Forwards SE Authorizing Licensee 970311 Request for Use of Code Case N-509 & Relief from ASME Code Section IX Requirements for Exam of Hpcip Studs for Plant,Units 1 & 2
ML20198H227
Person / Time
Site: Brunswick  Duke Energy icon.png
Issue date: 09/08/1997
From: Edison G
NRC (Affiliation Not Assigned)
To: Hinnant C
CAROLINA POWER & LIGHT CO.
Shared Package
ML20198H233 List:
References
TAC-M98734, TAC-M98735, NUDOCS 9709170028
Download: ML20198H227 (3)


Text

_ _ _ _ _ _ _ _ _ - _ _ _ - _ - -

\\

M-M f.o ug/**

gv UNITED STATES g

,j NUCLEAR REGULATORY COMMISSION t

o, WASHINGTON. D.C. 3044Ho01

'%, *.. +,d' September 8,1997 Mr. C. S. Hinnant. Vice' President Carolina Power & Li9ht Company Brunswick Steam Electric Plant l

i Post Office Box 10429 Southport. North Carolina 28461

SUBJECT:

APPROVAL FOR USE OF CODE CASE N-509 AND REllEF FROM ASME CODE.

SECTION IX. REQUIREMENT FOR EXAMINATION OF HIGH PRESSURE COOLANT INJECTION PUMP STUDS - BRUNSWICK STEAM ELECTRIC PLANT. UNITS 1 AND 2 (TAC N05. M98734 AND M98735) f Dear Mr. Hinnant By letter dated March 11. 1997 Carolina Power & Light Company (CP&L) requested approval to use Code Case N-509 " Alternative Rules for the Selection and Examination of Class 1. 2 and 3 Integrally Welded Attachments.

Section XI. Division 1." at the Brunswick Steam Electric Plant (BSEP) Units 1 and 2.

By letter dated A alternative to ASME Code.pril 1.1997. CP&L requested approval of an Section XI. recuirements for examination of BSEP high pressure coolant injection system (FPCI) main pump studs.

The staff has concluded that CP&L's proposal to apply Code Case N-509 as an alternative for the examination of integrally welded attachments is acceptable provided that a minimum 10 percent sample, of all non exempt integrally welded attachments to piping, pumps, and valves, in Class 1. 2. and 3 systems, is examined.

The proposed use of Code Case N-509 provides an acceptable level of quality and safety and is, therefore, authorized pursuant to 10 CFR 50.55a(a)(3)(1). The use of ASME Code Case N-509 is authorized until such time that this Code case is published in a future revision of NRC Regulatory Guide 1.147.

At that time if CP&L intends to continue to implement this Code case, it must follow all provisions in Code Case N-509, with limitations issued in Regulatory Guide 1.147 if any.

Regarding examination of HPCI main pump studs, the staff has determined that the proposed alternative would provide an acceptable level of quality and safety for the remainder of the second 10-year inspection interval.

Therefore, the proposed alternative is authorized pursuant to 10 CFR 50.55a(a)(3)(1).

50EUECElGWB[;Qpy 9709170028 970908 PDR ADOCK 05000324 P

PDR Idbb l ll (! !!{ !!!,!!!,!!,! !!

2 Further details regarding the staff's evaluation and conclusions are contained in the enclosed Safety Evaluation.

Sincerely.

(Original Signed Ily)

Gordon E. Edison. Acting Director Project Directorate 11-1 Division of Reautor Projects - I/II Office of Nuclear Reactor Regulation Docket Nos, 50-325 and 50-324

Enclosure:

Safety Evaluation cc w/ enclosure:

See next page DISTRIBUTION:

' Docket File PUBLIC OGC PD 11-1 RF ACRS BBoger GHill (4)

GTracy JJohnson DOCUMENT NAME: G:\\BRUNSWIC\\BR98734.REL 10 receive a copy of this document, irdicate in the txus "C" = Copy without attachment / enclosure "E" a Copy with attachment / enclosure "N" s No copy OFFICE PN:PD2-1 E

LA:PD2 1 E

OGC

P h,,

NAME Diritrble M EDunningto b

CEdi_so DATE 08/pi /97 08//f/97 08 S 4/97 (ki/ E/97 1

0FFICIAL RECORD COM '

I

Mr. C. S. Hinnant Brunswick Steam Electric Plant Carolina Power & Light Company Units 1 and 2 cc:

Mr. William D. Johnson Ms. Karen E. Long Vice President and Senior Counsel Assistant Attorney General Carolina Power & Light Company State of North Carolina Post Office Box 1551 Post Office Box 629 Raleigh. North Carolina 27602 Raleigh. North Carolina 27602 Mr. Jerry W. Jones. Chairman Mr. Robert P. Gruber Brunswick County Board of Comissioners Executive Director Post Office Box 249 Public Staff - NCUC Bolivia. North Carolina 28422 Post Office Box 29520 Raleigh. North Carolina 27626-0520 Resident Inspector U.S. Nuclear Regulatory Comission Mr. W. Levis 8470 River Road Director Southport. North Carolina 28461 Site Operations Brunswick Steam Electric Plant Regional Administrator. Region 11 Post Office Box 10429 U.S. Nuclear Regulatory Comission Southport North Carolina 28461 Atlanta Federal Center l

61 Forsyth Street. SW. Suite 23T85 l

Atlanta, Georgia 30303 Mr. William H. Crowe, Mayor City of Southport Mr. Mel Fry Acting Director 201 East Moore Street Division of Radiation Protection Southport. North Carolina 28461 1

N.C. Department of Environment.

Health and Natural Resources Mr. Dan E. Sumers 3825 Barrett Dr.

Emergency Management Coordinator Raleigh. North Carolina 27609-7721 New Hanover County Department of Emergency Manaaement Mr. R. P. Lopriore Post Office Box 1525 Plant Manager Wilmington, North Carolina 28402 Carolina Power & Light Company Brunswick Steam Electric Plant Ms. D. B. Alexander Post Office Box 10429 Manager Southport. North Carolina 28461 Performance Evaluation and Regulatory Affairs Public Service Comission Carolina Power & Light Company State of South Carolina 412 S. Wilmington Street Post Office Drawer 11649 Raleigh. North Carolina 27601 Columbia. South Carolina 29211 Mr. K. R. Jury Mr. Milton Shymlock Manager - Regulatory Affairs U. S. Nuclear Regulatory Comission Carolina Power & Light Company Atlanta Federal Center Post Office Box 10429 61 Forsyth Street. SW. Suite 23T85 Southport. NC 28461-0429 Atlanta, Georgia 30303