoring various plant parameters. This information is required by 10CFR50, Appendix E, Section VI.S.a.

Subsequently, by letter dated November 6,1997, the NRC informed PECO Energy that the ERDS point library information submitted was incomplete and inconsistent with guidance established in NUREG 1394, Revision 1," Emergency Response Data System (ERDS)Imptomontatim."

Appendices C through I of the NUREG provide the appropriate format and background guidance for submitting ERDS data point library information. In the letter, the NRC also indicated that there should be a reference as to whether data points are being added to the data point library, or if points are intended to replace existing points in the library. As a result, the NRC requested a corrected data point library listing for PBAPS, Units 2 and 3.

9001270131 900116 PDR ADOCK 05000277 F

PDR

/,4,,

1.1 I l.ill.ll.lli.l!.Ill

Janu:ry 16,1W8 P.:43 2 Accordingly, in response to the NRC's request, the attachment to this letter provides an updatod

- lir. ling of the data point library information previously submitted in our October 6,1997 letter. The irJormation contained in the attachment only includes data for those data points that have been specifically added, replaced, or changed. The information provided is in a format consistent with the guidance specif*f in NUREG 1394, Revision 1. Each specific data point listed is annotated with a reference indicating whether the point is an addition, replacement, or change to the data point ;ibrary. T'ie complete listing of the ERDS data point library information is not being i

rusubmined. The NRC currently has the information, in the proper format, for those data points that have not been added, replaced, or changed.

+

If you have any questions or require additional information, please do not hesitate to contact us.

Very truly yours, i

9n&,4 In i

G. A. Hunger, Jr.

Director. Ucensing Attachment cc:

H J. Miller, Administrator. Region I, USNRC (w/ attachment)

L A. C. McMurtsay, USNRC Senior Resident inspector, PBAPS 9

4 L

4 k

b t-m. e si

.e w

o-+.

ms wrr,~.c-yy-+-

-g e e.

w

-,.e<-%,.

yow--,-

c-,-,

ww-es--ree.=-e.,

-,-v w m

-cwe--e

.-we,,.---

ee

--et-+--

m <

er-.

f i

s e

l i

l l

i t

9 ATTACHMENT Peach Bottom Atomic Power Station Units 2 and 3 Emergency Response Data System (ERDS)

Data Library Point Charges I

. p 9

b g

n

.,..w--


,-,-.,-,y,

,. +,

~.

4 DATA POINT LIBRARY REFERENCE FILE U/2 SYACK RAD MONITOR MOD 4

Date 7/23/96 Reactor Unt PE2 Data Feeder N/A NRC ERDS Parameter EFF GAS RAD i

Point ID J154 (Add)

Plant Spec Point De'scription MAIN STACK WRGM LO RANGE 1

Generic /Cond Gescription RadioactMty of Released Gasses Analo0/Digtal A

Engr Units / Dig States pCl/cc Engr Unts Conersion N/A Minimi m instr Range 10 Manmum Instr Range

.1 Zero Point Reference N/A Reference Pc!nt Notes N/A PROC or SENS.

S Number of Sersors 1

How Processed N/A Sensor Locations Main Stack Alarm / Trip Set Pohts None

- NI Detector Power Supply Cut off Power Lewl

.N/A NI Detector Power Supply Tum-on Power Lewi N/A instrument Falute Mode Low Temperature Compensation for DP N/A

, Transmitters Leel Reference Leg N/A

~

' Unique System Descriptirn -

Mch stack radiation wlue from 10 ran0e sensor.

a.

)

\\

DATA POINT LIBRARY REFERENCE FILE U/2 STACK RAD MONITOR MOD Date 10/30/96 Reactor Unt PE2 Data Feeder N/A NRC ERDS Parameter EFF GAS RAD Poht 10 J155 (Add)

Plant Spec Poht Descripuon hMIN STACK WRGM MO HANGE Genet /Cond Descriphon RadioactMtyof Released Gasses Analog /Dignal A

Engr Unts/ Dig States CVcc Engr Unks conversion N/A d

Minimum Instr Range 10 Ma*num Instr Range 100 Zero Poht Reference N/A Reference Poht Notes N/A PROC or SENS S

Number of Sensors 1

-- How Processed N/A Sensor Locations Main Stack

. Alarm / Trip Set Points None NI Detector Power Supply Cut-off Power Lewl N/A NI Detector Power Supply Tum-on Power Level N/A Instrument Fature Mode Low

' Temperature Compensation for DP N/A Transmtiers Level Reference Leg N/A L

Unique System Description Main stack radiation value imm mid range sensor.

e,,..

