ATTACHMENT 1 4

SUPPLEMENT 5 to LICENSE AMENDMENT REQUEST DATED December 14,1995 Conformance of Administrative Controls Section 6 to the Guidance of Standard Technical Specifications Appendix A, Technical Specification Pages Marked Up Page as proposed in this Supplement TS 6.0-9 (from December 29,1997 supplement)

-u u

9901220003 980108 PDR ADOCK 05000292' p

PDR 3 s

l t

TS.6,0-9 J.

Explosive Gas and Storace Tank Radioactivity Monitorino Procram

(

This program provides controls for potentially explosive gas mixtures contained in the waste gas holdup system, the quantity of radioactivity contained in gas storage tanks, and the quantity of radioactivity contained in unprotected outdoor liquid storage tanks.

The program shall include:

1. The limits for concentration of oxygen in the waste gas holdup system and a surveillance program to ensure the limits are maintained. Such limits shall be appropriate to the system's design criteria;
2. A surveillance program to ensure that the quantity of radioactivity contained in each gas storage tank is less than or equal to 78,800 curies of noble gases (considered as done equivalent Xe-133); and
3. A surveillance program to ensure that the quantity of radioactivity contained in each of the following tanks shall be limited to 10 curies, excluding tritium and dissolved or entrained noble gases:

Condensate stortje tanks outside temporary tanks

4. The provisions of TS 4.0 are applicable to the Explosive Gas and Storage Tank Radioactivity Monitoring Program surveillance frequencies.

K.

Diesel Puel Oil Testina Procram A diesei fuel oil testing program to implement required testing of both new t tel oil and stored fuel oil shall be established. The program shaA' include sampling and testing requirements, and acceptance cri eria, all in accordance with the limits specified in Table 1 of ASTM t'975-77 when checked for viscosity, water, and sediment. Kdc eptabQ 3yyTo ff neW [f ueTToil[Ta hallfbeidst ei sine QrioMtb a&litionstoTthe(safeghrds] storage;.[tanksf Testinglof fdDiesel fuel oil

$0Nbini88fguapdsjstel.yageXtankstectingshcIlbeperformodht71eay(

?

every 31 days. Ths provisionshofsTST.'62'Meft5ficabAe"tMWe' Diesel

'~

fjer@{12Tes Qnd ProgpamjuneillinnhejfhpquMc3esj.

L.

Technical Specifications Bases Control Program This program provides a means for processing changes to the Bases of these Technical Specifications.

1. Changes to the Bases or the Technical Specifications shall be made under appropriate administrative controls and reviews.

/

l 1

?

k ATTACHMENT 2 4.

f SUPPLEMENT 5 to LICENSE AMENDMENT REQUEST DATED December 14,1995 Conformance of Administrative Controls Section 6 to the Guidance of Stan%rd Technical Specifications Appendix A, Technical Specification Pages Revised Page ao proposed in this Supplement TS,6.0-9 A

1

e s *

-F TS.6.0-9 l

J.

Exolosive Gas and Storace Tank Radioactivity Monitorina Procram This program provides controls for potentially explosive gas mixtures contained in the waste gas holdup system, the quantity of radioactivity contained in gau storage tanks, and the quantity of radioactivity contained in unprotected outdoor liquid storage tanks.

The program shall include:

1. The limits for concentration of oxygen in the waste gas holdup system and a surveillance program to ensure the limits are maintained. Such limits shall be appropriate to the system's design criteria;
2. A surveillance program to ensure that the quantity cf radioactivity contained in each gas storage tank is less than or equal to 78,800 curies of noble gases (considered as dose equivalent Xe-133); and
3. A surveillance program to ensure that the quantity of radioactivity contained in each of the following tanks shall be limited to 10 curies, excluding tritium and dissolved or entrained noble gases:

Conder.aate storage tanks Outside temporary tanks

4. The provisions of TS 4.0 are applicable to the Explosive Gas and Storage Tank Radioactivity Monitoring Program surveillance i

frequencies.

K.

DieceJ Fuel Oil Tentina Procras A diesel fuel oil testing program to implement required testing of both new fuel oil and stored fuel oil shall be established. The program shall include sampling and testing requirements, and acceptance criteria, all in accordance with the limits specified in Table 1 of ASTM D975-77 when checked for viscosity, water, and sediment. Acceptability cf new fuel oil shall be determined prior to addition to the safeguards storage tanks. Testing of diesel fuel oil stered ir. safeguards storage tanks shall be performed at leaat every 31 days The provisions of TS 4.0 are applicable to the Diesel Fuel Oil Testing Program surveillance frequencies.

L.

Technical Soecifications Bases fontr21.Procram This program provides a means for processing changes to the Bases of these Technical specifications.

1. Changes to the Bases or the Technical Specifications shall be made under appropriate administrative controls and reviews.

l

a.

ATTACHMENT 3 SUPPLEMENT 5 LICENSE AMENDMENT REQUEST DATED December 14,1995 Conformance of Adn,inistrative Controls Section 6 to the Guidance of Standard Technical Specifications Final License Amendment Pa2es Note: All of the current Technical Specification Chapter 6 pages were deleted, including Table 6.1 1, by the original submittal and replaced with pages TS.6,01 through TS.6.0-15.

Page Number Source Document Page Number Source Document TS Il Original submittal TS.6.0-2 Supplement (11/25/96)

TS v Supplement (11/25/96)

TS.6,0-3 Supplement 3 TS vill Supplement 4 TS.6.0-4 Supplement (11/25/96)

TS Ix Supplement 4 TS 6.0-5 Supplement 2 TS x Supplement 4 TS.6.0-6 Original submittal TS xl deleted - Supplement 3 TS.6,0 7 Supplement (11/25/96)

TS xil deleted - Supplement 3 TS.6,0-8 Supplement (11/25/96)

TS xlil deleted - Original submittal TS.6.0 9 Supplement 5 TS.3.1 10 Cr:ginal submittal TS.6.010 Supplement 4 TS.3.1 11 deleted - Original submittal TS.6,011 Supplement 4 Table Supplcment 4 TS.6.0-12 Supplement 4 TS.4,1 2B (Page 1 of 2)

TS.6.013 Supplement 4 TS.4.4 1 Supplement 4 TS.6,0-14 Supplement 4 TS.4.61 Original submittai TS.6.n-15 Supplement 4 TS.S.1 1 Original submittal TS.6.0-16 Supplement 4 TS.S.1 2 Original submittal B.3.1 9 deleted - Original submittal TS 0.0-1 Original submittal B.44-3 Supplement 4

_ _ - _ - - - _ _ __-