Text
-. -.
i i
4 nrog%
{
UNITED STATES p,
NUCLEAR REGULATORY COMMISSION h
E REGION IV
',*****,d[
611 RYAN PLAZA DRIVE. SUITE 400 ARUNGTON, TEXAS 76011-8064 December 15, 1998 1
B. N. Femreite, Vice President Manufacturing Siemens Power Corporation 2101 Horn Rapids Road P.O. Box 130 Richland, Washington 99352-0130
SUBJECT:
NRC INSPECTION REPORT 70-1257/98-05
Dear Mr. Femreite:
On October 30,1998, the NRC completed a routine inspection at your Siemens Power
- Corporation facility in Richland, Washington. The purpose of the inspection was to determine whether actMties authorized by your license were conducted safely and in accordance with NRC requirements. The final exit briefing was held via telephone with members of your staff on November 30,1998.
Areas examined during the inspection were operational safety, operational event review feedback, and management organization and controls. Within these areas, the inspection consisted of a selective examination of procedures and representative records, interviews with personnel, and observation of activities in progress. No violations were identified during the
. inspection. The inspection also included an event reported to the NRC on September 22,1998, involving a failure to remove accumulated solids from dismantled ductwork. During our review of this event and your followup investigation, an unresolved item was identified pending further review by the Office of Nuclear Materials Safety and Safeguards to determine whether a violation occurred. This matter will be reviewed further in NRC Inspection Report 70-1257/98-204.
. In accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of this letter and its enclosure will be placed in the NRC Public Document Room (PDR).
L j
NMED 34819 9812290156 981215 PDR ADOCK 07001257 C
(
l i
l l
Siemens Power Corporation Should you have any questions concerning this inspection, please contact D. Blair Spitzberg at
.(817) 860-8191 or Wayne Britz at ((817) 860-8194.
f Sincerely, l
oss A. Scarano, Director Division of Nuclear Materials Safety Docket No.: 70-1257 License No.: SNM-1227
Enclosure:
NRC Inspection Report 70-1257/98-05 cc w/ enclosure:
L. J. Maas, Manager Regulatory Compliance Siemens Power Corporation 2101 Horn Rapids Road P.O. Box 130 Richland, Washington 99352-0130 Washington Radiation Control Program Director
.. = -
Siemens Power Corporation '
ip E-Mail report.to Document Control Desk (DOCDESK) bec w/ enclosure to DCD (IE07) bec w/ enclosure distribution by RIV:
RIV Regional Administrator LLHowell DBSpitzberg EMcAlpine, Rll DAAyers, Ril PLHiland, Rill CWEmeigh, FCLB/NMSS (8D3)
PWLain, FCLB/NMSS (8D9)
PTing, FCOB/NMSS (8A13)
PHarich, FCOB/NMSS (8A33)
- W L Britz
\\j
- FCDB
- RIV Materials Docket File w/lFS DOCUMENT NAME: Draft: G:\\fcdb.o\\wlb\\80125705.wpd Final: R:\\_DNMS\\80125705.wlb To receive copy of document, Indicate in box: "C" = Copy without enclosures "E" = Copy with enclosures "N" = No copy
_..y RIV:DNMS:FCDB l
C:FCDB DD:DNMS')I D:DNMj/ l Rill:DNMS, j DAAyers:wsw&2M?
WLBritz // l f 4 DBSpitzber$5fLHowell/,1 RA$e6rano 12$/98
"'#JGD, 12/4/98
_12 4/98 12/15/9MT 12f /98 OFFICIAL RECORD COPY U