DATA POINT LIBRARY REFERENCE Fil.E U/2 STACK RAC MONITOR MOD 4

Date 10/30/96 Reactor Unt PE2 Data Feeder N/A NRC ERDS Parameter EFF GAS RAD Point ID J156 (Add)

Plant Spec Point Description MAIN STACK WRGM HIRANGE Generic /Cond Description RadioactMty of Released Gasses AnalogOigital A

Engr Units / Dig States pCVcc Engr Unts Conwrson N/A Minimum Instr Range 0.t Madmum Instr Range 2x10' Zero Point Reference N/A Reference Point Notes N/A PROC or SENS S

Numberof Sensors 1

How Processed N/A Sensor Locations Main Stack Alarm / Trip Set Points None NI Detector Power Supply Cut-off Power Level N/A NI Detector Power Supply Tuman Power Lewf N/A Instrument Failure Mode Low Temperature Compensation fnt DP N/A Transmitters Lewi Reference Leg N/A Unique System Description Main stack radiatbn value from hl range sensor.

l l

DATA POINT LIBRARY REFG"'cNCE FILE U/2 STACK RAD MONITu< MOD Date 6/7/96 Reactor Unt PE2 Data Feeder N/A NRC ERDS Parameter EFF GAS RAD Point ID J158 (Add)

Plant Spec Point Description VENT STACK WRGM LO RANGE Generic /Cond Description RadioactMty of Released Gasses Analog / Digital A

Engr Unts/ Dig States pCVcc Engr Unlis Conersion N/A e

4 Minimum lortr Range 10 Madmum Instr Range 2x10' Zero Point Reference N/A Reference Pobt Notes N/A PROC or SENS S

Numberof Sensors 1

How Processed N/A Sensor Locations Vent Ptack Alarm /frip Set Points None NI Detector Power Supply Cut-off Power Lewt N/A NI Detector Power Supply Tum-on Power Lewi N/A instrument Failure Mode Low Temperature Compensation for DP N/A Transmitters Level Reference Leg N/A Unique System Description Vent stack radiation value from lo range sensor.

DATA POINT LIBRARY REFERENCE FILE U/2 STACK RAD MONITOR MOD Date 7/23/96 Reactor Unt PE2 Data Feeder N/A NRC ERDS Parameter EFF GAS RAD Point ID J159 (Add)

Plant Spec Pohi Description VENT STACK WRGM MID RANGE Generic /Cond Description RadioactMty of Released Gasses Analog /DigPal A

Engr Units / Dig States CVcc Engr Units Conversion N!A d

Molmum Instr Range 10 Maximum Instr Range 2x10' Zero Point Reference N/A Reference Point Notes N/A PROC or SENS S

Number of Sensors 1

How Processed N/A Sensor Locations Vent Stack Alarm / Trip Set Points None NI Detector Power Supply Cut-off Power Level N/A NI Detector Power Supply Tum-on Power Lewt N/A Instrument Failure Mode Low Temperature Compensation for DP N/A Transmtters Level Reference Leg N/A Unique System Description Vent stack radiation value from mid range

sensor,

a DATA POINT LIBRARY REFERENCE FILE U/2 STACK RAD MONITOR MOD Date 6/24/96 Reactor Unt PE2 Data Feeder N/A NRC ERDS Parameter EFF GAS RAD Point ID J100 (Add)

Plant Spec Point Descriptbn VENT STACK WRGM HI RANGE Generk:/Cond Description RadioactMty of Released Gasses Analog /Digtal A

Engr Unts/ Dig States pCL/cc Engr Unts Conversion N/A Mailmum Instr Range 0.1 Madmum instr Rar0e 2x10' Zero Po!nt Reference N/A Reference Point Notes N/A PROC or SENS S

Number of Sensors 1

How Processed N/A Sensor Locations Vent Stack Alarm / Trip Set Points None NI Detector Power Supply Cut off Power Level N/A NI Detector Power Supply Tum-on Power Level N/A Instrument Falure Mode Low Temperature Compensation for DP N/A Transmitters Level Reference Leg N/A Unk ue System Description Vent stack radiation value from hl range sensor, t

b D ATA POINT LIBRARY Ri!FF".TdCE FILE U/2 STACK RAD MONITOR MOD Date 11/17/94 heactor Unt PE2 Data Feeder N/A s

NRC ERDS Parameter-CND A/E RAD Point ID MOO 2 (Ohange)

Plant Spec Point Desulption OG RAD (SJAE DISH)

