Text
.-_.
gwww__wwwww wwwwwwwwwwwwwwwwwwwwwwwwwww.
azww.wwgl Ig NRC FORM 518 U.S. NUCLEAR cE2ULATORY COMMISSION g
4 nw N
CERTIFICATE OF COMPLIANCE
>i "d FOR RADIOACTIVE MATERIALS PACKAGES U
E.
l.
- b. REVIslON NUMBER
- e. PACKAGE IDENTIMCATION NUMBER d PAGE NUMBER g' 16 CERTU1CATE NUMBER e TUTAL NUMBER PAGES g!
p 9128 7
USA /9128/8(U) 1 3
g
. 2 PRt. AMBLE N
kj a This cemficate is hsued to cemfy that the packaging and conteau desenbed in item 5 below, meets the vpleable safety standards set forth in Title 10. -
N s.
Code of Feders! Regulations, Part 71,
- Packaging and Transportauon of Radsoecuve Material.*
k g
Nl b This cemficate does not reheve the consignor froen comphance 3.th any requirement of the regulations of the U.S. Department of Transportauon or other E
I apphcable regulatory agevies, including the government of any country through or into stuch the package mill be transported, N
I E
I 3 TH13 CERTinCATE 15 ISSUED ON THE B AS!$ OF A SAFETY ANALY515 REPORT OF THE PACKAGE DESIGN OR APPUCATIONg a 135ULD TO rNaaw sad Add'rA
- b. TTT11 AND IDENTIMCATIC,N OF REPORT OR APPUCATION.
4 B';
E, p
Amersham Corporation Amersham Corporation application dated g
lp 40 North Avenue March 9, 1989, as supplemented g
q Burlington, MA 01803 g
El E
71 9128 p
e.DoCxETwUMBER g
g 4 CONDfTIONS g
g This cemfgete is condinonal upon fulfathng the requiremenu of 10 CFR Part 71, as applicable, and the condiw a specified below.
g 99, s E
E g
(a) Packaging fl g
l (1) Model No.: C8 ll A steel encased, uranium shielded source exchanger. The shipping I
a container is approximately 16 inches in diameter,13 inches long and E
Yi 22.5 inches hig1 in its skid mounted configuration. The radioactive E
l
- i scptum at the center of the "S" tube prevents moving the source E
assembly beyond the optimum shielding position. The tube is E.
- i surrounded by depleted uranium metal as shielding material. The E
!i depleted uranium shield assembly is encased in a steel housing. The E
't void space between the depleted uranium shield assembly and the outer E
1 container is filled with a polyurethane foam. The gross weight of E
!i the container is 500 pounds.
El
?i E
?l (2) Drawing *,
E 5
E The packaging is constructed in accordance with Garama Industries E
i 5
Drawir.g Nos. 821 1001 033: 180 01: 191: 821 1005 0080. Rev. A:
E 821 1001 117: 821 1001 128 sheet 1. Rev. 2: 821 1001 128 E
sheet 2; 821-1001 129: 811 1001 212, Rev. A; 811 1001 111, Rev. 2:
E' 1
and 801 1001-159.
E
!i E
E
- i E
N I
E i
E 5l Rl 1
E
- F E
h.
E, EI
- c El I
9801060070 971222-E!
E l
PDft ADOCK 07109128 gl 4
C
- PDR, l
b, g
j.
gl W-(i i
n 1
A M & B 4 1 & 4 4 & & & M 31 311#3 & & E 3 3 @ 3( g & 3 3 m 33m 3 33353. m 33m g g g g g g g g g g
g==---------------
pl #ac,FoRusisA l
co emo e w -
u.s. NUCLEAR REIULAToRY CoaststSSm Dp,' " Page 2 H Certificate Ne 9128 < Revision No. 7 - Docket No. 71 9128-r r
I I
F I
l t
D 5.
'(b) Contents i
B;, -
i D
_(1) Type and form of material-t p
8 r
>1 Cobalt 60 as sealed sources that meet the requirements of g
D; -
' special form radioactive material, i
p; -
i pl (2)~ Maximum quantity of material per package r
p p
200 curies (output) f 5l i
I p'
Output curies are determined in accordance with L
p American National Standard N4321980, " Radiological I
I Safety %r the Design and Construction of Apparatus Dl.
p for Gah.a radiography"
,l I
p 6.
