ML20198D526
| ML20198D526 | |
| Person / Time | |
|---|---|
| Site: | 07000008 |
| Issue date: | 12/14/1998 |
| From: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | |
| Shared Package | |
| ML20198D504 | List: |
| References | |
| 70-0008-98-02, 70-8-98-2, NUDOCS 9812230107 | |
| Download: ML20198D526 (10) | |
Text
{{#Wiki_filter:.-. - -~ l-U.S. NUC' LEAR REGULATORY COMMISSION REGIONlil Docket No: 070-00008 License No: SNM-7 Report No: 070-00008/98002(DNMS) Licensee: Battelle Memorial Institute - Columbus Division Location: 505 King Avenue, Columbus, Ohio Dates: November 16-18,1998 December 11,1998 Inspector: E. L. Kulzer, ClH, CSP, Radiation Specialist Accompanied By: James Webb, Ohio Department of Public Health Approved By: Bruce L. Jorgensen, Chief Decommissioning Branch Division of Nuclear Materials Safety 9812230107 981214 PDR ADOCK 07000008 C PDR L
EXECUTIVE
SUMMARY
BATTELLE MEMORIAL INSTITUTE - COLUMBUS DIVISION NRC Inspection Report 070-00008/98002(DNMS) This was a routine announced inspection and observation of the confirmatory survey conducted by Oak Ridge Institute for Science and Education (ORISE) during which NRC performed radiological surveys in randomly selected rooms (Northwest Highbay Area, Rooms 2074,219, 2107, and Ballmill) located in Battelle Memorial Institute (BMI), Building 2. Wipe samples were collected for independent radiological analysis in the NRC Region ill laboratory. The results of the wipe samples collected were below f 4RC release guidelines for unrestricted use. The inspector observed that ORISE followed their confirmatory survey plan. Characterization surveys and remediation had been performed in these buildings, by BMI and their contractors, in accordance with approved procedures. The licensee's remediation and final surveys appeared to be in compliance with BMI's approved procedures. Two small areas which contained traces of uranium in excess of NRC release guidelines were found in the pipe lip covers in the first floor Room 2074. These areas were remediated immediately. The inspectors' surveys and subsequent laboratory analyses of radiological samples did not identify any residual contamination in excess of the NRC unrestricted release guidelines. No violations of NRC requirements were identified during this inspection. 2
\\ Report Details
1.0 Background
i In 1943, Battelle Memorial Institute (BMI) performed atomic encrgy research and l development while under contract with the Manhattan Engineer District. These programs continued under the Atomic Energy Commission and the Department of Energy. Other nuclear programs were operated under NRC Special Nuclear Materials (SNM) License No. SNM-7. Work conducted under License No. SNM-7 included: evaluations of power and research reactor fuels; post-irradiation examination of fissile material, control rods and structural components; operation of a critical assembly laboratory; and operation of a research reactor. l In 1986, BMI discontinued its nuclear fuel research and began remediation of its facilities such that they would be available for unrestricted use. The decommissioning and decontamination operations were being conducted at the King Avenue and West Jefferson facilities. The Decontamination Plan was approved via an NRC letter dated l December 6,1993. Building 2 had been undergoing remediation and decommissioning i for the past 3 years. The roof in Building 2 has been removed and replaced due to contamination. 