Generic /Cond Dese,ription Condenser Air Ejector Analog! Digital A

Engr Units / Dig States MR/HR Engr Units Conwmion N/A Minimum instr Rat.ge 1

MaWmuin Instr Range 10' Zero Point Referenco N/A 4

Reference Point Notes N/A PROC or SENS -

S Number of Eu sors 1

How Processed N/A Sensor Locations Off Gas Sample Pipe AlamVTrip Set Points hihi?OO. hi61 NI Detector Power Supply Cut off Power Level N/A NI Detector Power Supply Turn-on Power Les el N/A Instrument Failure Mode Lew Temperature Coinpensation for DP N/A Transmitters Level Reference LeC N/A f

Unique System Description Mc::Rors reactMty of steam lct air ejectors discharge

i DATA POINT LIBRARY REFERENCE FILE U/2 STACK RAD MONITOR MOD Date 10/30/96 Reactor Unil PE2 Data Feeder N/A NRC ERDS Parameter EFF GAS RAD Point ID SPDS1287 (Change)

Plant Spec Point Descr'ption AVG MN STACK RAD-NRW/ WIDE RNG Generic /Cond Description RadbactMty of Released Gasses Analog / Digital A

Engr Units / Dig States pCVcc Engr Units Conversion N/A Minimum Instr Range 10 MaWmum Instr Range 10' Zero Point Reference N/A Reference Point Notes N/A PROC or GENS P

Number of Sensors N/A How Processed Range selected value Sensor Lo?ations McIn Stack Alarm / Trip Set Points hihl102, hi 10" NI Detector Power Supply Cut-off Power Lewl N/A NI Detector Power Supply Tum-on Power Lewl N/A instrument Failure Mode N/A Temperature Compensation for DP N/A Transmitters i

Ltvel Reference Leg N/A Unique System Description Range selected value from points J154, J155, J156, main stack 19, mid, and hl range sensors.

h&

e

~

l

- DATA PC!NT LIBRARY REFERENCE FILE U/2 STACK RAD MONITMt MOD Date 10/10/96 Reado'r Unk PE2 Data Feeder N/A NRC ERDS Parameter EFF GAS RAD Point ID SPDS1288 (Change)

Plant Spec Point Description AVG VNT STACK RAD-NRWfMDE RNG Generic /Cond Descriptio.,

R1dioactMt!of Released Gasses Analog / Digital A

Engr Ur.its/ Dig States Cl/cc Ergr Unts Conwrsion N/A Phnlmum Instr Range 10

MaMmun. instr Range 10' Zero Point Referenca N/A Reference Point Notes N/A PROC or SENS P

Number of Sensors 3

How Processed Range seiected value Sensor Locations Vent Stack Alarm / Trip Set Points hihi 5x10'S(Run mexte only)

NI Detector Power Supply Cut-off Power Lewt N/A NI Detector Power Supply Tum-on Power Lewi N/A instrument Failure Mode N/A Temperature Compensation for DP N/A Transmitters Lewi Reference Leg N/A Unique System Description.

Range selected value from points J158, J159, J160, wnt stack lo, mid, hl range densors.

DATA POINT LIBRARY REFERENCE FILE U/3 WIDE RANGE MOL Date 10/17/97 Reador Unt PE3 Data Feeder N/A NRC EROS Parameter NI Source RNG Point 10 C529 (Rept:ces SPDS0522)

Plant Spec Point Description AVG WRNM PERCENT POWER Generic /Cond Description Nuclear Instruments, Source Ranga Analog / Digital A

Engr Units / Dig States

% power Enpr Unts Conversion N/A 4

Minirnum Instr Range 10 MaWmum Instr Range 100 Iero Point Reference N/A Reference Point Notes N/A PROC or SENS P

Number c' Oensors 4

Haw Processed Healthy Awrage Sensor Locations N/A Alarm / Trip Set Points None NI Detector Power Supply Cut-off Power Lewi N/A NI Detector Power Suppt Tum on Power Lewi N/A Instrument Failure Mode Low

. Temperature Compensation for DP N/A Transmhters Lawl Reference Leg N/A Unique System Description Awrap of the source range channels C, D, E, F. Any value not considered reasonable is omitted from the awrage.

