ML20198Q771
| ML20198Q771 | |
| Person / Time | |
|---|---|
| Site: | McGuire, Mcguire |
| Issue date: | 01/05/1999 |
| From: | Rinaldi F NRC (Affiliation Not Assigned) |
| To: | Barron H DUKE POWER CO. |
| References | |
| TAC-MA0471, TAC-MA0472, TAC-MA471, TAC-MA472, NUDOCS 9901070404 | |
| Download: ML20198Q771 (3) | |
Text
._- _____._.
January 5, 1999 Mr. H. B. Barron Vice President, McGuire Site Duke Energy Corporation 12700 Hagers Ferry Road Huntersville, NC 28078-8985
SUBJECT:
EVALUATION OF RESPONSE TO NRC GENERIC LETTER 97-05, " STEAM GENERATOR TUBE INSPECTION TECHNIQUE" (TAC NOS. MA0471 AND MA0472)
Dear Mr. Barron:
The staff has completed its review of your response to Generic Letter 97-05, the focus of "hich was to verify that licensees' steam generator (SG) tube inspection practices were consister.
with the existing regulatory requirements and plant licensing bases. Duke Energy Corporation (DEC) submitted its response on February 24,1998, that included a description and technical bases for allinspection techniques used to size the depth of the SG tube degradation at McGuire Nuclear Station, Units 1 and 2. The staff's review of this response did not identify any concerns with the SG tube inspection techniques employed at McGuire that would indicate that DEC !s not in compliance with the current licensing bases for the McGuire facility.
This completes our effort on DEC's response for McGuire Nuclear Station.
Sincerely, OhIGINAL SIGNED BY:
Frank Rinaldi, Project Manager Project Dire::torate li-2 Division of Reactor Projects - 1/ll Office of Nuclear Reactor Regulation Docket Nos. 50-369 and 50-370 I
a cc: See next page Distribution:
//'
Docket File COgle, Ril Cff1/
PUBLIC LPlisco, Ril PDil-2 Reading PRush JZwolinski ACRS To receive a copy of this document, Indicate in the box: "C" = Copy without attachment / enclosure "E" = Copy with attachment / enclosure "N" = No copy D:PDiter-d_
OFFICE PM:PDil-2 n,
LA:PDil-20 1
NAME FRinaldi.cn Ml dBerry A(t. HBerEw' lDATE
// 4/96
/
if//7M98 l/M/96
/ /98
/ /98
/ /97 DOCUMENT NAMG: G:\\MCGUIRE\\MA0471.WPD OF1FICIAL RECORD COPY 9901070404 990105 PDR ADOCK 05000369 P
PDR V f()Q3g
t@ RfC y".
4 UNITED STATES g
,j NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 2066H001
- p January 5, 1999 Mr. H. B. Barron Vice President, McGuire Site Duke Energy Corporation 12700 Hagers Ferry Road Huntersville, NC 28078-8985 l
t
SUBJECT:
EVALUATION OF RESPONSE TO NRC GENERIC LETTER 97-05," STEAM GENERATOR TUBE INSPECTION TECHNIQUE"(TAC NOS. MA0471 AND MA0472)
Dear Mr. Barron:
The staff has completed its review of your response to Generic Letter 97-05, the focus of which was to verify that licensees' steam generator (SG) tube inspection practices were consistent with the existing regulatory requirements and plant licensing bases. Duke Energy Corporation (DEC) submitted its response on February 24,1998, that included a description and technical bases for allinspection techniques used to size the depth of the SG tube degradation at McGuire Nuclear Station, Units 1 and 2. The staff's review of this response did not identify any concerns with the SG tube inspection techniques employed at McGuire that would indicate that i
DEC is not in compliance with the current licensing bases for the McGuire facility.
l This completes our effort on DEC's response for McGuire Nuclear Station.
Sincerely, fM Frank Rinaldi, Project Manager Project Directorate 11-2 Division of Reactor Projects - l/11 Office of Nuclear Reactor Regulation Docket Nos. 50-369 and 50-370 cc: See next page i
- 1 i
McGuire Nuclear Station cc:
Mr. Paul R. Newton Ms. Karen E. Long LegaI Department (PBOSE)
. Assistant Attorney General Duke Energy Corporation North Carolina Department of 422 South Church Street Justice Charlotte, North Carolina 28201-1006 P. O. Box 629 Raleigh, North Carolina 27602 County Manager of Mecklenburg County L. A. Keller i
720 East Fourth Street Manager - Nuclear Regulatory Charlotte, North Carolina 28202 Licensing Duke Energy Corporation Michael T. Cash 526 South Church Street Regulatory Compliance Manager Charlotte, North Carolina 28201-1006 Duke Energy Corporation McGuire Nuclear Site Regional Administrator, Region ll 12700 Hagers Ferry Road U.S. Nuclear Regulatory Commission Huntersville, North Carolina 28078 Atlanta Federal Center 61 Forsyth Street, S.W., Suite 23T85 J. Michael McGarry, Ill, Esquire Atlanta, Georgia 30303 Winston and Strawn 1400 L Street, NW.
Elaine Wathen, Lead REP Planner Washington, DC 20005 Division of Emergency Management 116 West Jones Street
' Senior Resident inspector Raleigh, North Carolina 27603-1335 c/o U.S. Nuclear Regulatory Commission 12700 Hagers Ferry Road Mr. Richard M. Fry, Director Huntersville, North Carolina 28078 Division of Radiation Protection North Carolina Department of Dr. John M. Barry Environment, Health and Natural Mecklenberg County Resources Department of Environmental 3825 Barrett Drive Protection Raleigh, North Carolina 27609-7721 700 N. Tryon Street Charlotte, North Carolina 28202 Mr. T. Richard Puryear Owners Group (NCEMC)
Mr. Steven P. Shaver Duke Energy Corporation i
Senior Sales Eng;neer 4800 Concord Road Westinshouse Electric Company York, South Carolina 29745 5929 Carnegie Blvd.
Suite 500 L
Charlotte, North Carolina 28209 l
3 I
i
. _..