. -_____ _.. __

- l John J;nkovich Whits _ Sands Rrport PagMJ l l

d' From:

John Jankovich i

To:

Bob Brown, Vivian Campbell Date:

Wed, Nov 25,1998 3:10 PM

Subject:

White Sands Report Vivian, Bob, Steve Baggett and I reviewed the White Sands Army Base Gamma Range Facility report, dated August j

26,1998, and the two operating procedures that you had faxed to us. We found the engineering study in the report well-conducted and the findings to be technically solid. The modified procedures to reduce pressure and terminal velocity correspond to the findings of the study and, consequently, are acceptable.

In our view, two additional precautions may be taken. Specifically, the study found that the sources can safely be used without breakage for their useful life of 5 years or 18,000 cycles. We agree with this conclusion. But as an extra reassurance, we recommend:

1. to keep track of the cycles for each source in order not to exceed the recommended value;
2. to validate that the 18,000 cycle limit is correct not only on the basis of the engineering analysis in the report, but on the basis of real tests as well. l.e. an endurance test up to 18,000 cycles could be run with a dummy source. In such an experiment the facility need not be simulated, one needs only to assure that the dummy source reaches the actual terminal velocity. Validation with the medium size source would also suffice because the safety margin for the large source is higher than for the medium size.

The above are our comments, not requirements for running the facility. We made the comments as recommendations for extra measures. If you have further questions, please contact me. J.Jankovich CC:

SLB l

l l

1 l

9812280225 981110 PDR RC SSD PDR 97/22fsz25

' [C:\\ WINDOWS \\ TEMP \\GW}00001.TMP Pgge__1]

L L

Mail Envelope Properties (365C642E.5B3 : 3 : 23349)

Subject:

White Sands Report Creation Date:

Wed, Nov 25,1998 3:10 PM l

From:

John Jankovich l

L Created By:

TWFN_DO.TWF4_PO:jpj2 Recipients Action Date & Time Post Office ARL_DO.ARL_PO Delivered 11/25 3:10 PM RAB (Bob Brown)

Opened 11/25 3:34 PM VHC (Vivian Campbell)

Opened 11/30 9:39 AM i

Opened 11/30 9:39 AM l^

l Post Office TWFN_DO.twfl_po Delivered 11/25 3:10 PM SLB CC (SLB)

Opened 11/30 5:49 AM Domain. Post Office Delivered Route ARL_DO.ARL_PO 11/25 3:10 PM

/ARL_DO.ARL_PO TWFN_DO.twfl_po 11/25 3:10 PM TWFN_DO.twfl_po l

Files Size Date & Time l

MESSAGE 2316

' Wednesday, November 25,1998 3:10 PM i

I Options Auto Delete:

No Expiration Date:

None Notify Recipients:

Yes Priority:

Standard Reply Requested:

No Return Notification:

None Concealed

Subject:

No Security:

Standard To Be Delivered:

Immediate Status Tracking:

Delivered & Opened i

t

,