WRNM - Wide Range Neutron Monitoring

, _ _ - _ - - _ _ _ _ = _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _____ - - _ -

4

- DATA POINT LIBRARY REFERENCE FILE U/3 STACK RAD MONITOR MOD Date 10/30/96 3

Reactor Unit PE3 Data Feeder N/A NRC EROS Parameter EFF GAS RAD Point ID J656 (Add)

Plant Spec Point Description MAIN STACK WRGM HI RANGE Generictond Descripton RadioactMy of Released Gasses Analog / Digital A

Engr Units /D*g States Cl/cc Engr Units Conwrsion N/A Minimum Instr Range

.1 5

MaWmum Instr Range 10 Zero Point Reference N/A a

Reference Point Notes N/A PROC or SENS S

Numberof Sensors 1

How Processed N/A Sensor Locations Main Stack Alarm, Trip Set Points None 3

NI Detector power Supply Cut off Power Lewi N/A NI Detector Power Supply Turn on Power Lewi N/A instrument Failure Mode Low Temperature Compensation for DP N/A Transmitters Lewi Reference Leg N/A Unique System Description Main stack radiation value from hi sensor.

DATA POINT LIBRARY REFERENCE FILE U/3 STACK RAD MONITOR MOD Date 11/17/94 Reador Una PE3 Data Feeder '

N/A NRC ERDS Parameter CND A/E RAD Point ID M302 (Change)

Ptant Spec Point Description OG RAD (SJAE DISH)

Generic /Cond Description Condenser Air Ejector Analog / Digital A

Engr Units / Dig States MR/HR Engr Units Cenwrsion N/A Minimum Instr Range 1

8 Manmum instr Range 10 Zero Point Reference N/A Reference Point Notes N/A PROC or SENS S

Number of Sonsors 1

How Processed N/A Sensor Locations OFF GAS SAMPLE PIPE 20 TAT Alarrr/ Trip Set Points hihi700, hl252 NI Detect Power Supply Cut-off Power Level N/A N1 Detector Power Supply Tum-on Power Level N/A Instrument Failure Mode Low Temperature Compensation for DP N/A Transmitters Lewt Reference Leg N/A Unique System Description Monitors radioactMty of steam Jet air ejectors discharge.

l I

DATA POINT LIBRARY REFERENCE FILE UI3 STACK RAD MONITOR MOD Date 9/12/96 Reactor Unit PE3 Data Feeder N/A NRC ERDS Parameter EFF GAS RAD Point ID SPDS1588 ' Change)

Plant Spec Point Description AVG VNT STACK RAD-NRW/ WIDE RNG Generic /Cond Description Rac'ioactMty of Released Gasses Analog / Digital A

Engr Units / Dig States CVcc Engr Units Conwrsion N/A Minimum Instr Range 10

Maximum Instr Range 10' Zero Point Reference N/A Reference Point Notes N/A PROC or SENS P

Number of Sensors 3

How Processed Range selected value Sensor Locations Vent Stack Alarm / Trip Set Points hihi5x10'5 (run mode only)

NI Detector Power Supply Cut-off Power Lewt N/A 7

N1 Detector Power Supply Tum-on Power Lewi N/A Instrument Failure Mods N/A Temperature Compensation for DP N/A Transmitters Lewi Reference Leg N/A Unique System Description Range selected value from points J658, J65",

J660, wat stack 10, mid and hl range sensors.

I DATA POINT LIBRARY REFERENCE FILE U/3 STACK RAD MONITOR MOD Date 4/18/96 Reactor Unit PE3 Data Foeder N/A NRC ERDS Pa,ameter EFF GAS RAD Point ID J658 (Add)

Plant Spec Point Description VENT STACKWRGM LO RANGE Generic /Cond Description RadioactMty of Released Gasses Analo0/ Digital A

Engr Units / Dig States pCi/cc Engr Units Conwrsion N/A Minimum Instr Range 10' Madmum Instr Range 2x10' Zero Point Reference N/A Reference Point Notes N/A PROC or SENS S

Number of Sensors 1

How Processed N/A Sensor Locations Vent Stack Alarm / Trip Set Points None NI Detector Power Supoly Cut off Power ewi N/A NI Detector Power Supply Tum-on Power Lewt N/A Instrument Failure Mode Low Temperature Compensation for DP N/A Transmitters Lewi Reference Leg N/A Unique System Description Vent stack radiation value from lo range sensor.

d DATA PolNT LIBRARY REFERENCE FILE U/3 STACK RAD MONITOR MOD Date 10/30/96 Reactor Unll PE3 Data Feeder N/A NRC JDS Parameter EFF GAS RAD Point ID J659 (Add)

Plant Spec Point Description VENT STACK WRGM MID RANGE Generic /Cond Description RadioactVy of Released Gasses Analog / Digital A

Engr Units / Dig States Ci/cc Engr Units Conwrsion N/A d

Minimum instr Range 10 MaMmum Instr Range 2x10' Zero Point Reference N/A Reference Point Notes N/A PROC or SENS S

Number of Sensors 1

How Processed N/A Sensor Locations Vent Stack Alarrn/ Trip Set Points None NI Detector Power Suppiy Cut-off Power Level N/A NI Detector Power SupplyTum-on Powe Level 14/A Instrument Failure Mode Low Temperature Compensatbn for DP N/A Transmitters Level Reference Leg N/A Unique System Description Vent stack radiation value from n.d range sensor.