The source shall be secured in the shielded position of the packaging by I
p the safety cap, source assembly and lockbox assembly. The components used l
I l
to secure the source must be fabricated of asterials capable of resisting p!
a 1475'F fire environment for one half hour and maintaining their I
p l
I p'
positioning function. The ball stop of the source assembly must engage p
the locking device. The flexible cable of the source assembly must be of I
I sufficient length and diameter to provide positive positioning of the lp f
p-source at the septum in the shtelded position.-
t
!i:
7.
The can and side plates must be a minimum of 1/4 inch thick carbon steel.
I l
The can and side plates shall be joined by full penetration welds. All l
p n'.
other welds shall be fillet welds having sufficient throat thickness to I
l develop strength equal to or greater than the metals being joined.
L p
f able of resisting the I
The nameplates shall be fabricated of materials cakegibility.
8.
fire test of 10 CFR Part 71 and maintaining their I
i g
9.
Use of packaging fabricated after January 31, 1991 is not authorized.
I 10.
In addition to the rendrements of Subpart G of 10 CFR Part 71:
I f
- accordance with the Operating Procedures.of Section 7.0 of the I
- a. The package.shall be repared for shipment and operated in r
- August 19, 1996, application as supplemented.
l r
,L ll
- b. The package must be maintained in accordance with the Acceptance i
Tests and Maintenance Program of Section 8.0 of the August 19, r
h 1996, application as supplemented.
r f
- 11. The package authorized by this certificate is hereby approved for use L
gL under the general license provisions of 10 CFR 571.12.
i lt
- 12. Expiration date: December 31, 2002.
i I
I e
o I
t I
t' t
i I
l U
g aaaaaaamaaaaaaaaaaaamaa
..,,,,,,,,,,,,,,,,,,,,f
--w-d-e-r g-ee-e g
g..
9-y
.,wi
,-rs q,.
m g-ey%vir--
er.
..-@w m
a.
.r 2
e.--
- ~.~
f-_wwwzwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww lg NRC FORM SICA~
coNDmoNs trannawh U.S. NUCLEAR RE*ULATORY COMMIT $lON
- now-Page 3 Certificate No. 9128 Revision No. 7 - Dor.ket No. 71 9128-6
. p i
p I
I Dl-I D
REFERENCES I
I Amercham Corporatio.n application dated March 9,1989.
l f,
Supplements dated: August 21, and September 23, 1989: February 8, and E
December 6, 1990; and January 29, 1991; and November 6, 1995; and August 19, I
1996; and 'iay 21, 1997.
E D'
E D
FOR THE V.S. NUCLEAR REGULATORY COMMISSION I
3l I
lf 42f+4 l
l CassR.Chappell,!dief p
E ej Package Certification Section d
e Spent Fuel Project Office I
p' Office of Nuclear Material Safety I
bl and Safeguards I
b' I
s' Date:- w -h-99 loc 7 I
s' E
sl E
E E
6 I
nl E
9, E
D, E
B, E
9 E
D, E
4,,
E R;
E D
E j
E, I
- g I
l E
i Di E
9, I
- l E
E i
E B,:
I B'
E n,
E b,
E p;
r:
B, E
b E
b,;
E; D,
E' R
d t
D E
D, i
E kammmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmwat
,pwh gN t
UNITED STATES 6
g
,j NUCLEAR REGULATORY COMMISSION
'C WASHINGTON, D.C. 20665 4001
% ***/
APPROVAL. RECORD Hodel No. C 8 Package Certificate of Compliance No. 9128 Revision No. 7 By application dated November 6,1995, as supplemented, Amersham Corporation
'equested renewal of Certificate of Compliance No. 9128 for the Model No. C 8 package. No cha'vjes in package design or contents were requested. Condition 5(b)(2) of the certificate has been revised to specify that the source strength is given in output curies, consistent with American National Standard N432-1980.
Sections on operating 3rocedures, acceptance tests and maintenance program were reviewed and found to >e adequate. The certificate has been conditioned to require that the Jackage be prepared for shipment, operated and maintained in acenrdance with tie procedures in the supplements dated August 19, 1996, and May 21, 1997.
Amersham does not desire to fabricate additional units of the Model No. C 8 package, and the Safety Analysis Report and the certificate drawings did not specify codes, standards, and procedures for fabrication of the package. The amended certificate retains the previous condition which precludes use of packaging fabricated 6fter January 31, 1991.
The certificate has been renewed for a five year term which expires on December 31, 2002.
M4 Cass R. Chappel Chief Package Certification Section Spent Fuel Project Office
(
Offit.e of Nuclear Material Safety and Safeguards Date: Decenher 22, 1997