2.0 Radiological Surveys a. hLspection Scoce (87104) l The inspectors conducted surface scans in BMI Building 2 using a G-M detector with a pancake probe. Scans included floors, side walls, trenches, and upper beam surfaces near ceilings. In addition to the surveys, the inspectors collected 24 wipes, and performed a direct radiological measurement in each area where a wipe was taken. b. Observations and Findinas Buildina ? During the scanning surveys conducted in Building 2, two elevated areas around pipe lip covers were identified in a trench in Room 2074. The areas were remediated, resurveyed and found to be below NRC release guidelines. The inspectors did not identify any areas which exceeded the NRC unrestricted release in Building 2. The surveys were conducted on the first floor and second floors l (Figures 1-6). Sample Analysis Results l The inspector contacted BMl's Manager of Health, Safety and Environmental Support on l December 11,1998, and advised him that analysis of the wipes collected at the time of the inspection did not identify any removable beta and alpha radiological contamination greater than the NRC release guidelines for unrestricted use. For surface contamination, the NRC guidelines are 1,000 dpm (17 becquerels 2 (Bq)/100 cm ) activity averaged over an area not to exceed one square meter; l 3
l l l i 2 2 3,000 dpm (50 Bq)/100 cm maximum activity over an area not to exceed 100 cm ; and 2 200 dpm (3.4 Bq)/100 cm removable activity. These guidelines are found in the NRC's " Guideline for Decontamination of Facilities and Equipment Prior to Release for Unrestricted Use or Termination of Licenses for Byproduct, Source, or Special Nuclear r l Material," dated August 1987. l l c Conclusions t l The inspectors determined that Building 2 had been remediated below NRC release l guidelines. 3.0 Exit Meeting Summary The inspectors conducted a meeting to discuss preliminary inspection results 'Nith members of licensee management and staff at the conclusion of the inspection on November 18,1998. The licensee acknowledged the findings presented. 1 Attachments: Figures 1 through 6 PARTIAL LIST OF PERSONS CONTACTED L. Davies, Health Physics Supervisor B. Dotson, Battelle Memorial Institute C. Jensen, Radiological Technical Support Manager M. Rubadue, Battelle Memorial Institute i l 1 l l 4
i Figure 1 Highbay Area 1 %F 44 4 Q d ~} 4 u ? l 8 L '~~-- - ' Aas Aas
- Aas
- A24 ' @
Asa (Ass- ' Ass
- Ai4 ' Ata ' A12 ' Att.' Aio ' A9
/ l- + + + + + H ,- + + + + + ) -{ l- + + +y "M 8 i Iy .+ + + + + ++++ M I sesumn pn" ~ ;p6 j - h -+h U 1 .n A+ H 54! - + + + + + + + + + i och H e' + + q + + bOC[+#h + + + + -, 194Y + H,3 ~ ~ ~+++~ + + " + + + + .m 'm 'm 'no 'as ' "^ +++ ++++++++++++4 + ,g},y, ,,,yyj g %++++4 Mm? 58 2 + + + + + + 4 + +9 - + + + + + + + + + 2 + + + 4 + + + + I .+ + + owRm 9e; _2 4 Pa * ~ 4 a kh h ~ hj ()y a-l 1 e m.. .mm m -ww -= w r m -.
l 1 g y.. +
- g. r w r r r.i.7~ r r r r-r [
eg
- . g.... + + + + aq.yg fTi I
% a nW n. ' 9 + g+Q * % gi ra +++ O{ $~)T5 ',, %:ee *
- s,%]i N
tt $T { 4, f :.', h ^ \\ ...x th.1..,....Mk+,f; +y 4, .+ *p p G i +. + 2' ,+ + $+!,9xc.$hblKk:.x:hh'..$ e ,+ ;- q + +.a. +4 y i +[,+ g ++ % s .+ +i N 3 ..+ +- 4 g ,+ m e ++++ e ,Q+ge++g'\\.x..1,;, s g g g 4 G = 3 ~ 4 s g 4
- .y w
.I. T + + + g i j '~ ,7., 3 5--:i:: -sM + +++++ ' + + .h e +
- 9..,,
., + 1 se i n y 3+ g+ ++ '+ '. j ,+ ...; s + +{+ g + g + & + g ' > E* + *k+ + + + b ..;4.ht 4.4t.'J 111 1 I I i 1 3 -- ~- 1:1 .i 1. -i .i-g III 1., -3 ~ Mki$$ -I ?
