L OPERATING DATA REPORT DOCKET NO. 50-266

~

DATE: January 2,1998 COMPLETED BY: M. B. Koudelka TELEPHONE: 920-755-6480 OPERATING STATUS

1. UNIT NAME: POINT BEACH NUCLEAR PLANT - UNIT 1

. NOTES

2. REPORTING PERIOD: November - 1997
3. LICENSED THERMAL POWER (MWT): 1518.5
4. NAMEPLATE RATING (GROSS MWE): 523.8
5. DESIGN El ECTRICAL RATING (NET MWE): 497.0
6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE): 509.0
7. MAXIMUM DEPENDABLE CAPACITY (NET MWE): 485.0
8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS:

NA

9. POWER LEVEL TO WHICH RESTRICTED, 'F ANY (NET MWE): NA
10. REASONS FOR RESTRICTIONS, (IF ANY):

NA THIS MONTH YEAR TO DATE CUMULATIVE -

.l l

11. HOURS IN REPORTING PERIOD 720.0 8.016.0 237.288.0
12. NUMBER OF HOURS REACTOR WAS CRITICAL O.0 1,173.6 194,047.5
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 667.3
14. HOURS GENERATOR ON LINE O.0 1,151.0 190.806.0-
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 846.9

? 6. GROSS THERMAL ENERGY GENERATED (MWH) 1,182.0 1.559,513.0 271.053,898.0

17. GROSS ELECTRICAL ENERGY GENERATED O.O 534,720.0 91,625,810.0

]

18. NET ELECTRICAL ENERGY GENERATED (MWH) 0.0 478,899.0 87,335,318.5
19. UNIT SERVICE FACTOR O.0%

14.4 %

80.4 %

20. UNIT AVAILABILITY FACTOR O.0%

14.4 %

80.8 %

21. UNIT CAPACITY FACTOR (USING MDC NET) 0.0%

12.3 %

.75.6%

22. UNIT CAPACITY FACTOR (USING DER NET) 0.0 %

12.0 %

74.1 %

23. UNIT FORCED OUTAGE RATE 100.0 %

85.6 %

4.8%

24. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE, AND DURATION OF EACH):

Refueling, 02/14/98,75 days

25. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP:

December 2,1997 l

DATA REPORTED AND FACTORS CALCULATED AS REQUESTED IN NRC LETTER DATED SEPTEMBER 22,1977 9801200030 900109

~

FDR ADOCK 05000266 R

PDR

=-- -

OPERATING DATA REPORT' DOCKET NO. 50-301 DATE: January 7,1998 COMPLETED 8Y: M. 8. Koudelka TELEPHONE:' 920-755-6480 OPERATING STATUS

1. UNIT NAME: POINT BEACH NUCLEAR PLANT - UNIT 2 NOTES
2. REPORTING PERIOD: November - 1997
3. LICENSED THERMAL POWER (MWT): 1518.5
4. NAMEPLATE RATING (GROSS MWEl: 523.8
5. DESIGN ELECTRICAL RATING (NET MWE): 437.0
6. MAXIMUM DEPENDA8LE CAPACITY (GRO' ~. MWEl: 509.0
7. MAXIMUM DEPENDABLE CAPACITY (NET MWE): 485.0
8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THROUGH 7) SINCE LAST REPORT. GIVE REASONS:

NA

9. POWER LEVEL TO WHICH RESTRICTED, tF ANY (NET MWE): NA
10. REASONS FOR RESTRICTIONS, (IF ANY):

NA THIS MONTH YEAR TO DATE CUMULATIVE

11. HOURS IN REPORTING PERIOD 720.0 8,016.0 222.073.0
12. NUMBER OF HOURS REACTOR WAS CRIT; CAL 358.0 1,897.4 187.885.0
13. REACTOR RESERV5 SHUTDOWN HOURS O.0 0.0 233.9
14. HOURS GENERATOR ON LINE 353.0 1,788.5 185,296.8
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 302.2
16. GROSS THERMAL ENERGY GENERATED IMWH) 523,920.0 2,570,941.0 266.175,948.0
17. GROSS ELECTRICAL ENERGY GENERATED 180,570.0 876,240.0 90,479,550.0
18. NET ELECTRICAL ENERGY GENERATED (MWH) 169,289.5 810,852.0 86,222,435.5
19. UNIT SERVICE FACTOR 49.0 %

22.3 %

83.4 %

20. UNIT AVAILABILITY FACTOR 49.0%

22.3 %

83.6 %

21. UNIT CAPACITY FACTOR (USING MDO NET) 48.5%

20.9 %

79.6 %

22. UNIT CAPACITY FACTOR (USING DER NET) 47.3%

20.4 %

78.1 %

23. UNIT FORCED OUTAGE RATE 51.0 %

29.5 %

1.3 %

24. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE. AND DURATION OF ".ACH):

None

25. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP:

01/23/98 DATA REPORTED AND FACTORS CALCULATED AS REQUESTED IN NRC LETTER DATED SEPTEMBER 22,1977

i, s'

POINT BEACH NUCLEAR PLANT

' DOCKET NO.

50-301-AVERAGE DAILY UNIT POWER LEVEL' UNIT NAME Point Beach) Urst 2 MONTH NOVEMBER -

1997 DATE 12/1/97 COMPLETED BY -

M. B.- Koudels.=

TELEPHONE 920-755-6480'

. AVERAGE' AVERAGE

AVERAGE

' DAILY DAILY DAILY POWER LEVEL POWER LEVEL POWER LhYEL.,

DAY MWe NET DAY MWe NET DAY MWe NET 1

502 11 501

-21

-11 2-500 12 501 22

~-8

'3 500 13 501

. 23 -

-8 ~

4-500 14 502 24' 5 501 15 176 25

'+7 -

6 501 16

-15 26

'3' 7

501 17

-15 27

-3 8

501 18

-16 28

-3 9

501 19

-16 29

-3 10 500 20

-15 30.

. L.-

..