r August 28, 1997 MEMORANDUM T0:

Seymour H. Weiss, Director Non-Power Reactors and Decommissioning Project Directorate Division of Reactor Program Management FROM:

John W. Hickey, Chief 0r.icinal signed by]

Low-Level Waste and Deco [mmissioning Projects Branch Division of Waste Management, NMSS

SUBJECT:

REVIEW OF THE YANKEE LICENSE TERMINATION PLAN We have completed our review of the Yankee Atomic Electric Company's May 15.

1997, submittal entitled " Yankee License Termination Plan (LTP)." Based on our review, we have developed some comments, and our comments are attached.

Docket No. 50-29 License No. DRP-3

Attachment:

As stated

Contact:

Larry Pittiglio. LLDP/DWM (301) 415-6702 TICKET: LLDP '7/41 Distribution:

Central File NMSS r/f LLPD r/f MBell DGillen PUBLIC RNelson LBell DOCUMENT NAME: S:\\DWM\\LLDP\\CLP\\YLTP.COM OFC

LLDP, C

LLDP 0

LLDPr C

hDP NAME LP

]ip TJoh JFI key 8/lb /97 8/;N/97 8/M97 8/ /97 \\

DATE 0FFICIALRfDDRDCOPY C - COVER E - COVER & ENCLOSURE N = NO COPY ACNW: YES l NO IG

YES NO V Delete file after distribution:

Yes No LS5 YES NO V

IlI VVLif 9709040296 970828 gR ADOCK 0500 9

040009 H ll !! lllll llll! ll

e[E800g#

t UNITED STATES

.ge g

}

NUCLEAR REOULATORY COMMISSION o

y WASHINGTON, D.C. 20656-0001 49,,,. *o August 28, 1997 MEMORANDUM T0:

Seymour H. Weiss. Director Non-Power Reactors and Decommissioning Project Directorate Division of Reactor Program Management FROM:

John W. N. Hickey. Chief - fM

\\

Low-Level Waste and Decommissioning Projects Branch Division of Waste Management, NMSS

SUBJECT:

REVIEW OF THE YANKEE LICENSE TERMINATION PLAN We have completed our review of the Yankee Atomic Electric Company's May 15, 1997. submittal entitled " Yankee License Termination Plan (LTP)." Based on our review. we have developed some comments. and our comments are attached.

Docket No. 50-29 License No DRP-3

Attachment:

As stated

Contact:

Larry Pittiglio, LLDP/DWM (301) 415-6702

August 28, 1997

[

MEMORANDUM TO:

Seymour H. Weiss. Director Non-Power Reactors and Decommissioning Project Directorate Division of Reactor Program Management John W. Hickey Chief 0riginal signed by)

FROM:

Low-level Waste and Deco [mmissioning Projects Branch Division of Waste Management. NMSS

SUBJECT:

REVIEW OF THE YANKEE LICENSE TERMINATION PLAN We have completed our review of the Yankee Atomic Electric Company's May 15.

1997, submittal entitled " Yankee License Termination Plan (LTP)." Based on our review. we have developed some comments, and our comments are attached.

Docket No. 50-29 License No. DRP-3

Attachment:

As stated

Contact:

Larry Pittiglio. LLDP/DWM (301) 415-6702 TICKET: LLDP 7, +1 Distribution:

Central File NMSS r/f LLPD r/f MBell DG111en PUBLIC RNelson LBell 3

DOCUMENT NAME: S:\\DWM\\LLDP\\CLP\\YLTP.COM 0FC LLDP.

C LLDP r

LLDPe C

MDP LRjt glio TJ an J ckey NAME ME 8CC/97 8/3 /97 8 Mj97 8/

/97 0FFICIAL RECORD COPY C - COVER E - COVER & ENCLOSURE N - NO COPY ACNW. YES X

'!0 IG

. YES N0 4 Delete file after distribution:

Yes No LSS : YES NO V

l

____-_am_ _ _. _ _ _ _ _ _ _ _ _ _ _ _ _ _. _ _ _ _ _ _ _ _ _ _ _ _ _. _. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _, _ _ _ _ _ _ _ _, _ _ _ _ _ _ _ _ _ _ _ _

t THE OFFICE OF NUCLEAR MATERIAL SAFETY AND SAFEGUARDS CCMMENTS ON l

YANKEE'S LICENSE TERMINATION PLAN (LTP) 1.0 Section 3.2. 3.3. and 4.2.4 The licensee is proposing to release buildings, demolish the buildings, release the building rubble, then remediate soils areviously under the floors that may be contaminated.

In this case, there may )e contaminated soils that adhere to and are removed with the demolished floor rubble. The licensee needs to discuss how it will verify that demolition rubble is clean if contaminated soils are identified under buildings.

i 2.0 Section 4.2 In Section 4.2.2 the licensee has indicated that the asphalt surfaces will be treated the same way as soil. Asphalt surfaces should be treated under surface criteria.

3.0 Section 2.4.6. and Accendix A. Section 3.2 Section 2.4.6 states that sediment samples will be taken. Also. Section 4.4.5 states that in the pond sediment areas. 30 samples _ per unit will be taken.

However. Appendix A. Section 3.2 states that sediment samples will. not be included in areas affected by monitored and licensed liquid effluent discharges.

Section 3.2 should be revised to-reflect th: c sediment samples will be taken.

t 4.0 Anoendix A. Section 3.1 The licensee committed, in the Decommissioning Environmental Report. December

1993, to use NRC IE Circular 81-07. " Control of Radioactive Contaminated Material" for all materials leaving the Radiation Control Area to ensure that radioactive materials are not inadvertently released from the facility.

This commitment is to limit release of materials from the site to no detectable activity.

The licensee needs to discuss how this commitment is consistent or inconsistent with the release criteria propcsed in this section.

5.0 Aooendix A. Section 4.1.2 This section should be revised to include surveys and samples as an unaffected arealas recommended in NUREG/CR-5849.

6.0 Anoendix A. Section 4.3.1 Section 4.3.2 should be revised to include gridding or a method for referencing measurements back to a specific location.

7.0 Accendix A. Section 4.4.3 This section states that for activated structures and components only exposure

~ rate measurements will be taken. In addition to the exposure rate measurements.

direct measurements and smears should also be taken in accordance with Regulatory Guide 1.86.

Attachment 4

~

2 8,0 Anoendix A. Section 4.4.4 Section 4.3.2 should include a description of the frequency of groundwater samples collected from the observation wells, and a description of what potential t

contaminants the water is being analyzed for.

9.0 Appendix A. Section 4.5.4 and 5 1.3 2

Section 4.5.4 and Section 5.1.3 should be revised to identify the dominant beta-gamma emitters.

-