- l...t 9
.._ m _ _ _ _. _ l l West Wall r 1 Deam I HS
- --HIS
~ G5 -GIS i F5 - -F15 y El E2 E3 H3eam- -EIS 2 - 015 i l -CIS I 01 -B15 / ~ At A2 A3 A4 4 A6 A7 AB A9 10 A11 A12 A13 14 --A15 l iOi . e e e _ i Plilar Pillar I WT 940W m East Wall E N'*" H1 ~ H3 H7 H8 H9 ~ H2 3 S d l c-1 E11 E12 E13 E14 l 14eam { i E15 D15 C15 1 A2 A3 AS 6 A7 A8 A9 A1 11 A12 A13 1 l .k; si i i i i i i i \\: ediar \\ edra'r' n l 'm go g go so i cen Cf6 arfo Characterization not performed due to pilor knowledge of contamination. N-> l BUILDING KA-2 ROOM 2074 (Continued) 1 I I a
t l l l Exit Door II4 11 o Vi ,--r-- r- - TH -A1 A2 A3, A4 A5 A6 AF /^ ^a A10 - - A11 V go.go cfM g + + + & +- e+ + ,_ a,. 3 -e,, f.,,,,,,, 2074 A i i e r_ i _r _ fh-l$ (l ' C13 C11 'C1 Y -{,b ?,- l- - A l- $g to~IutlHr + + + + 4 Arni- +,,,- -+ + + + t + + + + + + + + + + + + +F15 - lo-ta.ut.\\ha.- l + + + + + + + + + + + + +g,3 - a, f. . Trm@ i i F + + + + + + + + + + + +- +is - O ,.e lo-tws Ikg. 2 t + + + + + + + + + + + + +J15 J 3en E {F + + + + + + + + + + + + d+' IY4 udllt on.xPjk+ . lo -G.dj + 8 + + + + + + + + + + + L15 54 itxRjl4s t 4- + - - - 3
+ - + - +.-
+ l lg-30- W y 90~90e % bL+ _.+_ 90-tw etm 4 + - - - + l l + - -E -+-- l + +NIS f NI %j j7 F. +. + +. +. +. +. +. +, +. +, +. - i i i i r-- i i i i e i i i 01 02 03 04 05 06 08 09 010 0 11 012 013 014 015 To 2os 5'3cA VN t BUILDING KA-2 ROOM 2074 en e a l I l
s / y),ab gg6M Floor North Wall I ^ g~ g %t' 'A2 'M 'A4 of 'B2 '83 's4 w -,c C-# +p + ,%%r-A ci + +.+ +cs. gp so -70 cm yg,% % % %- [* \\. South Wall bdk 01 's2 's3 's4 gg 'A1 +A2 +A3 +A4 West Wall et M '85 A *wn 11 'A2 'A3 'M As s . A. C j - ' 7A Horizontals/ Celling" 4 b, A1 A2 A3 M a 0 '70of A C ,+ + +.. a East Wall et \\'ai 'e3 's4 'as 'c1 + + + ooer ~ A1 A3 M D1 02 03 D4 .J ) g, 'l0 -Geefn cesar ct ris. con on ir nc p.rform.d ev.to prk,e knows.de. w atamination. " Final status population swwy not perform d du. to Colling/ Roof r.moval. FNW BUILDING KA.2 ROOM 2110
\\ W Qt bY# go# Floor b North Wall 1 'A2 'A3 ' A4 'A5 A 01 'B2 'B3N' yo 40c@. B1 -9b ~ ' +f7cpr A1 A2 A3 A4 "0 4 4 f_ ^YO~%O & t 1 CS go -Leo e +o, +o, +,+,3 o '# N] $*b South Walp 3 0 -$0CpA t\\-\\ B1 \\'B$ 'B/ C046cM M D ers h A1 A2 4 West Wall i l B1 M 'B4 'BS window f +y' +y +y y 3 e l' Horizontats/Colling"
- s -
A1 'A2 'A3 'A4 u. + + + Bt East Wall Ek '/ 2 'B3 \\ 'B/ '85 C1 Door Door ~ A1 At A3 A5 D1 D2 03 04 l Characterhation on truse not performed due to prior knowledge of contamination. " Final status populatfori survey not performed due to Collingstoof removal DNF BUILDING KA-2 ROOM 2107 _}}