4 DATA POINT LIBRARY REFERENCE FILE U/3 STACK RAD MONITOR MOD Date 6/24/96 Reactor Unit PE3 Data Feeder N/A NRC ERDS Parameter EFF GAS RAD Point ID J660 (Add)

Plant Spec Point Description VENT STACK WRGM HI RANGE Generic /Cond Description RadioactMty of Released Gasses Analog / Digital A

Engr Units / Dig States Cl/cc Engr Units Conwrsion N/A Minimum instr Range

,1 5

Madmum instr Range 10 Zero Point Reference N/A Reference Point Notes N/A PROC or SENS S

Number of Sensors 1

How Processed N/A Sensor Locations Vent Stack Alarm / Trip Set Points None NI Detector Power Supply Cut-off Power Level N/A NI Detector Power Supply Tum-on Power Level N/A instrument Failure Mode Low Temperature Compensation for DP N/A Transmitters Level Reference Leg N/A Unique System Description Vent stack radiation value from hl range sensor.

I DATA POIN f LIBRARY REFERENCE FILE U/3 STACK RAD MONITOR MOD Date 10/30/96 lieactor Unll F23 P

Data Feeder N/A l

NRC ERDS Parameter EFF GAS RAD Point ID J655 (Add)

Plant Spec Point Description MAIN STACK WRGM MID RANGE Generic /Cond Description RadioactMty of Released Gasses Analog / Digital A

Engr Units / Dig States Ci/cc Engr Units Conwrsion N/A d

Minimum Instr Range 10 Madmum Instr Range 100 Zero Point Reference N'A

(

Reference Point Notes N/A PROC or SENS S

Number of Sensors 1

How Processed N/A Sensor Locations Main Stack Alarm / Trip Set Points None NI Detector Power Supply Cut-off Power Lewi N/A NI Detecinr Power Supply Tum-on Power Lewl N/A instrument Failure Mode Low Temperature Compensation for DP N/A Transmitters Lewi Reference Leg N/A Unique System Description Main stad radiation value from mid range sensor.

m DATA POINT LIBRARY REFERENCE Fl!.E U/3 STACK RAD MONITOR MOD Date 7/20/96 Reactor UnB PE3 Data Feeder N/A NRC ERDS Parameter EFF GAS RAD Point ID -

J654 (A,3)

Plant Spec Point Dest.jption MAIN STACK WRGM L.O RANGE Generic /Cond Descr;ption RadioactMty of Released Gasses Analog /Digtal A

Engr Unts/ Dig States Cl/cc Engr Units Conwrsion N/A Minimum in:tr Range 10

Maximum Instr Range 2x10' Zero Point Reference N/A Reference Point Notes N/A PROC or SENS S

Number of Sensors 1

How Pn ssed N/A Sensor Locations Main Stack Alarm / Trip Set Points None NI Detector Power Supply Cut-off Power Lewl N/A NI Detector Power Supply Turr.-on Power Lewt N/A Instrument Failure Mode Low Temperature Compensation for DP N/A Transmittes Lewi Reference Leg N/A Unique System Description Main stack radiation value from io range sensor.

.l 1

DATA POINT LIBRARY REFERENCE FILE 1

. U/3 STACK RAD MONITOR MOD e

l Date 10/30/96 I

Reactor Unt PE3 Data Feeder N/A NRC ERDS Parameter EFF GAS RAD Point ID SPDS1587 (Change)

Plant Spec Point Description AVG MN STACK RAD-NRW/WlDE RNG Generic /Cond Description RadiosctMty of Released Gasses AnalogOigtal A

Engr Unts/ Dig States Ci/cc Engr Unts Conwrsion N/A Minimum Instr Range 10 8

Ma)dmum Instr Range 10 2ero Point Reference N/A Referera Point Notes N/A PROC or SENS P

t Number of Sensors 3

How Processed Range selected value Sensor Locations Main Stack d

Alarm / Trip Set Points hihl.01, hl10 NI Detector Power Supply Cut-off Po'.oc Lewi N/A Ni Detector Power Supply Tum-on Power Lewi - N/A Instrument Faik.re Mode N/A Temperature Compensation for DP N/A Transmitters Lewi Reference Leg N/A Unique System' Description Range selected value from points J654, J655, J656, main stack lo, mid, and hl range sensors.

4 A